HP Surestore 64 HP StorageWorks Director and Edge Switch Release Notes - FW09. - Page 6

Table 3 Fixes in, rmware version 09.03.00

Page 6 highlights

Description Affected models Management server FICON fault not sending field replaceable unit (FRU) change notification to EFCM. Director 2/140, 2/64 Known bad SFP reported incorrectly in Equip Check if plugged into QPM. Director 2/140, 2/64 F-port did not always login after power on. M4400 SNMP reported duplicate traps on port card insertion. Director 2/140, 2/64 Multicast packets were erroneously sent to Ethernet switch. Director 2/140 CTP processor fault event 411 sometimes occurred after CTP reset. Director 2/140 In a FICON environment, when a QPM was swapped for an XPM, or an XPM was swapped for a QPM, the prohibit dynamic connectivity masks (PDCM) of the affected ports were not cleared, and PDCMs could be configured via HAFM. Director 2/64 Attempts to activate a large zone set through OSMS when common transport (CT) authentication was enabled All occasionally was not be successful. Table 3 Fixes in firmware version 09.03.00 Description Affected models False optics mismatch error was sometimes reported when firmware was upgraded to 09.00.00 or 09.02.00 Director 2/64, ES-3032 If a device sent an OSMS Get Attached Port_Name List (GAPNL) request to a port name that did not exist in the fabric, the information unit (IU) buffer did not release, and after repeated requests would eventually deplete the IU memory. When the IU buffer pool was depleted, the fabric could segment. This was specific to this OSMS command and would occur only if the target device did not exist or did not respond to the command. Director 2/140 Vital Product Data (VPD) containing the CTP serial number and CTP part number was being deleted after inserting a spare. This information is for electronic viewing purposes only and did not impact operation of the CTP. Director 2/140, Director 2/64 IP ping over FC was not working. Sphereon 4700 Hitachi Data Systems (HDS) AMS1000 storage had problems logging in intermittently. Director 2/64 SNMP get IP command failed on Sphereon 4400 and Edge Switch 2/24, Director 2/140, Sphereon returns 127.0.0.1. 4400, 4700 Storage devices needed to register as FC-4 type in order to boot across an Edge Switch 2/24. Edge Switch 2/24 IML/IPL was required to increment the Power-on hours for the command line interface (CLI) command SHOW FRU. Director 2/64 Event 421, Informational Event, did not correctly identify the firmware version for Sphereon 4400, 4700. Sphereon 4400, 4700 HAFM was unable to manage switches after firmware upgrade due to the gateway address to the switch IP address changing. Edge Switch 2/24 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

Description
Affected models
Management server FICON fault not sending
eld
replaceable unit (FRU) change noti
cation to EFCM.
Director 2/140, 2/64
Known bad SFP reported incorrectly in Equip Check if
plugged into QPM.
Director 2/140, 2/64
F-port did not always login after power on.
M4400
SNMP reported duplicate traps on port card insertion.
Director 2/140, 2/64
Multicast packets were erroneously sent to Ethernet
switch.
Director 2/140
CTP processor fault event 411 sometimes occurred after
CTP reset.
Director 2/140
In a FICON environment, when a QPM was swapped
for an XPM, or an XPM was swapped for a QPM, the
prohibit dynamic connectivity masks (PDCM) of the
affected ports were not cleared, and PDCMs could be
con
gured via HAFM.
Director 2/64
Attempts to activate a large zone set through OSMS
when common transport (CT) authentication was enabled
occasionally was not be successful.
All
Table 3 Fixes in
rmware version 09.03.00
Description
Affected models
False optics mismatch error was sometimes reported
when
rmware was upgraded to 09.00.00 or 09.02.00
Director 2/64, ES-3032
If a device sent an OSMS Get Attached Port_Name List
(GAPNL) request to a port name that did not exist in the
fabric, the information unit (IU) buffer did not release,
and after repeated requests would eventually deplete the
IU memory. When the IU buffer pool was depleted, the
fabric could segment. This was speci
c to this OSMS
command and would occur only if the target device did
not exist or did not respond to the command.
Director 2/140
Vital Product Data (VPD) containing the CTP serial
number and CTP part number was being deleted after
inserting a spare. This information is for electronic
viewing purposes only and did not impact operation of
the CTP.
Director 2/140, Director 2/64
IP ping over FC was not working.
Sphereon 4700
Hitachi Data Systems (HDS) AMS1000 storage had
problems logging in intermittently.
Director 2/64
SNMP
get IP
command failed on Sphereon 4400 and
returns
127.0.0.1
.
Edge Switch 2/24, Director 2/140, Sphereon
4400, 4700
Storage devices needed to register as FC-4 type in order
to boot across an Edge Switch 2/24.
Edge Switch 2/24
IML/IPL was required to increment the Power-on hours for
the command line interface (CLI) command
SHOW FRU
.
Director 2/64
Event 421, Informational Event, did not correctly identify
the
rmware version for Sphereon 4400, 4700.
Sphereon 4400, 4700
HAFM was unable to manage switches after
rmware
upgrade due to the gateway address to the switch IP
address changing.
Edge Switch 2/24
6