HP StorageWorks 4/64 HP StorageWorks DC and DC04 SAN Backbone Director Switche
HP StorageWorks 4/64 - SAN Switch Manual
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 4/64 manual content summary:
- HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 1
HP StorageWorks DC and DC04 SAN Backbone Director Switches hardware reference guide Part number: 5697-7814 Second edition: February 2009 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 2
2008-2009 Hewlett-Packard Development Company, L.P. © Copyright 2008 Brocade Communications Systems, Incorporated The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 3
16 Rack stability ...17 HP technical support ...17 Customer self repair ...17 Subscription service ...17 HP websites ...18 Documentation feedback ...18 1 HP StorageWorks DC SAN Backbone Director Switch Overview 19 HP StorageWorks DC SAN Director Power Pack 19 Features ...19 Hardware components - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 4
Back up the configuration ...55 4 Monitoring DC SAN Director system components 57 Introduction ...57 Monitoring Director blade status 57 status 64 Monitoring core switch blade (CR8) status 66 Monitoring power supply status 68 Monitoring blower assembly status 69 Monitoring WWN bezel ( - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 5
the DC04 SAN Director in the cabinet 134 Installing the DC04 SAN Director shipping brackets 136 Powering on the DC04 SAN Director 138 Port numbering ...139 Managing cables ...139 Using the optional HP StorageWorks DC SAN Director Inter-Chassis Link (ICL) cable kit 140 8 DC04 SAN Director log in - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 6
up the configuration ...152 9 Monitoring DC04 SAN Director system components 153 Introduction ...153 Monitoring Director blade status 153 status 160 Monitoring core switch blade (CR4S-8) status 162 Monitoring power supply status 164 Monitoring blower assembly status 165 Monitoring WWN bezel - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 7
is correct 205 Cable routing table ...206 A Technical specifications 209 General specifications ...209 System architecture ...210 System size and weight ...213 System blade and FRU weights 214 Facility requirements ...214 Power specifications ...215 DC SAN Director ...215 DC04 SAN Director ...215 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 8
...236 Battery replacement notice 236 Taiwan battery recycling notice 237 Power cords ...237 Japanese power cord notice 237 D Port numbering templates 239 HP StorageWorks DC SAN Backbone Director Switch templates 239 HP StorageWorks DC04 SAN Backbone Director Switch templates 245 Index 251 8 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 9
blade 62 21 Control Processor blade (CP8 65 22 Core switch blade (CR8 67 23 Power supply ...69 24 Blower assembly ...70 25 WWN bezel (logo plate 72 26 Removing or switch blade (CR8 87 32 Power supply ...89 33 Blower assembly ...91 HP StorageWorks DC and DC04 SAN Backbone Director Switches 9 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 10
WWN card 95 35 Optical transceiver (SFP and XFP) extraction tool 97 36 Port side of the DC04 SAN Director (sample FC10-6 Director blade 157 56 FR4-18i router blade 158 58 Control Processor blade (CP8 161 59 Core switch blade (CR4S-8 163 60 Power supply ...165 61 Blower assembly 166 62 WWN - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 11
plate) and WWN card 191 73 Optical transceiver (SFP and XFP) extraction tool 193 74 B-Series MP Router blade (FR4-18i) components 225 75 Class 1 laser product label 231 76 248 85 FC10-6 port blades 249 86 FR4-18i router blades 250 HP StorageWorks DC and DC04 SAN Backbone Director Switches 11 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 12
CP blade LED descriptions 66 11 CR blade LED descriptions 68 12 Power supply LED descriptions 69 13 Blower assembly LED descriptions 70 14 Commands identifying the WWN card status 92 18 WWN card related system log messages 93 19 Critical information checklist 98 20 Cable routing table - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 13
215 48 DC04 SAN Director power specifications 216 49 Power cords ...216 50 DC SAN Director environmental requirements 219 51 DC04 SAN Director environmental requirements 220 52 Supported cable speeds and distances 222 53 Hazardous substances 233 HP StorageWorks DC and DC04 SAN Backbone - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 14
14 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 15
blades • Diagnostics and troubleshooting • Technical specifications • Regulatory compliance and safety notices Intended audience This guide is intended for system administrators and technicians with knowledge of: • Storage area networks (SANs) • HP StorageWorks Fibre Channel enterprise class - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 16
text: Table 1 Blue, underlined text: http://www.hp.com Bold text Element Cross-reference links and e-mail text Text emphasis • File and directory names • System output • Code • Commands, their arguments, and clarifying information or specific instructions. NOTE: Provides additional information. TIP - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 17
names and numbers • Technical support registration number (if applicable) • Product serial numbers • Error messages • Operating system type and revision level • Detailed questions Customer self repair HP customer self repair (CSR) programs allow you to repair your StorageWorks product. If a CSR part - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 18
websites For additional information, see the following HP websites: • http://www.hp.com • http://www.hp.com/go/storage • http://www.hp.com/service_locator • http://www.hp.com/support/manuals • http://www.hp.com/support/downloads Documentation feedback HP welcomes your feedback. To make comments and - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 19
the following information: • "HP StorageWorks DC SAN Director Power Pack" on page 19 • "Features" on page 19 • "Hardware components" on page 20 • "DC Director blades" on page 23 • "B-Series MP Router blade (FR4-18i) overview" on page 223 • "Reliability" on page 24 • "Serviceability" on page 24 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 20
1 Gb, 2 Gb or 4 Gb. 8-Gb SFPs operate at 2 Gb, 4 Gb or 8 Gb.) • Extended Form-factor Pluggable (XFP) optical transceivers (10-Gb/s) • All blades are serviced from the port side of the DC SAN Director. Blowers, power supplies, and power cables are serviced from the non-port side 20 HP StorageWorks DC - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 21
• Redundant AC primary power connections to ensure high availability. Each power supply has its own connector, so the number of primary power connections varies from two comb 2. Core switch blade (CR8) 4. FC8-48 Director blade HP StorageWorks DC and DC04 SAN Backbone Director Switches 21 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 22
side view of the DC SAN Director. 1 2 3 25370a Figure 2 Non-port side of the DC SAN Director (sample configuration) 1. WWN bezel (logo plate) 3. Blower assembly 2. Power supply 22 HP StorageWorks DC SAN Backbone Director Switch Overview - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 23
-18i blade integrates sixteen physical FC SFP ports supporting FCR Services and two physical Gigabit Ethernet (GbE) SFP ports supporting Fibre Channel Over IP (FCIP). The two physical GbE ports can support up to sixteen virtual E_ports. HP StorageWorks DC and DC04 SAN Backbone Director Switches 23 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 24
checking • Power-on self-test (POST) • Dual CP Blades that enable hot, non-disruptive fast firmware upgrades • Each CP Blade contains one serial port and two Ethernet ports, for management and for service. Offline CP Blade diagnostics and remote diagnostics simplify troubleshooting. The standby - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 25
system kernel. These applications include: • Name server • Alias server • Zone server • Simple Network Management Protocol (SNMP) agent • SMI-S compliant API • Syslog auditing • Reliable Commit Service (RCS) • Network Time Protocol ID HP StorageWorks DC and DC04 SAN Backbone Director Switches 25 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 26
Management Information Base (MIB). Fabric OS 6.x supports the latest Fibre Alliance Fibre Channel Management (FCMGMT) and Storage Management two meter copper cables • Two ICL Licenses (one license required for each DC SAN Director) AK862A 26 HP StorageWorks DC SAN Backbone Director Switch Overview - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 27
6 Port 10Gb FC blade (FC10-6) HP StorageWorks B-Series Multi-protocol (MP) Router blade (FR4-18i) Optical transceivers HP 4Gb Short Wave B-Series FC SFP 1 Pack HP 4Gb Long Wave B-Series FC SFP 1 Pack-10km HP 8Gb Short Wave B-Series FC SFP+ 1 Pack HP BLc 10Gb SR XFP Opt Kit HP BLc 10Gb LR XFP Opt Kit - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 28
Channel Cable HP 15 m Multi-mode OM2 LC/SC Fibre Channel Cable HP 30 m Multi-mode OM2 LC/SC Fibre Channel Cable HP 50 m Multi-mode OM2 LC/SC Fibre Channel Cable Part number 221692-B22 221692-B23 221692-B26 221692-B27 221691-B21 221691-B22 221691-B23 221691-B26 221691-B27 28 HP StorageWorks DC SAN - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 29
Powering on the DC Director" on page 42 • "Port numbering" on page 42 • "Managing cables" on page 43 • "Using the optional HP StorageWorks installation time, based on a fully One 1/2-in. socket wrench (to remove pallet bolts) One #2 Phillips screwdriver (for cable management comb) One pallet jack One - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 30
Ethernet addresses: one each for the system parameters 20 minutes Ethernet cabling (optional) for Telnet access. All other configuration parameters are optional. Refer to the HP StorageWorks Fabric OS 6.2.x administrator guide facing either direction, if serviceability and cooling requirements are - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 31
