HP StorageWorks 4/32 Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 140
SwitchEnable or SwitchDisable Mode, External SERDES loopback
View all HP StorageWorks 4/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 140 highlights
2 Note: Enter commands in lowercase only; mixed case is for readability. crossPortTest At each pass, a different data type is used to create the frame from a palette of seven types meaning that if a pass of seven is requested, seven different frames are used in the test. If eight passes, the first seven frames are unique, and the eighth is the same as the first. The data palette of seven are: CSPAT: BYTE_LFSR: CHALF_SQ: QUAD_NOT: CQTR_SQ: CRPAT: RANDOM: 0x7e, 0x7e, 0x7e, 0x7e, ... 0x69, 0x01, 0x02, 0x05, ... 0x4a, 0x4a, 0x4a, 0x4a, ... 0x00, 0xff, 0x00, 0xff, ... 0x78, 0x78, 0x78, 0x78, ... 0xbc, 0xbc, 0x23, 0x47, ... 0x25, 0x7f, 0x6e, 0x9a, ... The crossPortTest command behavior depends on the modes activated. Operands SwitchEnable or SwitchDisable Mode In online mode (in which the switch is enabled prior to executing the crossPortTest command), only ports that are cable loopbacked to ports in the same switch are tested. Ports connected outside of the switch are ignored. To run the crossPortTest command successfully the test must find at least one port (-lb_mode = 1, this is the default) or two ports (-lb_mode = 0) cable loopbacked to each other. If this criteria is not met, one of the following message is displayed: Need at least 1 port(s) connected to run this test. Need at least 2 port(s) cross-connected to run this test. In offline mode (when the switch is disabled prior to executing the crossPortTest command) all ports are assumed to be cable loopbacked to different ports in the same switch. If one or more ports are not connected, the test aborts. Note All ports must be connected using loopback plugs or loopback cables for this test to run correctly in offline mode. The test determines which port is connected to which port transmitting frames. If any ports are not properly connected (improperly seated SFPs or cables, bad SFPs or cables, or improper connection or improper connection of SWL to LWL), the following message is displayed: One or more ports is not active, please double check fibre channel connections on all ports. Since this test includes the media and the fiber cable in its test path, its results combined with the results of portLoopbackTest and spinSilk can be used to determine which components of the switch are faulty. It is also possible to use loopback modes 3 and 5 to further isolate failures; refer to -lb_mode, below. This command has the following operands: -nframes count Specify the number of frames to send. The test will progress until the specified number of frames has been transmitted on each port. The default value is 10. -lb_mode mode Specify the loopback mode for the test. By default, crossPortTest uses mode 1 port loopback. Valid values are: 0 Cable loopback 1 Port loopback (loopback plugs) 2 External (SERDES) loopback 2-106 Fabric OS Command Reference Manual Publication Number: 53-1000240-01