specific port speed for N_Ports also decreases fabric build time. However, setting a specific port speed for N_Ports is not required. There are a few older HBA devices that do not always succeed in logging in to a switch port when the port speed is set for auto-negotiate. Workaround If an older HBA has difficulty logging into a switch port that has its port speed configured as Negotiate, configure that port speed to 1Gb/sec, 2Gb/sec, or 4Gb/sec according to the operating speed of the HBA connected to that port. Known issues in firmware 09.06.02 Table 7 lists the known issues in firmware 09.06.02. Table 7 Firmware 09.06.02 known issues Issue Workaround For Edge Switches, the alias database persists after The alias database can be successfully cleared through a configuration reset, where it should be cleared. the CLI and EFCM basic. In a FICON environment, PDCM is reset to default following activating Open Trunking. Save the PDCM configuration before activating Open Trunking, and activate the saved PDCM after activating Open Trunking. QPM installed in a director, a cable move followed by a port speed change under specific conditions may cause an erroneous entry in the nameserver for a disabled port. The sequence of events that could cause this are: 1) a QPM is configured with all port speeds set to burst mode 2) there are active links on an odd number port (1 or 3) and on the even number port that is not its corresponding sustain mode port (2 or 0, respectively). 3) the link to the odd numbered port (1 or 3) is moved to its corresponding sustain mode port (0 or 2, respectively) 4) the port speed for the other even numbered port is changed to sustained mode 5) the entry for the odd number port that was moved (disconnected) may re-appear in the nameserver If this is issue is encountered, configure both the even ports of the QPM card to sustained mode instead of configuring only one. In a FICON environment, if a connected device has zero Buffer-Buffer (BB) credits, a PLOGI to that device from other devices may fail unless the BB credits recover. Blocking and unblocking the switch port of the device will allow the PLOGI to succeed. Determining current version This section describes how to determine the current version of firmware for an Edge Switch or Director using the HAFM, HAFM Basic, or the CLI. Using HAFM To determine the current version using HAFM: 1. Open the Element Manager for the Edge Switch or Director. 2. Select Product > Properties from the menu bar. The firmware version appears in the dialog box. Director and Edge Switch release notes 15