HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.2.0b release notes (5697-0352 - Page 25

Web Tools functionality Moved to DCFM, Gb SAN Switch for HP, BladeSystem c-Class

Page 25 highlights

Table 6 portcfgfillword command summary Fabric OS version All 8-Gb switches (except 8-Gb 8-Gb SAN Switch for HP SAN Switch for HP BladeSystem BladeSystem c-Class c-Class) All ports set to idles. No arb(ff) Any Fabric OS earlier than 6.1.2 capability existed. 1 All ports set to idles. No arb(ff) capability existed. 2 FOS 6.2.0x prior to 6.2.0c Arb(ff) by default on all ports and can't be changed. All ports default to arb(ff) (internal and external) and can't be changed. 6.1.2x and 6.2.0c and later (HP Added the ability to change portcfg- Added the ability to change portcfg- did not support 6.2.0c) fillword to idle or arb(ff). 1 fillword to idle or arb(ff). 2 6.1.2x and 6.2.0d through 6.2.x All ports default to idle [mode 0] regardless of what FOS was previously installed, unless manually changed to arb(ff) previously [mode 1], then it will remain arb(ff). Can be changed by the user. • If 6.2.0d was installed in the factory, all internal ports remain at arb(ff) [mode 1], external ports at idle [mode 0]. Can be changed by the user. • If pre-6.2.0d was installed in the factory, all internal and external ports remain at idle [mode 0], unless they were manually changed to arb(ff) [mode 1], then they remain at arb(ff). Can be changed by the user. Mode: 0-IDLE for Link Init, IDLE for fill word 1-ARB(FF) for Link Init, ARB(FF) for fill word (NOTE: not supported with XP storage arrays) 16.1.2x was not supported on EVA4400 embedded switch module. 26.1.2x was not supported on this switch. Web Tools functionality Moved to DCFM The functionality that was moved from Web tools in 6.1.1 to DCFM is applicable to both DCFM Professional and DCFM Enterprise and is also applicable to 6.2.x. Table 7 specifies these changes. Table 7 Web Tools functionality in DCFM Function Web Tools 6.1.0 DCFM Comments Add unzoned devices Zone Admin Configure > Zoning Reverse Find in the zoning dialog provides the view of the zoned and unzoned devices in the fabric is all zone members are selected for Find. HP StorageWorks Fabric OS 6.2.0b release notes 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

Table 6 portcfgfillword command summary
8-Gb SAN Switch for HP
BladeSystem c-Class
All 8-Gb switches (except 8-Gb
SAN Switch for HP BladeSystem
c-Class)
Fabric OS version
All ports set to idles. No arb(ff)
capability existed.
2
All ports set to idles. No arb(ff)
capability existed.
1
Any Fabric OS earlier than 6.1.2
All ports default to arb(ff) (internal
and external) and can
t be
changed.
Arb(ff) by default on all ports and
can
t be changed.
FOS 6.2.0x prior to 6.2.0c
Added the ability to change portcfg-
fillword to idle or arb(ff).
2
Added the ability to change portcfg-
fillword to idle or arb(ff).
1
6.1.2x and 6.2.0c and later (HP
did not support 6.2.0c)
If 6.2.0d was installed in the
factory, all internal ports remain
at arb(ff) [mode 1], external
ports at idle [mode 0]. Can be
changed by the user.
If pre-6.2.0d was installed in the
factory, all internal and external
ports remain at idle [mode 0],
unless they were manually
changed to arb(ff) [mode 1],
then they remain at arb(ff). Can
be changed by the user.
All ports default to idle [mode 0]
regardless of what FOS was previ-
ously installed, unless manually
changed to arb(ff) previously [mode
1], then it will remain arb(ff). Can
be changed by the user.
6.1.2x and 6.2.0d through 6.2.x
0
IDLE for Link Init, IDLE for fill
word
1
ARB(FF) for Link Init, ARB(FF) for
fill word (NOTE: not supported with
XP storage arrays)
Mode:
1
6.1.2x was not supported on EVA4400 embedded switch module.
2
6.1.2x was not supported on this switch.
Web Tools functionality Moved to DCFM
The functionality that was moved from Web tools in 6.1.1 to DCFM is applicable to both DCFM
Professional and DCFM Enterprise and is also applicable to 6.2.x.
Table 7
specifies these changes.
Table 7 Web Tools functionality in DCFM
Comments
DCFM
Web Tools 6.1.0
Function
Configure > Zoning
Reverse Find in the zoning dialog
provides the view of the zoned
and unzoned devices in the fabric
is all zone members are selected
for Find.
Zone Admin
Add unzoned devices
HP StorageWorks Fabric OS 6.2.0b release notes
25