Draining Fuel 1. Turn fuel lever to OFF position. 2. Run engine until it stops due to lack of fuel. 3. Place suitable container underneath drain hole to catch fuel. 4. Loosen bolt (underneath fuel sediment cup). FIGURE 40: Loosen Bolt to Drain Fuel 5. Turn fuel lever to ON position. FIGURE 41: Fuel Valve Lever - ON/OFF position 6. Allow fuel to drain into container. 7. To ensure all fuel is drained, carefully tip generator by pulling up on frame at side opposite of recoil starter handle. Storing Generator FIGURE 42: Tip Generator to Completely Drain Fuel 8. Allow fuel to completely drain into container. 9. When ready to put generator back into operation, refill with fresh fuel (see page 22). HW5500/5500E Portable Generator Owner's Manual www.honeywellgenerators.com 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

HW5500/5500E Portable Generator Owner’s Manual
www.honeywellgenerators.com
27
Storing Generator
Draining Fuel
1.
Turn fuel lever to OFF position.
2.
Run engine until it stops due to lack of fuel.
3.
Place suitable container underneath drain hole to
catch fuel.
4.
Loosen bolt (underneath fuel sediment cup).
5.
Turn fuel lever to ON position.
6.
Allow fuel to drain into container.
7.
To ensure all fuel is drained, carefully tip generator by
pulling up on frame at side opposite of recoil starter
handle.
8.
Allow fuel to completely drain into container.
9.
When ready to put generator back into operation, refill
with fresh fuel (see page 22).
FIGURE 40:
Loosen Bolt to Drain Fuel
FIGURE 41:
Fuel Valve Lever — ON/OFF position
FIGURE 42:
Tip Generator to Completely Drain Fuel