One power cable per power supply is required • Protected by a circuit breaker in accordance with local electrical codes • Supply circuit, line fusing, and wire size kit, accessory kit, packing foam, and anti it remains supported during the HP StorageWorks DC and DC04 SAN Backbone Director Switches 31 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 32
kit includes: • HP StorageWorks DC SAN Backbone Director quick start instructions • ESD grounding straps • Two AC power cords appropriate to the country of installation • Two power cord retainers • RS-232 serial cable 14U rack mount kit (includes rear brackets and bottom support rails) IMPORTANT - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 33
. (1.27 cm) panhead Phillips screw, with glue (torque to 80 in.-lbs, 92 cm-kgs) 0.375 in. (0.953 cm) alignment washer Quantity 1 1 6 6 16 6 16 16 HP StorageWorks DC and DC04 SAN Backbone Director Switches 33 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 34
Figure 3 14U Rack Mount Kit contents 26419a 34 DC SAN Director Installation - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 35
rails adjustable ends installed on the side of the rack on the intake air aisle. 1. Locate the shelf brackets in the 14U Rack Mount Kit. HP StorageWorks DC and DC04 SAN Backbone Director Switches 35 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 36
2. Locate and loosen the adjusting screws on the brackets (see Figure 4, items A and B) to allow for adjustment to cabinet depth. Figure 4 Left and right shelf brackets installed on rails 26420a 36 DC SAN Director Installation - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 37
below the brackets for cable management. 4. Tighten the adjusting screws on the rack mount shelf brackets to a torque of 37 cm-kgs (32 in.-lbs). HP StorageWorks DC and DC04 SAN Backbone Director Switches 37 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 38
of the rack (see Figure 6). 3. If applicable, lock the wheels of the lift. 4. Gently slide the chassis onto the shelf brackets, ensuring that it remains supported during the transfer. 38 DC SAN Director Installation - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 39
the screw heads. 2 1 Figure 6 Positioning the DC SAN Director for installation in a cabinet 1. Rack cabinet (shown without sheet metal) 2. Air-instake side of chassis 26422a HP StorageWorks DC and DC04 SAN Backbone Director Switches 39 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 40
Figure 7 Attaching port side of chassis to rack rails 26423a Replacing the chassis door To reinstall the chassis door: NOTE: The door is not hinged. It installs on the chassis by snapping the four ball studs located on the chassis into the receiving hardware on the door. 1. Align the eight ball - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 41
Director door on chassis ball studs 1. Ball stud on chassis (outside view of door) 3. Ball stud on chassis (inside view of door) 2. Mounting hardware 26425a HP StorageWorks DC and DC04 SAN Backbone Director Switches 41 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 42
type, supplies the required voltage, and is properly grounded. 1. Connect the AC power cords to the power supply assemblies. One to four power cords are required depending on electrical service. 2. Connect the power cords to a power source with voltage of 200 to 240 VAC, 47 to 63 Hz (normally two - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 43
through 5 from bottom to top. • FR4-18i router blade-the sixteen physical FC ports on this blade are service disruption. Route cables down in front of the blades to keep LEDs visible. Leave at least one listing of supported cable speeds and distances. Using the optional HP StorageWorks DC SAN - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 44
1 2 LINK ATTN ICL 1 LINK ATTN ICL 0 3 4 LINK ATTN ICL 0 5 1. Status LED 3. LINK LED 5. ICL connector 26378a Figure 10 ICL connectors on CR8 blade 2. Power LED 4. ATTN LED 44 DC SAN Director Installation - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 45
-chassis link (ICL) connections (configuration 1) 1. Chassis 1 3. Core Processor blades (CP8) 5. ICL connector (ICL 1) 7. ICL cables 2. Core switch blades (CR8) 4. Port blades 6. ICL connector (ICL 0) 8. Chassis 2 HP StorageWorks DC and DC04 SAN Backbone Director Switches 45 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 46
1 2 3 4 5 6 7 8 26373a Figure 12 Inter-chassis link (ICL) connections (configuration 2) 1. Chassis 1 3. Core Processor blades (CP8) 5. ICL connector (ICL 1) 7. ICL cables 2. Core switch blades (CR8) 4. Port blades 6.ICL connector (ICL 0) 8. Chassis 2 46 DC SAN Director Installation - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 47
-chassis link (ICL) connections (configuration 3) 1. Chassis 1 3. Core Processor blades (CP8) 5. ICL connector (ICL 1) 7. ICL cables 2. Core switch blades (CR8) 4. Port blades 6.ICL connector (ICL 0) 8. Chassis 2 HP StorageWorks DC and DC04 SAN Backbone Director Switches 47 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 48
1 2 3 4 5 6 7 8 26375a Figure 14 Inter-chassis link (ICL) connections (configuration 4) 1. Chassis 1 3. Core Processor blades (CP8) 5. ICL connector (ICL 1) 7. ICL cables 2. Core switch blades (CR8) 4. Port blades 6.ICL connector (ICL 0) 8. Chassis 2 48 DC SAN Director Installation - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 49
set by the factory to match the license ID (which is based on the chassis serial number). The WWN can be changed but powered on and that POST is complete by verifying that all power LED indicators on the port, control processor, and core switch blades display a steady green light. HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 50
to connect the SERVICE port on the active CP to a computer workstation. The active CP blade is indicated by an illuminated (blue) LED. NOTE: The SERVICE port is intended primarily passwords, refer to the HP StorageWorks Fabric OS 6.x administrator guide. 50 DC SAN Director log in and configuration - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 51
use these addresses. 3. Set up the CP0 IP address by entering the ipaddrset -cp 0 command: swDir:admin> ipAddrSet -cp 0 Enter the information at the prompts. HP StorageWorks DC and DC04 SAN Backbone Director Switches 51 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 52
an Ethernet connection, you can complete the DC SAN Director configuration using either a serial session, Telnet, or management applications, such as Web Tools or Fabric Manager. To establish an Ethernet connection to the DC SAN Director: 1. Remove the shipping plug from the Ethernet port on the - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 53
one end of an Ethernet cable into the Ethernet port. 3. Connect the other end to an Ethernet 10/100/1000 Base-T LAN. The DC SAN Director can be accessed by remote connection using any of the management tools, such as Telnet, Web Tools . HP StorageWorks DC and DC04 SAN Backbone Director Switches 53 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 54
can be up to 8 ports). The ports and cables used in trunking groups must meet specific requirements. Refer to the HP StorageWorks Fabric OS 6.x administrator guide. 2. Position one of the optical transceivers so that the key is oriented correctly to the port. Insert the transceiver into the port - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 55
as passwords, license keys, and IP addresses in a secure location. NOTE: Passwords are not saved in the configuration file, and are not uploaded during a configUpload. HP StorageWorks DC and DC04 SAN Backbone Director Switches 55 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 56
56 DC SAN Director log in and configuration - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 57
Monitoring DC SAN Director system components This chapter page 64 • "Monitoring core switch blade (CR8) status" on page 66 • "Monitoring power supply status" on page 68 • "Monitoring blower assembly status" on page 69 • " those patterns. HP StorageWorks DC and DC04 SAN Backbone Director Switches 57 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 58
1 2 3 4 1. Power LED 3. FC port 25362a Figure 15 FC8-16 Director blade 2. Status LED 4. Port status LED 58 Monitoring DC SAN Director system components - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 59
1 2 3 4 1. Power LED 3. FC port 25367a Figure 16 FC8-32 Director blade 2. Status LED 4. Port status LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 59 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 60
1. Power LED 3. FC port ! 47 23 46 22 45 21 44 20 ! 47 1 2 43 19 42 18 41 17 40 16 39 15 38 14 37 8 31 7 30 6 29 5 28 4 27 3 26 2 25 1 24 0 25366a Figure 17 FC8-48 Director blade 2. Status LED 4. Port status LED 60 Monitoring DC SAN Director system components - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 61
1 2 3 4 1. Power LED 3. FC port 1. Power LED 3. FC port 25368a Figure 18 FC10-6 Director blade 2. Status LED 4. Port status LED 2. Status LED 4. Port status LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 61 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 62
1. Power LED 3. FC port ! 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 GE0 GE1 ! 1 2 7 6 3 5 4 4 FR4 18i 25359a Figure 19 FR4-18i Director blade 2. Status LED 4. Port status LED 62 Monitoring DC SAN Director system components - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 63
LED is off) LED Blade is either healthy or does not Verify that the power LED is on. have power. Steady amber Blade is faulty. Ensure blade is firmly seated and check status using the portEnable or portCfgPersistentEnable command. HP StorageWorks DC and DC04 SAN Backbone Director Switches 63 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 64
information about how to interpret the LED patterns, see Table 10. 2. Check port blade status by typing slotShow and haShow. 64 Monitoring DC SAN Director system components - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 65
