Page 13 highlights

SETUP Menu Functions Menu Item Description 1 LENS Selects Lens type. Options: DC = Automatic Iris lens. Press ENTER with DC selected to adjust the brightness level. MANUAL = Fixed lens 2 SHUTTER Adjusts shutter settings. Options: FLK = Flickerless mode reduces on-screen flickering. MANUAL = Adjusts the shutter speed from 1/601/100,000 of a second (NTSC), or 1/50-1/100,000 of a second (PAL). ESC = Electronic Shutter Control. Press ENTER to adjust the brightness level. Not available with DC lens. 3 WHITE BAL. Controls color on the screen. Press ENTER with (White ATW selected to change the mode. Options: Balance) ATW = Select Auto Tracking White Balance when the color temperature is 2500°K~8000°K (for example when under a fluorescent light, or outdoors). AWC PUSH = Automatically adjust the white balance to your specific environment. When selected, the white balance is locked. AWC AUTO = A faster AWB mode with a wider operating range. USER = Adjust the red or blue gain (0~255). MANUAL = Increase or decrease the red or blue gain on screen. 4 BACKLIGHT Control the light level to overcome severe backlighting conditions. 5 AGC (Automatic Gain Control) Adjusts value of AGC gain. Options: 18 dB~30 dB = Increase the gain level (in 2 dB increments) to brighten the picture in low light conditions. Noise/distortion may develop. OFF = DAY&NIGHT mode must be OFF to turn AGC OFF. 6 SPECIAL .. Opens the SPECIAL menu (see SPECIAL Menu). 7 EXIT MENU Exits the OSD; returns to video monitoring. Document 800-01954 Rev A 13 08/08

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Document 800-01954 Rev
A
13
08/08
SETUP Menu Functions
Menu Item
Description
1
LENS
Selects Lens type. Options:
DC
= Automatic Iris lens. Press
ENTER
with DC
selected to adjust the brightness level.
MANUAL
= Fixed lens
2
SHUTTER
Adjusts shutter settings. Options:
FLK
= Flickerless mode reduces on-screen
flickering.
MANUAL
= Adjusts the shutter speed from 1/60-
1/100,000 of a second (NTSC), or
1/50-1/100,000 of a second (PAL).
ESC
= Electronic Shutter Control. Press
ENTER
to adjust the brightness level. Not available with
DC lens.
3
WHITE BAL.
(White
Balance)
Controls color on the screen. Press
ENTER
with
ATW selected to change the mode. Options:
ATW
= Select Auto Tracking White Balance
when the color temperature is 2500°K~8000°K
(for example when under a fluorescent light, or
outdoors).
AWC PUSH
= Automatically adjust the white
balance to your specific environment. When
selected, the white balance is locked.
AWC AUTO
= A faster AWB mode with a wider
operating range.
USER
= Adjust the red or blue gain (
0~255
).
MANUAL
= Increase or decrease the red or blue
gain on screen.
4
BACKLIGHT
Control the light level to overcome severe
backlighting conditions.
5
AGC
(Automatic
Gain
Control)
Adjusts value of AGC gain. Options:
18 dB~30 dB
= Increase the gain level (in 2 dB
increments) to brighten the picture in low light
conditions. Noise/distortion may develop.
OFF
= DAY&NIGHT mode must be OFF to turn
AGC OFF.
6
SPECIAL ..
Opens the SPECIAL menu (see
SPECIAL Menu
).
7
EXIT MENU
Exits the OSD; returns to video monitoring.