HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.1.0g release notes (5697-7861 - Page 26
Fabric OS 6.1.0f, Fabric OS 6.1.0g
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
Fabric OS 6.1.0f fixes Table 12 lists defects closed in this Fabric OS 6.1.0f firmware release. Table 12 Fabric OS 6.1.0f closed defects Closed defect summary Solution A failed Pause frame, sent during firmwaredownload process in Interop Modes 2 and 3, causes a fabric rebuild Fixed in Fabric OS 6.1.0f. Workaround: Use the firmwaredownload -o option to override the uncooperative HCL feature. A device with a slow initialization sequence may cause the switch to mistakenly establish virtual channels on an F_Port. Fixed in Fabric OS 6.1.0f. A CRC error was observed between HP StorageWorks 8/40 SAN Switch and HP StorageWorks 8/80 SAN Switch with a particular SFP type. Fixed in Fabric OS 6.1.0f. The Fibre Channel fastwrite path does not recover after restoring the DWDM connection. Fixed in Fabric OS 6.1.0f. Devices on the backbone have no access to remote devices after a switch on the backbone, with both FCR and FCIP being utilized, experiences a hafailover or hareboot. Fixed in Fabric OS 6.1.0f. Workaround: To recover, disable and then enable the VEX/EX ports. Port RSCNs are sent to DPC (VIs and VTs) every time the configuration changes, which is unrelated to VI/VT. This affects any application Fixed in Fabric OS 6.1.0f. that uses frame redirect zoning. With both RD zone and TI zone configured, a connectivity issue can occur after hafailover or hareboot. Fixed in Fabric OS 6.1.0f. Workaround: Run the efgdisable and efgenable commands. Fabric OS 6.1.0g fixes Table 13 lists defects closed in the Fabric OS 6.1.0g firmware release. Table 13 Fabric OS 6.1.0g closed defects Closed defect summary Solution During firmwaredownload, a rare race condition could occur, causing /etc/inetd.conf to be erased, and leading to the user being unable to access the switch via the network. Fixed in Fabric OS 6.1.0g. A Web Tools performance issue occurs, where it freezes for a few seconds approximately every 15 seconds. The Web Tools light stops blinking and cannot scroll any windows. Fixed in Fabric OS 6.1.0g. With FC fastwrite zones (connecting local hosts to remote devices) and non-FC fastwrite zones (connecting local hosts to local devices) going to the same devices, not all host ports receive RSCNs after device logon and link down. Fixed in Fabric OS 6.1.0g. Workaround: Run portdisable and portenable on the initiator port to regain host and device connection. When first upgrading a newly-installed Fabric OS 6.0.x Director to Fabric OS 6.1.x, there is a very small window of time in which 8-Gb blades may fault. Fixed in Fabric OS 6.1.0g. With Fabric OS 6.1.x, an undefined bit is sometimes set in the RSCN payload that causes spurious fabric logout and login issues for HBA Fixed in Fabric OS 6.1.0g. Fibre Channel drivers. 26