1 2 3 4 5 6 7 8 1. Status LED 3. USB LED 5. Console port (10101) 7. Ethernet port (SERVICE) 26401a Figure 21 Control Processor blade (CP8) 2. Power LED 4. USB port 6. Ethernet port (MGMT) 8. Active CP LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 65 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 66
force or CP blade does not have incom- a persistent Ethernet link speed, type ing power. the ifModeSet command. Steady green Active CP Steady blue No light (LED is off) Ethernet link speed is 100/1000 No action required Mb/s. Active CP blade. No action required Standby CP blade. No action - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 67
1 2 LINK ATTN ICL 1 LINK ATTN ICL 0 3 4 LINK ATTN ICL 0 5 1. Status LED 3. LINK LED 5. ICL connector 26397a Figure 22 Core switch blade (CR8) 2. Power LED 4. ATTN LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 67 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 68
) CP blade is either healthy or Verify that the power LED is on. does not have power. Steady amber CP blade is faulty or the switch Ensure blade is firmly seated and is still booting. switch has completed booting. If LED remains yellow, contact HP Slow-flashing amber (on 2 CP blade is not - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 69
24). The LED patterns may temporarily change during POST and other diagnostic tests; for information about how to interpret the LED patterns, see Table 13. HP StorageWorks DC and DC04 SAN Backbone Director Switches 69 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 70
is also provided. If a blower assembly is absent or faulty, contact HP. 12 26382a Figure 24 Blower assembly 1. Power LED 2. Fault LED Table 13 Blower assembly LED descriptions LED purpose Color Status is faulty. tinues to flash, replace unit. 70 Monitoring DC SAN Director system components - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 71
and are displayed by typing the chassisShow command. Error messages that may indicate problems with a WWN card are summarized in Table 14. Figure 25 displays the WWN EMHIL_FAIL, 2, HIL Error: hilSetFruHistory failed, rc=-3 for SLOT 3 HP StorageWorks DC and DC04 SAN Backbone Director Switches 71 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 72
CP blade Status (above) and Power (below) LEDs 2. CR blade Status (above) and Power (below) LEDs 3. Port blade Status (above) and Power (below) LEDs 4. Slot numbers /CP blade/ CR blade Power Port blade/CP blade/ CR blade Status Steady green Steady amber No light (LED is OFF) Power is OK. Blade is - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 73
can be removed and replaced without special tools. The DC SAN Director can continue 79 • "Replacing a core switch blade (CR8)" on page 86 • "Replacing a power supply" on page 88 • "Replacing a blower assembly" on page 89 • "Replacing HP StorageWorks DC and DC04 SAN Backbone Director Switches 73 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 74
management comb CAUTION: Wear a grounded ESD strap when handling DC SAN Director components. The Director chassis provides a grounding connection above the power connectors. Also, store ESD-sensitive components in antistatic packaging. 74 Replacing DC SAN Director field-replaceable units (FRUs) - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 75
Unscrew and save the four screws holding the comb to the chassis (see Figure 27). Support the comb to prevent it from falling. 3. Remove the cable management comb. Installing a computer • Replacement Director blade or filler panel HP StorageWorks DC and DC04 SAN Backbone Director Switches 75 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 76
blade. Check the power LED, status LED, and port status LED to identify any possible problems. See "Monitoring DC Director system components" on page each cable by its physical port). If multiple blades are being replaced, replace one blade at a time. 7. Ensure that traffic is not flowing through the - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 77
top ejector down, to the off position. This initiates a hot-swap request. 10. Wait for the power LED to turn off in response to the hot-swap request before removing the blade. 11. FC8-16 be installed in slots 1 through 4 and 9 through 12. HP StorageWorks DC and DC04 SAN Backbone Director Switches 77 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 78
, align the flat side of the blade inside the upper and lower rail guides in the slot, and slide the blade into the slot until it is slider switch in the top ejector up, covering the thumb screw. 5. Verify that the power LED on the blade is displaying a steady green light. If it does not turn on - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 79
blade does not have the same firmware as the active CP blade, you must upgrade the new blade to the active CP blade's firmware version. HP StorageWorks DC and DC04 SAN Backbone Director Switches 79 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 80
status LED on the CP blade is amber, or the power LED is not lit. • The CP blade does not system driver messages (FABSYS) • Platform system driver messages (Platform) • EM messages that indicate a problem . Refer to the HP StorageWorks Fabric OS 6.x administrator guide for backup information. - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 81
will require that existing Telnet sessions be restarted. To reboot a single logical switch on this system, use the switchreboot command while logged in to that logical switch. Are you sure you want the CP blades during the replacement. HP StorageWorks DC and DC04 SAN Backbone Director Switches 81 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 82
backing up the configuration files: swDir:admin> configUpload Protocol (scp or ftp) [ftp]: ftp Server Name You can use a serial cable or Telnet, Web Tools, or Fabric Manger. Determine which CP is active synchronized and the failover is complete. 4. Power off the blade by sliding the slider switch - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 83
of the CP blade inside the lower and upper blade guides in the slot. Slide the CP blade into the slot power LED is green. If it is not, ensure that the CP blade has power and is firmly seated and that the ejectors are in the locked position. 6. Connect the cables to the new CP blade. HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 84
includes HA Enabled Heartbeat Up and HA-state in sync. If not, POST is not complete or the CP blades have not achieved redundancy. Wait one or two minutes and re-enter the command until you can verify that redundancy has been achieved. 4. Type slotShow. The command output shows the new - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 85
version has been updated. 13. Pack the faulty CP blade in the packaging provided with the new CP blade, and contact HP for the procedure for returning the faulty blade. 14. Replace the chassis door. See "Installing the chassis door" on page 74. HP StorageWorks DC and DC04 SAN Backbone Director - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 86
faulty: • The status LED on the core switch blade is lit amber, or the power LED is not lit. • The slotShow command does not show that the core switch messages • Generic system driver messages (FABSYS) • Platform system driver messages (Platform) • EM messages that indicate a problem with a core - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 87
blade. Use the grounding connections above the power connectors on the chassis. 1. Open the guides in the slot, and then slide the core switch blade into the slot until it is firmly seated (see Figure 31). 3. Tighten the thumb screw inside each handle using the Phillips screwdriver. HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 88
power and is firmly seated and that the ejectors are in the locked position. 6. Connect to the new core switch blade. 7. Pack one power supply slot at all times to ensure power to the DC SAN Director. 2. Loosen the thumb screw. 3. Pull the handle out and down (see Figure 32). 4. Support the power - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 89
displays a steady green light. 26398a Figure 32 Power supply Replacing a blower assembly IMPORTANT: To ensure continuous adequate cooling blower assembly • Phillips #2 screwdriver Removing a blower assembly To remove a blower assembly: HP StorageWorks DC and DC04 SAN Backbone Director Switches 89 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 90
blower assembly, verify that the other blower assemblies are functioning correctly. The power LEDs should be steady green. 2. Use the screwdriver to loosen the captive screws at the top and bottom of blower assembly. 3. Support the blower assembly from underneath. Use the handle to remove the blower - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 91
HyperTerminal for Windows systems or TIP for Solaris systems) How to Power or Status LEDs on WWN card (beneath logo plate) indicate a problem • Problems viewing or modifying the data stored on the WWN card, see Table 17 • Error messages regarding WWN units #1 or #2, see Table 18 HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 92
off) Card is faulty. Card is okay. No action required Check card. No action required NOTE: If a status LED on the WWN bezel flashes, the power LED on the WWN bezel also flashes, for increased visibility. 2. Check the WWN card status using the commands listed in Table 17. Difficulty retrieving or - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 93
INFO, , FRU WWN # insertion detected. WWN unit fails to power on , [EM-1004], ,, CRITICAL, , WWN # failed to power on WWN unit you wish to continue [y/n]?" to display; then type y. HP StorageWorks DC and DC04 SAN Backbone Director Switches 93 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 94
process to be completed. If this process is not complete due to a power cycle, or CP failover, please follow the recovery procedure in Core Switch WWN Backing up WWN card data, please wait about 25 seconds for further instruction. Please install the new FRU now. If this session lost for any reason, - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 95
