Honeywell HTR4 Quick Start Guide

Honeywell HTR4 Manual

Honeywell HTR4 manual content summary:

  • Honeywell HTR4 | Quick Start Guide - Page 1
    and application support files, Honeywell recommends . See the HTR4 System Reference Guide for more information HTR4 Recorder. You must be logged into a Microsoft® Windows® 2000 (Service Pack 4), XP® (Professional and Home Edition Service set the time and date (manually or synchronized with your PC).
  • Honeywell HTR4 | Quick Start Guide - Page 2
    HTR4 Recorder is not already on (POWER LED is solid green when on), briefly press the POWER button on the front panel. Start the BusView Player application. Front Panel Indicators (LEDs) Recorder State Service @honeywell.com Document 800-00275 - Rev A - 03/08 © 2008 Honeywell International
  • 1
  • 2

HTR4 System Quick Setup
For more programming and operation, see over.
For more detailed information, refer to the
HTR4 System Reference Guide
available on your CD.
Document 800-00275 – 03/08 – Rev A
1
Unpack Everything
Make sure you have everything you need before you begin the installation:
2
Install the HTR4 Recorder
1.
Choose a location and mounting option that provides convenient access, is not subject to
high vibration or heat, and cannot be interfered with by unauthorized personnel.
2.
Attach the U-shaped bracket to the pre-drilled mounting surface using the sheet metal
screws. Secure the recorder to the bracket with the machine screws (hardware included).
3.
Connect the 24-pin Interface connector of the wiring harness to the recorder. Wire the
triggers and alarms to the vehicle electrical system. Connect the power cables to the
vehicle battery. Connect the GPS cabling to the HTR4GPS module, if installed.
4.
Install up to four cameras. The primary camera is typically installed at the front interior of the
vehicle looking towards the back. Other cameras might be installed on the ceiling halfway
down the aisle and on the bulkhead looking towards the driver and/or front door. For more
information, refer to the
Installation Guide
that came with your camera.
5.
Connect the camera(s) to the power, audio and video ports on the recorder’s rear panel.
6.
If you are not using the HTENCLHTR security enclosure, attach the optional front lid and
rear cable cover. Slide the front lid into its two slots at a 45° angle. Leave a 1/2 inch
clearance between the cable cover and the rear chassis.
7.
Install the BusView software on a PC or laptop that you will use to connect to the HTR4
Recorder. You must be logged into a Microsoft® Windows® 2000 (Service Pack 4), XP®
(Professional and Home Edition Service Pack 2), or Windows Vista (Home Premium and
Business editions) operating system with administrator privileges to install the software.
a.
Close all running Windows applications.
b.
Ensure that all other users are logged off.
c.
Remove any existing BusView applications.
d.
Insert the CD-ROM disc in the CD drive and then follow the Installation Wizard.
8.
With Windows running, connect your PC or laptop to the COMPUTER port on the front of
the recorder or on the dash panel unit (HTRDP) using a CAT5 Ethernet crossover cable.
HTR4 Recorder
1 to 4 mobile CCTV cameras
Recorder and camera cables
Administrator CD-ROM disc
Wiring harness
Mounting hardware
Optional installation kits (HTR4GPS, HTRDP, and so on)
Driver seat (between seat
and wall, or underneath)
Passenger seat
(underneath seat)
Bulkhead (on front
or underneath)
Glove box (inside
or underneath)
Possible Mounting Locations
Console
Middle of vehicle
(underneath seat)
*
*
*
*
*
*
Note
You can mount your recorder in any
orientation needed.
The U-shaped bracket can be inverted. It can
be used to mount the recorder suspended
underneath a flat surface or to mount it
supported on top of a flat surface.
TIP!
For more secure installations, we
recommend you install your recorder inside the
HTENCLHTR security enclosure. See the
HTENCLHTR Security Enclosure Installation
Guide
