HP ProLiant 800 HP ProLiant BL e-Class Integrated Administrator User Guide - Page 86

REMOVE USER, ALL | <user, name>], SET GROUP, DESCRIPTION, <group, name&gt, <description

Page 86 highlights

Command Line Interface Table 4-3: User Account Commands continued Command Description REMOVE USER [ALL | ] Removes a user from the system If ALL is specified, the command is run for all users except the default system accounts. SET GROUP {DESCRIPTION } Sets a group's description. SET PASSWORD {} Sets the password of the user currently logged into the Integrated Administrator. If a password is not given on the command line, the user is prompted for one. Note: This command is not valid in SCRIPT MODE if password is not specified. Restrictions Only enclosure administrators may execute this command. The is case-sensitive. The "Administrator," "switcha," and "switchb" accounts cannot be removed. Only enclosure administrators may execute this command. The is case-sensitive. The must be 0-20 characters long and can include all alphanumeric characters, the dash, the underscore, and spaces. The default group description is blank. If spaces are part of the contact information, enclose the information in quotes. The must be 3-8 characters long and can include all printable characters. continued HP ProLiant BL e-Class Integrated Administrator User Guide 4-9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228

Command Line Interface
Table 4-3:
User Account Commands
continued
Command
Description
Restrictions
REMOVE USER
[ALL | <user
name>]
Removes a user from the
system
If ALL is specified, the
command is run for all users
except the default system
accounts.
Only enclosure administrators may execute
this command.
The <user name> is case-sensitive. The
“Administrator,” “switcha,” and “switchb”
accounts cannot be removed.
SET GROUP
{DESCRIPTION
} <group
name>
<description
>
Sets a group’s description.
Only enclosure administrators may execute
this command.
The <group name> is case-sensitive. The
<description> must be 0-20 characters long
and can include all alphanumeric
characters, the dash, the underscore, and
spaces.
The default group description is blank.
If spaces are part of the contact
information, enclose the information in
quotes.
SET PASSWORD
{<password>}
Sets the password of the user
currently logged into the
Integrated Administrator.
If a password is not given on
the command line, the user is
prompted for one.
Note:
This command is not
valid in SCRIPT MODE if
password is not specified.
The <password> must be 3-8 characters
long and can include all printable
characters.
continued
HP ProLiant BL e-Class Integrated Administrator User Guide
4-9