CAUTION: Wear a grounded ESD strap when handling the WWN card. Use the grounding connections above the power connectors on the chassis. 1. Unpack the new WWN card and save the packaging for the faulty WWN on the chassis (see Figure 34). HP StorageWorks DC and DC04 SAN Backbone Director Switches 95 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 96
card installation to begin functioning. 7. Pack the faulty WWN card in the install an SFP or XFP, position one of the transceivers so that the tool (see Figure 35). The extraction tool is designed to remove transceivers from blades where the space is limited. To use the extraction tool, slide the tool - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 97
SFP and XFP) extraction tool Replacing the DC SAN must be removed from the fabric and powered off to perform this procedure. Contact HP if you have any questions about whether the for Windows systems or TIP for Solaris systems), required only if serial console session used HP StorageWorks DC and - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 98
troubleshoot the chassis, following the list below, and contact your support guides that prevents correct installation of a blade. • Bent or damaged connectors on the backplane (the surface inside the chassis to which the blades connect). • One or more components (such as a power Reference Manual. Use - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 99
Reference. rsl8-st03-dcx-1:admin> configupload Protocol (scp or ftp) [ftp]: ftp Server Name or IP Address [host]: 123.123.123.123 User Name [user]: Admin24 File Name [config.txt]: config-switch0.txt Password: Upload complete rsl8-st03-dcx-1:admin> HP StorageWorks DC and DC04 SAN Backbone Director - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 100
listed is the same as the chassis serial number. rsl8-st03-dcx-1:admin> chassisshow Chassis Backplane Revision: 1F SW BLADE Slot: 1 Header Version: Power Consume Factor: Factory Part Num: Factory Serial Num: Manufacture: Update: Time Alive: Time Awake: 2 -50 60-0001532-03 KP000000195 Day: 1 Month - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 101
CHASSIS/WWN Unit: 1 Header Version: Power Consume Factor: Factory Part Num: Factory Serial Num: Manufacture: Update: Time Alive: Time Awake: (in same Name Enet IP Addr FC IP Addr Name rsl8-st03-dcx-1:admin> HP StorageWorks DC and DC04 SAN Backbone Director Switches 101 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 102
longer depending on the size of the SAN. This file provides a backup of all the information that might be required by Technical Support. The information can sysshutdown This command will shutdown the operating systems on your switch. You are required to power-cycle the switch in order to restore - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 103
CP8)" on page 82). 5. Remove the power supplies or filler panels (see "Removing a power supply" on page 88). 6. Remove the plastic bag from around the chassis. Save the packing materials for use when returning the old chassis. d. Leave HP StorageWorks DC and DC04 SAN Backbone Director Switches 103 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 104
correct level. If installing the chassis in a cabinet, follow the instructions provided by the rack kit manufacturer. Installing components into the new state. 11. Verify that the DC SAN Director is powered on and POST is complete (all power LED indicators on the port, control processor, and core - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 105
rsl8-st03-dcx-1:root> 3. Verify that the chassis serial number has been entered correctly by typing chassisShow at the prompt. Verifying that the system is operating correctly To verify that the DC SAN Director is operating correctly: HP StorageWorks DC and DC04 SAN Backbone Director Switches 105 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 106
1. Log in to the DC SAN Director as admin: rsl8-st03-dcx-1:admin> login login: admin password: xxxxxxxx rsl8-st03-dcx-1:admin> 2. Type slotShow command and verify that all the installed cards are detected and that their status is operational (enabled). rsl8-st03-dcx-1:admin> slotShow Slot Blade - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 107
Gateway Address: 10.32.40.1 Backplane IP address of CP0 : 10.0.0.5 Backplane IP address of CP1 : 10.0.0.6 rsl8-st03-dcx-1:admin>rsl8-st03-dcx-1:admin> HP StorageWorks DC and DC04 SAN Backbone Director Switches 107 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 108
the other ends to an Ethernet 10/100 Base-T LAN, if not already connected. WARNING! The using any of the available management tools, such as Telnet or Web Tools. Ensure that the DC SAN refer to the HP StorageWorks Fabric OS 6.2.x administrator guide. a. Position one of the transceivers - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 109
unintentional changes to the DC SAN Director or fabric. • If there are any mechanical problems, try reseating the associated component. • If the configuration information is not correct for -1:admin> • If other issues exist, contact HP. HP StorageWorks DC and DC04 SAN Backbone Director Switches 109 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 110
Cable routing table Table 20 is a 48-port template for a cable-routing table. Expand the table for the number of ports in the DC SAN Director. Table 20 Cable routing table for DC SAN Director (48 ports shown) Slot/port Slot Port Cable labels Switch end Device end Connected device Slot/port - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 111
Slot/port Slot Port 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Cable labels Switch end Device end Connected device Slot/port of device HP StorageWorks DC and DC04 SAN Backbone Director Switches 111 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 112
112 Replacing DC SAN Director field-replaceable units (FRUs) - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 113
in a Storage Area Network (SAN). The HP StorageWorks DC04 SAN Backbone Director Switch satisfies the most demanding Reliability, Availability, and Serviceability (RAS), performance, and scalability requirements, while delivering investment protection, interoperability, and fabric-based intelligence - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 114
) • 6-port, 10-Gb/s blades (FC10-6) • Modular hot-swappable application blades: • FR4-18i, 18-port (16 FC + 2 GbE), up to four blades per chassis, supporting FCR Services and FCIP • Modular hot-swappable field replaceable units (FRUs): • Two blower assemblies • Two 100 to 240 VAC power supplies • At - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 115
blade and power supply through LEDs • 4-Gb and 8-Gb Small Form-factor Pluggable (SFP) optical transceivers (4-Gb SFPs operate at 1 Gb, 2 Gb or 4 Gb. 8-Gb SFPs operate at 2 Gb, 4 Gb or 8 Gb.) • Extended Form-factor Pluggable (XFP) optical transceivers (10-Gb/s) • All blades are serviced from the - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 116
blade (CP8) 2. Core switch blade (CR4S-8) 4. Exhaust Vent Figure 37 Port side of the DC04 SAN Director with the port side exhaust kit installed 116 HP StorageWorks DC04 SAN Backbone Director Switch Overview - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 117
without the port side exhaust kit installed. Figure 38 Non-port side of the DC04 SAN Director (sample configuration) 1. WWN bezel (logo plate) 3. Blower assembly 2. Power supply HP StorageWorks DC and DC04 SAN Backbone Director Switches 117 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 118
SAN Director, and the DC04 SAN Director. A 6-port Director blade supporting 10-Gb/s port speed. Blade provides 10-Gb/s ISLs. This Director blade is compatible with the 4/256 SAN Director, the DC SAN Director, and the DC04 SAN Director. 118 HP StorageWorks DC04 SAN Backbone Director Switch Overview - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 119
for management and for service. • Standby CP Blade to monitor diagnostics to ensure it is operational, in case a failover is required. • Offline CP Blade diagnostics and remote diagnostics to simplify troubleshooting • Bus monitoring and control of blades and other FRUs HP StorageWorks DC and DC04 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 120
API • Syslog auditing • Reliable Commit Service (RCS) • Network Time Protocol (NTP) • Tasks to manage address assignment, routing, link initialization, fabric initialization, link shutdown, DC04 SAN Director shutdown, and the user interface. 120 HP StorageWorks DC04 SAN Backbone Director Switch - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 121
(MUAs). Up to 255. Event auditing Role-Based Access Controls (RBACs) Change tracking Administrative domains/ protocol and SNMP. All management interfaces, such as Telnet, Web Tools, standards compliant SMI-S, and Management Server, support a "port N within blade M" naming scheme. HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 122
Storage array environments only. NOTE: Contact your local HP representative for information on exact Fabric OS versions supported. T4401A HP StorageWorks MP Blade Performance Extension LTU-Activates the high performance extension services for either IP or FC connectivity in the B-Series MP Router - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 123
6 Port 10Gb FC blade (FC10-6) HP StorageWorks B-Series Multi-protocol (MP) Router blade (FR4-18i) Optical transceivers HP 4Gb Short Wave B-Series FC SFP 1 Pack HP 4Gb Long Wave B-Series FC SFP 1 Pack-10km HP 8Gb Short Wave B-Series FC SFP+ 1 Pack HP BLc 10Gb SR XFP Opt Kit HP BLc 10Gb LR XFP Opt Kit - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 124
Accessory HP 50 m Multi-mode OM2 LC/SC Fibre Channel Cable Part number 221691-B27 124 HP StorageWorks DC04 SAN Backbone Director Switch Overview - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 125
