HP LC2000r HP Netserver LT 6000 FC Config Guide for Windows NT4.0 Clusters - Page 2

Storage

Page 2 highlights

System software: Navigator version Operating System Service pack distribution units (PDU's) are strongly recommended. L.18.03 or later Microsoft Windows NT Server 4.0, Enterprise Edition SP6A or later SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: Default Boot Order M/S Certified Configuration HP NetServer LT 6000r 550, 700 MHz 2 - 6 4.06.21 PW or later (550 MHz) 4.06.26 PW or later (700 MHz) Any size 128 MB minimum. Must be HP. 3 standard, 3 required for redundancy See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, Embedded A, Embedded B, PCI-6, PCI-5, PCI-4, PCI-3, PCI-2, PCI-1 P2 - Client LAN P4 - Local storage (NetRAID-1Si) P6 -Shared Storage HBA Booted from embedded DAC Storage Local Controller Driver Cabinets (Physical drive location) Disk drives SCSI bus SCSI Ids May use embedded SCSI, embedded DAC, NetRAID-1Si or NetRAID-3Si. For embedded SCSI, use sym_hi.sys version 4.12 or later. For embedded DAC and NetRAID-xSi, use mraidnt.sys version 2.24 SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP (hot swap or fixed) Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared HP Rack Storage/12FC Host Bus Adapter Model No. of controllers Driver RAID level Cabinet RAID arrays Required HP Fibre Channel Host Bus Adapter - HP D8602A 1 Hhba5100.sys 1.12 or later 0,1, 3, 5, 10 HP NetServer Rack Storage/12FC- D5991A Not more than eight physical drives per logical array and not more than eight LUNs are permitted per cluster. 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

2
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
L.18.03 or later
Operating System
Microsoft Windows NT Server 4.0, Enterprise Edition
Service pack
SP6A or later
SPU
Model
HP NetServer LT 6000r
Clock speed
550, 700 MHz
No. of CPUs
2 - 6
BIOS version
4.06.21 PW or later (550 MHz)
4.06.26 PW or later (700 MHz)
CPU cache
Any size
RAM
128 MB minimum.
Must be HP.
No. of power supplies
3 standard, 3 required for redundancy
Local storage
See
Local Storage
below.
I/O slots:
Added cards may be installed in any appropriate slot, keeping in mind the
server’s default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, Embedded A, Embedded B, PCI-6, PCI-5, PCI-4,
PCI-3, PCI-2, PCI-1
M/S Certified
Configuration
P2 - Client LAN
P4 – Local storage (NetRAID-1Si)
P6 –Shared Storage HBA
Booted from embedded DAC
Storage
Local
Controller
May use embedded SCSI, embedded DAC, NetRAID-1Si or NetRAID-3Si.
Driver
For embedded SCSI, use sym_hi.sys
version 4.12 or later.
For embedded
DAC and NetRAID-xSi, use mraidnt.sys version 2.24
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives
Must be HP (hot swap or fixed)
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
HP Rack
Storage/12FC
Required
Host Bus Adapter
Model
HP Fibre Channel Host Bus Adapter - HP D8602A
No. of controllers
1
Driver
Hhba5100.sys
1.12 or later
RAID level
0,1, 3, 5, 10
Cabinet
HP NetServer Rack Storage/12FC- D5991A
RAID arrays
Not more than eight physical drives per logical array and not more than
eight LUNs are permitted per cluster.