HP StorageWorks 8/80 HP StorageWorks 8GB SAN Switch hardware reference guide ( - Page 41
This also applies to the Encryption SAN Switch, FCoE Converged Network Switch,
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 41 highlights
7. Secure the two inner rails (one on each side) to the device, using the appropriate number of screws (see Table 6). For example, Figure 19 shows an inner rail attached to the MP Router with three screws, using the two rail screw holes marked R and one marked 16. Attaching both rails requires six screws. This figure also applies to the Encryption SAN Switch, FCoE Converged Network Switch, and 1606 Extension SAN Switch. Figure 20 shows an inner rail attached to the 4/64 SAN Switch with five screws, using the rail screw holes marked 16. Attaching both rails requires ten screws. This figure also applies to the 8/8, 8/24, 8/40, and 8/80 SAN Switches. Figure 19 Securing the inner rails to an MP Router . Figure 20 Securing the inner rails to the 4/64 SAN Switch . NOTE: For factory integration only, tighten the #8-32 x 5/16-inch Phillips panhead SEMS screws and torque between 6 and 8 inch-pounds. 8-Gb SAN Switch Hardware Reference Guide 41