Powering on the DC04 Director" on page 138 • "Port numbering" on page 139 • "Managing cables" on page 139 • "Using the optional HP StorageWorks required for each, based on a fully populated One 1/2-in. socket wrench (to remove pallet bolts) One #2 Phillips screwdriver (for cable management comb) One - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 126
power cables and powering on the DC04 SAN Director 20 minutes Power system parameters 20 minutes Ethernet cabling (optional) for Telnet access. All other configuration parameters optional. Refer to the HP StorageWorks Fabric OS 6.2.x administrator guide provided that serviceability and cooling - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 127
• Supply circuit, line fusing, and wire size adequate to the electrical rating on the chassis the power cords TIP: To maximize fault tolerance, connect each power cord to a separate power source packing foam, and antistatic plastic from the chassis and set aside. HP StorageWorks DC and DC04 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 128
(included based on customer HP StorageWorks product documentation • ESD grounding strap • RS-232 serial cable, with an adapter at one end to provide an RJ-45-style connector IMPORTANT: Order SFP transceivers separately. The DC04 SAN Director supports section provides instructions for installing - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 129
cabinets that have rails with square holes 8 H Alignment washer for cabinets that have rails with square holes 12 I 6-32 x 0.635 cm (0.25 in.) Phillips screw 2 HP StorageWorks DC and DC04 SAN Backbone Director Switches 129 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 130
in Table 28 when tightening screws that secure the rack mount kit and DC04 SAN Director to the equipment cabinet. Table 28 Torque requirements Screw size 6-32 x .635 cm (0.25 in. ) Phillips screw 10-32 x 1.60 cm 0(.63 in.) Phillips screw Torque 10 cm-kg (8.75 in.-lbs) 36.86 cm - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 131
Installing the cabinet hardware 1. Position the DC04 SAN Director in the equipment cabinet so that the non-port side has access to cool intake air. HP StorageWorks DC and DC04 SAN Backbone Director Switches 131 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 132
2. Install the mounting nuts in the cabinet rail locations shown in Figure 40. These nuts secure the 10-32 screws that mount the port-side exhaust kit shelf and DC04 SAN Director to the cabinet. • For rails with round holes-Install the clip nuts (F in Figure 39). • For rails with square holes- - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 133
the shelf to a length of 68.58 to 78.74 cm (27 to 31 inches) to accommodate the cabinet size. To lengthen or shorten the shelf, loosen the four 6-32 screws in the four slots on the shelf (I-4 42. Figure 42 Installing the air-duct assembly HP StorageWorks DC and DC04 SAN Backbone Director Switches 133 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 134
of 68.58 to 78.74 cm (27 to 31 inches) to accommodate the cabinet size. To lengthen or shorten the top-rail assembly, loosen the two 6-32 screws (I-3 in secure the top-rail assembly to the air-duct assembly with two 6-32 screws, one screw on each side of the air-duct assembly (I-1 and I-2 in Figure - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 135
Table 28, page 130. Figure 44 Installing the DC04 SAN Director in the cabinet 6. Reinstall the chassis door. See Installing the chassis door, page 170. HP StorageWorks DC and DC04 SAN Backbone Director Switches 135 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 136
7. Install the cable management finger assembly. See Installing a cable management finger assembly, page 171. Installing the DC04 SAN Director shipping brackets This section describes how to install the DC04 SAN Director shipping brackets. (See Figure 45). These brackets are required when the DC04 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 137
Figure 45 DC04 SAN Director shipping brackets (left side) Figure 46 Installing the shipping brackets on the DC04 SAN Director HP StorageWorks DC and DC04 SAN Backbone Director Switches 137 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 138
the required voltage, and is properly grounded. To power on the DC04 SAN Director: 1. Connect the AC power cords to the power supply assemblies. One to four power cords are required, depending on electrical service. 2. Connect the power cords to a power source with voltage of 200 to 240 VAC, 47 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 139
power switches on the power supplies to ON (I). The AC power switches light green when switched on and power is supplied. 4. The DC04 SAN Director performs a Power-on Self-Test (POST) each time it is powered FR4-18i router blade-The HP StorageWorks DC and DC04 SAN Backbone Director Switches 139 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 140
. Figure 48 Vertical cable management finger assemblies Using the optional HP StorageWorks DC SAN Director Inter-Chassis Link (ICL) cable kit You can purchase the optional HP StorageWorks DC SAN Director Inter-Chassis Link (ICL) cable kit, HP part number AK862A. The kit increases the number of ports - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 141
long as the left-to-right (top-to-bottom) rule is followed. 1. Status LED 3. LINK LED 5. ICL connector Figure 49 ICL connectors on CR4S-8 blade 2. Power LED 4. ATTN LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 141 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 142
Figure 50 DC04 SAN Director ICL cabling 1. Chassis 1 2. Core Switch blades (CR4S-8) 3. Control Processor blades (CP8) 4. Port blades 5. ICL connector (ICL1) 6. ICL connector (ICL 0) 7. ICL cables 8. Chassis 2 142 DC04 SAN Director Installation - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 143
SAN Director chassis 2. Core Switch blades (CR4S-8) 3. Control Processor blades (CP8) 4. Port blades 5. ICL connector (ICL1) 6. ICL connector (ICL 0) 7. ICL cables 8. DC SAN Director chassis HP StorageWorks DC and DC04 SAN Backbone Director Switches 143 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 144
144 DC04 SAN Director Installation - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 145
DC04 SAN Director WWN is initially set by the factory to match the license ID (which is based on the chassis serial number). The WWN can be changed but the license ID cannot be modified. connection and log on to the DC04 SAN Director: HP StorageWorks DC and DC04 SAN Backbone Director Switches 145 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 146
all power LED setting of the IP address and for service purposes. 3. Access the DC04 SAN Director systems: Bits per second-9600 Databits-8 Parity-None Stop bits-1 Flow control-None For most UNIX systems HP StorageWorks Fabric OS 6.2.x administrator guide. 146 DC04 SAN Director log in and - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 147
these addresses. 3. Set up the CP0 IP address by entering the ipaddrset -cp 0 command: swDir:admin> ipAddrSet -cp 0 Enter the configuration information at the prompts. HP StorageWorks DC and DC04 SAN Backbone Director Switches 147 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 148
(LAN). By establishing an Ethernet connection, you can complete the DC04 SAN Director configuration using either a serial session, Telnet, or management applications, such as Web Tools or Fabric Manager. 148 DC04 SAN Director log in and configuration - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 149
1000 Base-T LAN. The DC04 SAN Director can be accessed by remote connection using any of the management tools, such as Telnet, Web Tools unique domain ID. The domain ID can be manually set using the configure command or can be HP StorageWorks DC and DC04 SAN Backbone Director Switches 149 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 150
However, because the date and time are used for logging, error detection, and troubleshooting, they should be set correctly. Setting the date To set the date: interpreted as 1970 through 1999, and values less than 70 are interpreted as 2000-2069) For example: switch:admin> date Fri Sep 26 17:01:48 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 151
can be up to 8 ports). The ports and cables used in trunking groups must meet specific requirements. Refer to the HP StorageWorks Fabric OS 6.2.x administrator guide. 2. Position one of the optical transceivers so that the key is oriented correctly to the port. Insert the transceiver into the port - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 152
the licenseIdShow command. The licenseShow and licenseIdShow commands must be typed through the active CP blade. Refer to the HP StorageWorks Fabric OS 6.2.x administrator guide. Backing up the configuration Save all key configuration data for the DC04 SAN Director, including license key information - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 153
Monitoring DC04 SAN Director system components This chapter 160 • "Monitoring core switch blade (CR4S-8) status" on page 162 • "Monitoring power supply status" on page 164 • "Monitoring blower assembly status" on page 165 • patterns. HP StorageWorks DC and DC04 SAN Backbone Director Switches 153 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 154
1. Power LED 3. FC port Figure 52 FC8-16 Director blade 2. Status LED 4. Port status LED 154 Monitoring DC04 SAN Director system components - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 155
1. Power LED 3. FC port Figure 53 FC8-32 Director blade 2. Status LED 4. Port status LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 155 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 156
1. Power LED 3. FC port Figure 54 FC8-48 Director blade 2. Status LED 4. Port status LED 156 Monitoring DC04 SAN Director system components - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 157
1. Power LED 3. FC port Figure 55 FC10-6 Director blade 2. Status LED 4. Port status LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 157 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 158
