HP StorageWorks 4/32 Brocade Error Message Reference Guide v6.1.0 (53-1000600- - Page 376
MS-1009, Message, Probable Cause, Recommended, Action, Severity, supportFtp, supportSave
View all HP StorageWorks 4/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 376 highlights
51 MS-1009 MS-1009 Message , [MS-1009], ,, ERROR, , RLIR event. Switch Port ID is . Device Port Tag is . . Probable Cause A Registered Link Incident Record (RLIR) has been generated for one of the actions clarified by the passed in. The following messages might be displayed: • Exceeded bit error rate threshold • Loss of signal or synchronization • Not operational seq. recognized • Primitive sequence timeout • Unrecognized link incident Recommended Action Persistent RLIR incidents are likely due to SAN hardware problems such as bad cables, small form-factor pluggables (SFPs), etc. It may be necessary to replace hardware if these messages persist. Severity ERROR MS-1021 Message , [MS-1021], ,, ERROR, , MS WARMBOOT failure(FSS_MS_WARMINIT failed. Reason=) Probable Cause Indicates that the Fabric OS state synchronization (FSS) warm recovery failed during WARM INIT phase of a reboot. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR MS-1022 Message , [MS-1022], ,, INFO, , Management Server Platform Service Probable Cause Indicates that Management Server Platform Service is being activated or deactivated. Recommended No action is required. Action Severity INFO 324 Fabric OS Message Reference 53-1000600-02