for more information.
Suspended
mount
OR
Supported
mount
Power harness: 20, 40
and 60 foot cables
Fuse box
(ATO 7.5)
NO1
NO2
NC1
NC2
COM1
COM2
TRIG1
TRIG2
TRIG3
TRIG4
TRIG5
TRIG6
For
future
use
Power
for GPS
To
vehicle
battery
Triggers
Alarms
Reserved for GPS
Power
Note
If you are installing the recorder into a
vehicle that previously ran an HTRD400 or
HTRD100 recorder, you can purchase a wiring
harness adapter that allows you to use your
currently wired triggers. See the
HTR4 System
Reference Guide
for more information.
VIDEO
IN
IN
AUDIO
CAMERA
POWER OUT
DC 12-14V
SPOT
MONITOR
REMOTE
PANEL
COM 2
COM 1
INTERFACE
1
2
3
4
1
2
3
4
24-pin Interface
connector
Rear Panel
Front Panel
Note
Only connect a PC or
laptop to the COMPUTER port
on the front panel
after
you
have installed the Configuration
software on the PC.
3
Program the System
Note
To ensure that you can read, write, and modify Configuration
data files and application support files, Honeywell
recommends that all users be administrator group members
of the Windows operating system.
First Time Mandatory Settings
1.
On a PC connected to the HTR4 Recorder, launch the BusView Configurator application. If
the recorder is not already awake (POWER LED is solid green when awake), press and hold
the POWER button on the front panel for 5 seconds.
2.
Click
Online Configuration
in the navigation pane. Detected recorders are listed here.
3.
Select a recorder and click
Connect
(
) to establish a communication link.
4.
Click the
System
tab, set the time and date (manually or synchronized with your PC).
5.
Click
Configuration Wizard
on the Task Overview tab. Either load a factory set
configuration and make changes to it or click
Next
to create your own configuration.
7.
Configure connected triggers (maximum seven, Event Trigger configuration is limited).
8.
Define up to eight schedules (optional).
9.
Configure up to four connected cameras.
10.
Enable GPS, if installed.
The
Time
and
Location
fields display data when the recorder detects the HTR4GPS
module. This information updates once per second to provide a visual confirmation that
your GPS system is working correctly.
Click
Next
.
6.
Set the recorder settings:
Recorder name
Record Delay (amount of time
the recorder continues to record
after the last record rule ends)
Standby Delay (amount of time
before the recorder goes into
Sleep mode after all wakeup
conditions are gone)
Recording Mode. Set to
Recycle
(recommended); to have the
system record over the oldest
data when the hard drive is full.
Click
Next
.
a.
Select a trigger from the list, then
name it, enable it and set the
property (active high or low).
Enable at least one trigger to wake
up the recorder when detected.
b.
Test trigger connections by
activating the trigger. Note the
status changes on the Trigger list.
c.
Click
Next
.
These schedules will define what days
and times the HTR4 Recorder can
record data.
You can set up schedules for specific
days or for a range of days.
You can also set up a
Wakeup
schedule which defines the time when
the recorder should be awake,
regardless of active triggers.
Click
Next
.
a.
Connected cameras automatically
populate the camera list on the
Camera Summary screen.
b.
Select a camera from the list.
Check your camera connections if
a camera image does not appear
within 30 seconds of selecting it.
c.
Name the camera and enable
audio to be recorded with video
from the camera (if supported).
d.
Repeat these steps for each
connected camera.
e.
Click
View Coverage Area
to test
the camera coverage. Cameras
will appear in the quad screen in
the order connected. Use the
quad view as a reference to help
re-position your cameras, as
required. Click
Save Snapshot
to
save a .jpg of the current view.
Click
Close
when you are
satisfied with the coverage.
f.
Click
Next
.
Check
Record GPS data when a rule
is active
to have the recorder collect
GPS data (position and local time).
The Status box displays the current
status of the HTR4GPS unit.