1. Power LED 3. FC port Figure 56 FR4-18i router blade 2. Status LED 4. Port status LED 158 Monitoring DC04 SAN Director system components - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 159
LED is off) LED Blade is either healthy or does not Verify that the power LED is on. have power. Steady amber Blade is faulty. Ensure blade is firmly seated and check status using the portEnable or portCfgPersistentEnable command. HP StorageWorks DC and DC04 SAN Backbone Director Switches 159 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 160
information about how to interpret the LED patterns, see Table 31. 2. Check port blade status by typing slotShow and haShow. 160 Monitoring DC04 SAN Director system components - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 161
1. Status LED 3. USB LED 5. Console port (10101) 7. Ethernet port (SERVICE) 2. Power LED 4. USB port 6. Ethernet port (MGMT) 8. Active CP LED Table 31 describes the CP blade LED patterns and the recommended actions for those patterns. HP StorageWorks DC and DC04 SAN Backbone Director Switches 161 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 162
force or CP blade does not have incom- a persistent Ethernet link speed, type ing power. the ifModeSet command. Steady green Active CP Steady blue No light (LED is off) Ethernet link speed is 100/1000 No action required Mb/s. Active CP blade. No action required Standby CP blade. No action - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 163
1. Status LED 3. LINK LED 5. ICL connector Figure 59 Core switch blade (CR4S-8) 2. Power LED 4. ATTN LED HP StorageWorks DC and DC04 SAN Backbone Director Switches 163 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 164
) CP blade is either healthy or Verify that the power LED is on. does not have power. Steady amber CP blade is faulty or the switch Ensure blade is firmly seated and is still booting. switch has completed booting. If LED remains yellow, contact HP Slow-flashing amber (on 2 CP blade is not - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 165
61). The LED patterns may temporarily change during POST and other diagnostic tests; for information about how to interpret the LED patterns, see Table 34. HP StorageWorks DC and DC04 SAN Backbone Director Switches 165 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 166
assembly is also provided. If a blower assembly is absent or faulty, contact HP. Figure 61 Blower assembly 1. Power LED 2. Fault LED Table 34 Blower assembly LED descriptions LED purpose Color Status is faulty. tinues to flash, replace unit. 166 Monitoring DC04 SAN Director system components - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 167
and are displayed by typing the chassisShow command. Error messages that may indicate problems with a WWN card are summarized in Table 35. Figure 62 displays the WWN EMHIL_FAIL, 2, HIL Error: hilSetFruHistory failed, rc=-3 for SLOT 3 HP StorageWorks DC and DC04 SAN Backbone Director Switches 167 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 168
Figure 62 WWN bezel (logo plate) 168 Monitoring DC04 SAN Director system components - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 169
without special tools. The switch blade (CR4S-8)" on page 181 • "Replacing a power supply" on page 184 • "Replacing a blower assembly" Support the door to prevent it from falling. 2. Gently pull the door straight out from the chassis until it snaps out of the ball studs on the chassis. HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 170
CAUTION: Wear a grounded ESD strap when handling DC04 SAN Director components. The DC04 SAN Director chassis provides a grounding connection above the power connectors. Also, store ESD-sensitive components in antistatic packaging. To remove the cable management comb: 1. Rearrange the cables around - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 171
the three screws holding the finger assembly to the rack upright (see Figure 64). Support the assembly to prevent it from falling. 3. Remove the cable management finger assembly only) transceivers (as needed) • Optical cables (as needed) HP StorageWorks DC and DC04 SAN Backbone Director Switches 171 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 172
blade. Check the power LED, status LED, and port status LED to identify any possible problems. See "Monitoring DC04 Director system components" on each cable by its physical port. If multiple blades are being replaced, replace one blade at a time. 7. Ensure that traffic is not flowing through the - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 173
strap when handling a blade. Use the grounding connections above the power connectors on the chassis. 1. Orient the blade so that the ports are at the front of the chassis and the flat side of the blade is on the left. See Figure 65. HP StorageWorks DC and DC04 SAN Backbone Director Switches 173 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 174
, align the flat side of the port blade inside the left and right rail guides in the slot, and slide the blade into the slot until it is firmly in the left ejector to the left, covering the thumb screw. 5. Verify that the power LED on the port blade is displaying a steady green light. If it does not - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 175
blade replacement: • ESD grounding strap • Workstation computer • Serial cable • IP address of an FTP server for backing up the DC04 SAN Director configuration • Phillips #2 screwdriver HP StorageWorks DC and DC04 SAN Backbone Director Switches 175 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 176
status LED on the CP blade is amber, or the power LED is not lit. • The CP blade does not system driver messages (FABSYS) • Platform system driver messages (Platform) • EM messages that indicate a problem Refer to the HP StorageWorks Fabric OS 6.2.x administrator guide for backup information. - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 177
will require that existing Telnet sessions be restarted. To reboot a single logical switch on this system, use the switchreboot command while logged in to that logical switch. Are you sure you want the CP blades during the replacement. HP StorageWorks DC and DC04 SAN Backbone Director Switches 177 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 178
backing up the configuration files: swDir:admin> configUpload Protocol (scp or ftp) [ftp]: ftp Server Name You can use a serial cable or Telnet, Web Tools, or Fabric Manger. Determine which CP is active synchronized and the failover is complete. 4. Power off the blade by sliding the slider switch - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 179
of the CP blade inside the left and right blade guides in the slot. Slide the CP blade into the slot power LED is green. If it is not, ensure that the CP blade has power and is firmly seated and that the ejectors are in the locked position. 6. Connect the cables to the new CP blade. HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 180
Heartbeat Up and HA-state in sync. If HA is not enabled, POST is not complete or the CP blades have not achieved redundancy, wait one or two minutes and re-enter the command until you can verify that redundancy has been achieved. 4. Type slotShow. The command output shows the new - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 181
truncated> tz mtracer-tool lkcd sysstat Removing been updated. 13. Pack the faulty CP blade in the packaging provided with the new CP blade, and contact HP for the procedure for : one in slot 3 and one in slot 6. HP StorageWorks DC and DC04 SAN Backbone Director Switches 181 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 182
faulty: • The status LED on the core switch blade is lit amber, or the power LED is not lit. • The slotShow command does not show that the core switch messages • Generic system driver messages (FABSYS) • Platform system driver messages (Platform) • EM messages that indicate a problem with a core - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 183
grounding connections above the power connectors on the chassis and right blade guides in the slot, Pack the faulty core switch blade in the packaging provided with the new core switch blade, and contact the DC04 SAN Director supplier for the procedure for returning the faulty blade. HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 184
requires a minimum of one power supply slot at all times to ensure power to the DC04 SAN Director. 2. Turn off the power switch. 3. Remove the power cord. 4. Loosen the thumb screw. 5. Grasp the handle and pull, sliding the power supply from the chassis and supporting the power supply from beneath - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 185
4. Replace the power cord. 5. Turn on the power switch. 6. Verify that the power LED on the power supply displays a steady green light. Figure 70 Power supply Replacing a : • Replacement blower assembly • Phillips #2 screwdriver HP StorageWorks DC and DC04 SAN Backbone Director Switches 185 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 186
Grasp the handle and pull, sliding the blower assembly from the chassis and supporting the blower assembly from beneath as you remove it (see Figure 71). , pushing firmly to ensure that it is seated. 2. Verify that the power LED displays a green light. 3. Use the screwdriver or your fingers to - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 187
(such as HyperTerminal for Windows systems or TIP for Solaris systems) How to determine whether or not Problems viewing or modifying the data stored on the WWN card, see Table 37 • Error messages regarding WWN units #1 or #2, see Table 38 To determine the status of a WWN card: HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 188
off) Card is faulty. Card is okay. No action required Check card. No action required NOTE: If a status LED on the WWN bezel flashes, the power LED on the WWN bezel also flashes, for increased visibility. 2. Check the WWN card status using the commands listed in Table 37. Difficulty retrieving or - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 189
