HP StorageWorks 2/16V HP StorageWorks Fabric OS 5.3.2 release notes (5697-7964 - Page 13

Description, Topic, Management - Proxy

Page 13 highlights

Topic Diagnostics Description • All offline diagnostics commands should be used only when the switch is disabled. • Installing new SFPs during POST may cause POST to fail. Install SFPs only when the switch is online or if the switch is powered off. • When you use the diagnostic commands systemVerification and diagSetBurnin, the switch or Blade faults when the burn-in error log is full. Clear the burn-in log before running systemVerification or diagSetBurnin. • If the ISLs reside on the switch that are not used for routing because they have higher link costs, disable the links before running spinfab. HA Fabric Merge Scalability If there is an already segmented port and backbone devices are exported to an edge fabric, a build fabric/fabric reconfiguration can occur after running haFailover. Ensure that no segmented port exists before upgrading firmware. Do not try to merge fabrics with conflicting domain IDs over a VE_Port. Before merging two fabrics over FC-IP with VE_Ports at each end, HP recommends that all domain ID and zoning conflicts be resolved. • Support for Default Zoning policies has been added to Fabric OS 5.1.0. Typically, when you issue the cfgDisable command in a large fabric with thousands of devices, the name server indicates to all hosts that they can communicate with each other. To ensure that all devices in a fabric do not see each other during a cfgDisable operation, you can activate a Default Zone with policy set to no access. If Default zoning policies show enabled, all cfgEnable/disable commands and zoning changes must be run from a switch in the fabric running Fabric OS 5.1.0/5.2.0a. • In large fabrics with more than 1,000 ports, HP recommends that the MS Platform Database be disabled. The Platform DB must also be disabled before downgrading to earlier versions of Fabric OS. This can be done using the msPLMgmtDeactivate command. FRU insertion The FW_FRU_INSERTED message is displayed twice when a power supply FRU is inserted and powered on. There is no functional impact. System boot Not all Fabric OS services run when the prompt becomes available during boot up. Wait for all the services to come up before using the switch or performing zoning actions. Performance Monitoring If the user tries to save more than 512 monitors using the perfCfgSave command, some of the monitors may be lost. Management - Proxy switches If you using a Fabric OS 4.x switch as an API or SMI-S proxy to manage a 5.1.0 switch, you must be running Fabric OS 4.4.0d. HP StorageWorks Fabric OS 5.3.2 release notes 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22

Description
Topic
All offline diagnostics commands should be used only when the switch is dis-
abled.
Installing new SFPs during POST may cause POST to fail. Install SFPs only when
the switch is
online
or if the switch is powered off.
When you use the diagnostic commands
systemVerification
and
diagSetBurnin
, the switch or Blade faults when the burn-in error log is full.
Clear the burn-in log before running
systemVerification
or
diagSet-
Burnin
.
If the ISLs reside on the switch that are not used for routing because they have
higher link costs, disable the links before running
spinfab
.
Diagnostics
If there is an already segmented port and backbone devices are exported to an
edge fabric, a build fabric/fabric reconfiguration can occur after running
haFailover
. Ensure that no segmented port exists before upgrading firmware.
HA
Do not try to merge fabrics with conflicting domain IDs over a VE_Port. Before
merging two fabrics over FC-IP with VE_Ports at each end, HP recommends that
all domain ID and zoning conflicts be resolved.
Fabric Merge
Support for Default Zoning policies has been added to Fabric OS 5.1.0. Typ-
ically, when you issue the
cfgDisable
command in a large fabric with
thousands of devices, the name server indicates to all hosts that they can
communicate with each other. To ensure that all devices in a fabric do not see
each other during a
cfgDisable
operation, you can activate a Default Zone
with policy set to
no access
. If Default zoning policies show enabled, all
cfgEnable
/
disable
commands and zoning changes must be run from a
switch in the fabric running Fabric OS 5.1.0/5.2.0a.
In large fabrics with more than 1,000 ports, HP recommends that the MS
Platform Database be disabled. The Platform DB must also be disabled before
downgrading to earlier versions of Fabric OS. This can be done using the
msPLMgmtDeactivate
command.
Scalability
The
FW_FRU_INSERTED
message is displayed twice when a power supply FRU
is inserted and powered on. There is no functional impact.
FRU insertion
Not all Fabric OS services run when the prompt becomes available during boot
up. Wait for all the services to come up before using the switch or performing
zoning actions.
System boot
If the user tries to save more than 512 monitors using the
perfCfgSave
command,
some of the monitors may be lost.
Performance Monitoring
If you using a Fabric OS 4.x switch as an API or SMI-S proxy to manage a 5.1.0
switch, you must be running Fabric OS 4.4.0d.
Management — Proxy
switches
HP StorageWorks Fabric OS 5.3.2 release notes
13