EISA nonvolatile RAM., Wrong Accelerator
View all HP ProLiant 4500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 275 highlights
ADU Error Messages Table D-1: Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action Write memory error Data can not be written to the cache memory. This typically means that a parity error was detected while writing data to the cache. This can be caused by an incomplete connection between the cache and the controller. This is not a data loss circumstance. With the system powered down, be sure that the cache board is fully connected to the controller. Wrong Accelerator This may mean that the board was replaced in the wrong slot or was placed in a system previously configured with another board type. Included with this message is a message indicating (1) the type of adapter sensed by ADU, and (2) the type of adapter last configured in EISA nonvolatile RAM. Check the diagnosis screen for other error messages. Run the server setup utility to update the system configuration. HP Servers Troubleshooting Guide D-25