power on , [EM-1049], ,, INFO, , FRU WWN # insertion detected. , [EM-1004], ,, CRITICAL, , WWN # failed to power [y/n]? to be displayed, and then type y. HP StorageWorks DC and DC04 SAN Backbone Director Switches 189 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 190
process to be completed. If this process is not complete due to a power cycle, or CP failover, please follow the recovery procedure in Core Switch WWN Backing up WWN card data, please wait about 25 seconds for further instruction. Please install the new FRU now. If this session lost for any reason, - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 191
: Wear a grounded ESD strap when handling the WWN card. Use the grounding connections above the power connectors on the chassis. 1. Unpack the new WWN card and save the packaging for the faulty on the console because of the replacement. HP StorageWorks DC and DC04 SAN Backbone Director Switches 191 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 192
tighten the two screws. 6. Pack the faulty WWN card in Gb/s. The 4-Gb/s SFPs autonegotiate at 1-, 2-, and 4-Gb/s. To remove an SFP or XFP (FC10-6 blade only) transceiver, pull the bale down and out, sliding the transceiver out of the port or application blade. To install an SFP or XFP, position one - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 193
SFP and XFP) extraction tool Replacing the DC04 SAN must be removed from the fabric and powered off to perform this procedure. Contact HP if you have any questions about whether for Windows systems or TIP for Solaris systems), required only if serial console session used HP StorageWorks DC and DC04 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 194
troubleshoot the chassis, following the list below, and contact your support guides that prevents correct installation of a blade. • Bent or damaged connectors on the backplane (the surface inside the chassis to which the blades connect). • One or more components (such as a power Reference Manual. Use - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 195
Reference. rsl8-st03-dcx-1:admin> configupload Protocol (scp or ftp) [ftp]: ftp Server Name or IP Address [host]: 123.123.123.123 User Name [user]: Admin24 File Name [config.txt]: config-switch0.txt Password: Upload complete rsl8-st03-dcx-1:admin> HP StorageWorks DC and DC04 SAN Backbone Director - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 196
listed is the same as the chassis serial number. rsl8-st03-dcx-1:admin> chassisshow Chassis Backplane Revision: 1F SW BLADE Slot: 1 Header Version: Power Consume Factor: Factory Part Num: Factory Serial Num: Manufacture: Update: Time Alive: Time Awake: 2 -50 60-0001532-03 KP000000195 Day: 1 Month - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 197
CHASSIS/WWN Unit: 1 Header Version: Power Consume Factor: Factory Part Num: Factory Serial Num: Manufacture: Update: Time Alive: Time Awake: (in same Name Enet IP Addr FC IP Addr Name rsl8-st03-dcx-1:admin> HP StorageWorks DC and DC04 SAN Backbone Director Switches 197 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 198
longer depending on the size of the SAN. This file provides a backup of all the information that might be required by Technical Support. The information can sysshutdown This command will shutdown the operating systems on your switch. You are required to power-cycle the switch in order to restore - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 199
chassis provides a grounding connection above the power connectors. Also, store ESD-sensitive components packing materials for use when returning the old chassis. d. If the chassis must be transported to the installation location, leave the chassis on top of the plastic shipping tray HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 200
correct level. If installing the chassis in a cabinet, follow the instructions provided by the rack kit manufacturer. Installing components into the new chassis . 12. Verify that the DC04 SAN Director is powered on and POST is complete (all power LED indicators on the port, control processor, and - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 201
rsl8-st03-dcx-1:root> 3. Verify that the chassis serial number has been entered correctly by typing chassisShow at the prompt. Verifying that the system is operating correctly To verify that the DC04 SAN Director is operating correctly: HP StorageWorks DC and DC04 SAN Backbone Director Switches 201 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 202
1. Log in to the DC04 SAN Director as admin: rsl8-st03-dcx-1:admin> login login: admin password: xxxxxxxx rsl8-st03-dcx-1:admin> 2. Type slotShow command and verify that all the installed cards are detected and that their status is operational (enabled). rsl8-st03-dcx-1:admin> slotShow Slot Blade - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 203
Ethernet port. b. Connect the other ends to an Ethernet 10/100 Base-T LAN, if not already connected. IMPORTANT: The DC04 SAN Director can tools, such as Telnet or Web Tools. Ensure that the DC04 SAN Director is not modified using other connections during the rest of this procedure. HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 204
ports and cables used in trunking groups must meet specific requirements. For a list of these requirements, refer to the HP StorageWorks Fabric OS 6.2.x administrator guide. a. Position one of the transceivers so that the key is oriented correctly to the port and insert the transceiver into the port - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 205
created earlier. In particular, look for differences in the following: • Device types • Number of devices • ISL and port states • Number of switches in the fabric HP StorageWorks DC and DC04 SAN Backbone Director Switches 205 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 206
SAN Director or fabric. • If there are any mechanical problems, try reseating the associated component. • If the configuration information : xxxxxxxx download complete rsl8-st03-dcx-1:admin> • If other issues exist, contact HP. Cable routing table Table 40 is a 48-port template for a cable-routing - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 207
Slot/port Slot Cable labels Port 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Switch end Device end Connected device Slot/port of device HP StorageWorks DC and DC04 SAN Backbone Director Switches 207 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 208
Slot/port Slot Cable labels Port 41 42 43 44 45 46 47 48 Switch end Device end Connected device Slot/port of device 208 Replacing DC04 SAN Director field-replaceable units (FRUs) - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 209
with FC-SW 5.0 Complies with FC-IP 2.3 of the FCA profile DC SAN Director: 6144 Gb/s, end-to-end DC04 SAN Director: 3 Tbps per chassis Port to port latency Less than 2 microseconds with no contention (destination port is free) HP StorageWorks DC and DC04 SAN Backbone Director Switches 209 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 210
frames in a 64-port switch) System architecture Table 42 DC SAN Director system architecture Fibre Channel Ports Control Processor Gb/s, cut-through routing. For the FR4-18i blade: - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 211
is based on switch type (U_Port) with an optional port type control. Data traffic types Media types Fabric switches supporting unicast, Service, NTP, Syslog, RASlog, auditing Inter-chassis linking (ICL) Chassis-to-chassis linkage through connectors on the core switch blade (CR8) HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 212
µsec any port to any port at 4 Gb/s, cut-through routing. Maximum frame size Frame buffers Classes of service Port types 2112-byte payload 2048 per ASIC, dynamically allocated Class 2, Class 3, Class F (interswitch frames) The FC8-16 and FC8-32 supports these port types: FL_Port, F_Port, E_Port - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 213
Domains, Reliable Commit Service, NTP, Syslog, RASlog, auditing Inter-chassis linking (ICL) Chassis-to-chassis linkage through connectors on the core switch blade (CR4S-8) System size and weight The 20 cm (28.82 in.) 68 kg (150 lb.) HP StorageWorks DC and DC04 SAN Backbone Director Switches 213 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 214
chassis: • No blades • No CP blade • No core switch blade • No power supplies • No fan assemblies Size and weight 25.76 kg (56.8 lb.) System blade and FRU weights Table 46 System FRU weights FRU CP blade (CP8) CR blade (CR8, CR4S-8) FC8-16 port blade FC8-32 port blade FC8-48 port blade - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 215
Maximum output power: 1000 watts 40A maximum power subsystem is a redundant +48V DC power distribution system with a provision for up to two 2000-watt, 48V DC bulk power supplies. Two bulk power supplies produce the intermediate distribution voltage in the distributed power system. HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 216
line (180 - 264 VAC), 2000W 20A maximum, peak AC power consumption is configuration-specific. A system with four FC8-48 port blades (loaded with 1W SFPs), power receptacles on each chassis are equipped with IEC 60320/C20 power connectors. Contact HP to order a power cord. CAUTION: Never use the power - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 217
Czech, Rep. of X Denmark X Egypt X England X Finland X X France X Germany X Greece X Hong Kong X Hungary X India X Indonesia X Ireland, North X Ireland, South X Israel X Italy X Japan X Korea, South X HP StorageWorks DC and DC04 SAN Backbone Director Switches 217 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 218
Country Plug style NEMA L6-20 USA, Canada, Mexico, other North American locations CEE-7/7 "Schuko" Continental Europe/Ireland BS-1363A United Kingdom/ Hong Kong AS 3112 Australia/New Zealand IEC-60309 32A-6h, 230 V~ Malaysia Alternate Mexico X Monaco X Netherlands New Zealand Norway - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 219
