Honeywell 6149EX Installation Guide - Page 2
‡K6205EXV3uŠ - keypad
View all Honeywell 6149EX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
7. Test the tamper function and adjust the plunger (if necessary) before securing the keypad to its case back with the screw (refer to Figure 3). 8. Install the cover or the optional door substitute trim, if the cover will not be used. OR ARMED A BC 1 OFF 4 MAXIMUM 7 2 AWAY 5 TEST 3 STAY 6 INSTANT 8 CODE BYPASS 9 0 READY CHIME READY D 6165EX-004-V1 Figure 3 - Securing the Case (shown with cover removed) PROGRAMMING THE KEYPAD Setting the Keypad Address The keypad can either be set for an address of 00-30, or to the non-addressable mode (31). The keypad's default address is 31. To change the keypad's address, perform the following steps: 1. Enter address mode: Power up the keypad. Within 60 seconds of power-up, press and hold down the [1] and [3] keys at the same time for 3 seconds. (If unable to enter address mode, power down and try again.) The current keypad address will be displayed, and the tens" digit will blink. If 10 seconds have passed with no key entry, the keypad automatically exits address mode. You must power down, power up and start address mode again. NOTE: The keypad will not enter address mode if the panel to which it is connected is in programming mode. 2. Set the current address to "00": Press [0] to clear the current "tens" digit. The "ones" digit will blink. Press [0] to clear the current "ones" digit. The "tens" digit will blink. 3. Enter the keypad's address: Enter the proper "tens" digit of the keypad's address. The "ones" digit will blink. Enter the proper "ones" digit of the keypad's address. Note that address "31" sets the keypad to non-addressable mode. 4. Exit address mode: Press [✻] to exit address mode and proceed to display mode. Setting the Display Mode The 6149EX/6165EX has three optional display modes. The default option "d1" will be displayed on the keypad. Option 1: The display is always active. Option 2: The display and LEDs are blanked until a key is pressed. The display will remain active for 45 seconds after the last key has been pressed. Option 3: The display and LEDs are blanked 45 seconds after the panel is armed and remains blank until the panel is disarmed 1. Select keypad option: Enter the option number. 2. Exit the display mode. Press [✻] to save the display settings and exit programming mode. VIEWING THE KEYPAD ADDRESS Press and hold down the [1] and [3] keys at the same time for about 3 seconds. The current address is displayed. No key entry is allowed. Press any key to exit or wait 10 seconds to exit viewing mode. SPECIFICATIONS Physical: Displays: 6149EX: 6165EX: Sounder: Voltage: Current: 6149EX: 6165EX: 4-7/8"H x 2-7/8"W x 1-1/4"D Fixed-Word LCD. 2 x 16 alpha-numeric supertwist LCD (backlit). Piezo-electric (fire alarm is loud, pulsing single tone; (all Keypads) burglary alarm is loud, continuous, dual tone). 12VDC 60mA (ARMED LED lit and sounder on), reduces to 40mA when panel is operating in standby mode. 70mA (ARMED LED lit, LCD backlight and sounder on), reduces to 40mA when panel is operating in standby mode (backlight off). REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM. To obtain applicable EU compliance Declaration of Conformities for this product, please refer to our Website http://www.security.honeywell.com/hsce/international/index.html Honeywell Security and Custom Electronics 2 Corporate Center Drive Melville, New York 11747 www.honeywell.com/security Honeywell Security and Custom Electronics Newhouse Industrial Estate, Motherwell Lanarkshire, ML1 5SB, Scotland, United Kingdom e-mail: [email protected] Telephone: +44 (0)1698 738200 Copyright © 2007 Honeywell International Inc. ‡K6205EXV3uŠ K6205EXV3 5/07 Rev. B