HP ProLiant DL380 G3 with MSA500 HP ProLiant Servers Troubleshooting Guide - Page 106
SCSI Port X, Drive ID Y RIS Copies Within This Drive Do Not Match
View all HP ProLiant DL380 G3 with MSA500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 106 highlights
Description: SMART is unable to communicate with the drive, because the cable is not securely connected, or the drive cage connection has failed. Action: 1. Power down the system. 2. Reconnect the cable securely. 3. Restart the system. 4. If the problem persists, replace the cables and connectors as needed. SCSI Port X, Drive ID Y RIS Copies Within This Drive Do Not Match Description: The copies of RIS on the drive do not match. Action: Check for other errors. The drive may need to be replaced. SCSI Port X, Drive ID Y...S.M.A.R.T. Predictive Failure Errors Have Been Detected in the Factory Monitor and Performance Data... ...SOLUTION: Please replace this drive when conditions permit. Description: A predictive failure warning for this hard drive has been generated, indicating that a drive failure is imminent. Action: Replace this drive at the earliest opportunity. Refer to the server documentation for drive replacement information before performing this operation. SCSI Port X, Drive ID Y...S.M.A.R.T. Predictive Failure Errors Have Been Detected in the Power Monitor and Performance Data... ...SOLUTION: Please replace this drive when conditions permit. Description: A predictive failure warning for this hard drive has been generated, indicating a drive failure is imminent. Action: Replace this drive at the earliest opportunity. Refer to the server documentation for drive replacement information before performing this operation. SCSI Port X, Drive ID Y Was Replaced On a Good Volume: (failure message) Description: ADU ("Array diagnostic software" on page 78) found that this drive was replaced, even though no problem occurred with the volume. Action: No action is required. Set Configuration Command Issued Description: The configuration of the array controller has been updated. The array accelerator board may remain disabled until it is reinitialized. Action: Run the server setup utility to reinitialize the array accelerator board. Error messages 106
-
1
-
2
-
3
-
4
-
5
-
6
-
7
-
8
-
9
-
10
-
11
-
12
-
13
-
14
-
15
-
16
-
17
-
18
-
19
-
20
-
21
-
22
-
23
-
24
-
25
-
26
-
27
-
28
-
29
-
30
-
31
-
32
-
33
-
34
-
35
-
36
-
37
-
38
-
39
-
40
-
41
-
42
-
43
-
44
-
45
-
46
-
47
-
48
-
49
-
50
-
51
-
52
-
53
-
54
-
55
-
56
-
57
-
58
-
59
-
60
-
61
-
62
-
63
-
64
-
65
-
66
-
67
-
68
-
69
-
70
-
71
-
72
-
73
-
74
-
75
-
76
-
77
-
78
-
79
-
80
-
81
-
82
-
83
-
84
-
85
-
86
-
87
-
88
-
89
-
90
-
91
-
92
-
93
-
94
-
95
-
96
-
97
-
98
-
99
-
100
-
101
-
102
-
103
-
104
-
105
-
106
-
107
-
108
-
109
-
110
-
111
-
112
-
113
-
114
-
115
-
116
-
117
-
118
-
119
-
120
-
121
-
122
-
123
-
124
-
125
-
126
-
127
-
128
-
129
-
130
-
131
-
132
-
133
-
134
-
135
-
136
-
137
-
138
-
139
-
140
-
141
-
142
-
143
-
144
-
145
-
146
-
147
-
148
-
149
-
150
-
151
-
152
-
153
-
154
-
155
-
156
-
157
-
158
-
159
-
160
-
161
-
162
-
163
-
164
-
165
-
166
-
167
-
168
-
169
-
170
-
171
-
172
-
173
-
174
-
175
-
176
-
177
-
178
-
179
-
180
-
181
-
182
-
183
-
184
-
185
-
186
-
187
-
188
-
189
-
190
-
191
-
192
-
193
-
194
-
195
-
196
-
197
-
198
-
199
-
200
-
201
-
202
-
203
-
204