IEC-60309 32A-6h, 230 V~ Venezuela X Yugoslavia X Power cords (Japan, Denan) Environmental requirements Table 50 lists the are also provided for acceptable storage and transportation environments. Table duration, half-sine wave HP StorageWorks DC and DC04 SAN Backbone Director Switches 219 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 220
LEDs, error messages, and Fabric Watch alerts will indicate a problem. Use the tempShow command or Fabric Watch commands to view temperature Director and DC04 SAN Director support full duplex link speeds at 10.51875, 8.50, 4.25, 2.125, or 1.0625 Gb/s inbound and outbound, automatically negotiating - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 221
), or E_Ports (expansion ports). The ports meet all required safety standards. For a listing of these standards, see "Regulatory compliance and safety notices" on page 229. HP StorageWorks DC and DC04 SAN Backbone Director Switches 221 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 222
and port speeds. Table 52 Supported cable speeds and distances Cable type Speed Single Mode 9 microns 2 Gb/s 4 Gb/s 8 Gb/s Multi Mode 50 microns 2 Gb/s 4 Gb/s 8 Gb/s 62.5 microns 2 Gb/s 4 Gb/s 8 Gb/s Minimum distance 2 m 2 m 2 m 0.5 m 0.5 m 0.5 m 0.5 m 0.5 m 0.5 m Maximum distance 10 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 223
(GbE) SFP ports supporting the Fibre Channel Over IP (FCIP) feature. It operates with the Fabric Operating System and can communicate with another FR4-18i or an HP 400 Multi-protocol (MP) Router for both Fibre Channel Routing services and FCIP, or an HP Multi-protocol (MP) Router for Fibre Channel - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 224
into the Director" on page 224 2. "Configuring FCIP and Fibre Channel Routing Services and enable the ports" on page 226 3. "Cabling the FR4-18i blade with the firmware version on the active CP. 5. Verify that the blade power and blade status LEDs are green after the blade has completed booting. NOTE - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 225
Router blade (FR4-18i) components 25198a 1. Blade power LED 3. FC port 5. Thumb screw 7. ON/OFF slider switch 9. GbE ports (2) 11. Lower ejector 13. GbE port status LED 2. Blade status LED 4. Upper ejector. 6. FC port status LED 8. FC port 10. Thumb screw 12. FC port status LED HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 226
the Fibre Channel Routing Services feature prior to enabling the ports. The GbE ports can only be used once you have configured FCIP and enabled the VE_Ports. See the HP StorageWorks Fabric OS 6.2.x administrator guide for detailed instructions on configuring the Fibre Channel Router ports and GbE - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 227
management before installing the blade. • Leave at least one meter of slack for each port cable. This provides room to remove and replace the blades, and helps prevent the cables from being bent to less than the minimum bend radius. HP StorageWorks DC and DC04 SAN Backbone Director Switches 227 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 228
228 Intelligent blades - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 229
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a the marketing name or model number of the product. HP StorageWorks DC and DC04 SAN Backbone Director Switches 229 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 230
Laser device All HP systems equipped with a laser device comply with safety standards, including to the laser device other than those specified herein. • Allow only HP authorized service technicians to repair the laser device. Certification and classification information This product contains - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 231
optional label in Figure 75 or equivalent may be located on the surface of the HP supplied laser device. This label indicates that the product is classified as a CLASS GmbH, HQ-TRE, Herrenberger Strasse 140, 71034 Boeblingen, Germany HP StorageWorks DC and DC04 SAN Backbone Director Switches 231 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 232
Japanese notice Korean notices Korean Notice 232 Regulatory compliance and safety notices - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 233
compliance requirements for the HP StorageWorks DC SAN Backbone Director Switch and the HP StorageWorks DC04 SAN Backbone Director Switch will be used under normal conditions in accordance with the operating manual of the product. EPUP EPUP FRU Brocade Brocade CD Br ocade - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 234
and Slides X O O O O O Slot Filler X O O O O O Cable management comb X O O O O O Cable Comb O O O O O O Cables and power cords O O O O O O Replacement Doors X O O O O O Software/ Documentation CDs O O O O O O X indicates that the concentration of such - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 235
. Electrostatic discharge recommendations To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may HP StorageWorks DC and DC04 SAN Backbone Director Switches 235 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 236
system methods for grounding. Use one or more of the following field service tools. • Use a portable field service kit with HP authorized reseller or HP authorized service provider. WARNING! Your switch contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 237
authorized service provider. NOTE: Route power cords so that they will not be walked on and cannot be pinched by items placed upon or against them. Pay particular attention to the plug, electrical outlet, and the point where the cords exit from the product. Japanese power cord notice HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 238
238 Regulatory compliance and safety notices - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 239
the port numbering pattern for the DC SAN Director or DC04 SAN Director. HP StorageWorks DC SAN Backbone Director Switch templates The following port templates are provided for the blades • FC10-6 port blade • FR4-18i router blade HP StorageWorks DC and DC04 SAN Backbone Director Switches 239 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 240
Figure 76 Port side populated with eight FC8-48 port blades, two CR8 blades, and two CP8 blades 240 Port numbering templates - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 241
26389a Figure 77 Port side populated with eight FC8-32 port blades, two CR8 blades, and two CP8 blades HP StorageWorks DC and DC04 SAN Backbone Director Switches 241 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 242
26388a Figure 78 Port side populated with eight FC8-16 port blades, two CR8 blades, and two CP8 blades 242 Port numbering templates - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 243
Figure 79 FC10-6 port blades HP StorageWorks DC and DC04 SAN Backbone Director Switches 243 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 244
Figure 80 FR4-18i router blade 244 Port numbering templates - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 245
, two CR4S-8 blades, and two CP8 blades • FC10-6 port blade • FR4-18i router blade The individual blades are shown vertically to make it easier to read the port numbering. Their orientation in the DC04 SAN Director chassis is horizontal. HP StorageWorks DC and DC04 SAN Backbone Director Switches 245 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 246
Figure 82 Port side populated with four FC8-48 port blades, two CR4S-8 blades, and two CP8 blades 246 Port numbering templates - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 247
Figure 83 Port side populated with four FC8-32 port blades, two CR4S-8 blades, and two CP8 blades HP StorageWorks DC and DC04 SAN Backbone Director Switches 247 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 248
Figure 84 Port side populated with four FC8-16 port blades, two CR4S-8 blades, and two CP8 blades 248 Port numbering templates - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 249
Figure 85 FC10-6 port blades HP StorageWorks DC and DC04 SAN Backbone Director Switches 249 - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 250
Figure 86 FR4-18i router blades 250 Port numbering templates - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 251
23 blades, DC04 available for, 118 blades, DC support for, 19 blades, DC04 support for, 113 blower assembly, DC status, 69 blower power cord, 237 core switch blade, DC04 See CR blade, DC04, 113 core switch blade, DC See CR blade, DC, 19 CP blade, DC replacing, 79 status, 64 HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 252
, 147 network manageability features, 121 power requirement, 215 powering on, 138 reliability features, 119 security features, 121 serviceability features, 120 site preparation, 126 size and weight, 213 software features, 120 specifications, 209 system architecture, 212 unpacking, 126 directive - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 253
port specifications, 220 Routing Services, 223 field-replaceable units, power supply, 164 power supply LEDs, 165 replacing, 184 WWN bezel replacing, 187 WWN card replacing, 187 H hardware components, DC, 20 hardware components, DC04, 114 hardware kits, DC, 27 hardware kits, DC04, 123 HP StorageWorks - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 254
help obtaining, 17 HP series number, 229 technical support, 17 I ICL kit, DC, 43 ICL kit, DC04, 140 IEC blade, DC, 66 CP blade, DC04, 161 CR blade, DC, 68 CR blade, DC04, 164 power supply, DC, 69 power supply, DC04, 165 licenses, software, DC, 26 licenses, software, DC04, 122 lithium battery, 236 M - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 255
, 149 symbols in text, 16 system architecture, DC SAN Director, 210 system architecture, DC04 SAN Director, 212 T Taiwan EPA battery recycling and disposal, 237 tasks, installation, DC, 29 tasks, installation, DC04, 125 technical support HP, 17 technical support service locator website, 18 template - HP StorageWorks 4/64 | HP StorageWorks DC and DC04 SAN Backbone Director Switche - Page 256
256
HP StorageWorks DC and DC04 SAN
Backbone Director Switches
hardware reference guide
Part number: 5697–7814
Second edition: February 2009