HP ProLiant SL170s HP ProLiant SL170s G6 Server Maintenance and Service Guide - Page 77
If you have installed a PCI accessory board, verify that the board is firmly seated and any
View all HP ProLiant SL170s manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 77 highlights
If the POST failure is during a routine boot up, check the following: • All external cables and power cables should be firmly plugged in. • The power outlet to the server should be connected and works correctly. • The server and monitor are both turned on. The bicolour status LED indicator on the front panel must be lit up green. • The monitor's contrast and brightness settings are correct. • All internal cables are properly connected and all boards firmly seated. • The processor is fully seated in its socket on the system board. • The cooler assembly is properly installed on top of the processor. • All memory modules are properly installed. • If you have installed a PCI accessory board, verify that the board is firmly seated and any switches or jumpers on the board are properly set. Refer to the documentation provided with the accessory board. • All internal cabling and connections are in their proper order. • If you have changed any switches on the system board, verify that each is properly set. Diagnostic tools and Setup Utilities 77