Honeywell VISTAKEY User Guide - Page 10
Output Device Control #77 - access control
View all Honeywell VISTAKEY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
User Commands (cont'd) #79 The #79 command is used to add, remove, or edit cards in the system's cardholder database. For instructions on using this command, refer to Performing Access Control Card Functions. Output Device Control (#77) The #77 Output Device Control may used to activate outputs, bypass zones, etc. under user control. The actions that may be activated by the user are relay commands, arm/disarm commands, zone bypassing commands, open/close access conditions, and access control commands. For the #77 command to be accepted, the following conditions must exist: • The user must have a level assignment of Master. • If the partition is armed, Armed Restriction is in effect, and the user issues an access command, the user must be authorized to disarm the partition for the command to be accepted. • The user must be assigned to the access point's partition to protect, bypass, or lock the access point or to set it to exit only. • To arm or disarm a partition, the user must be assigned to that partition. • The VISTA user number must be assigned to the partition to which the keypad belongs. • The VISTA user number must be assigned to a card with an access group assignment that includes the point to which access is being requested. • The VISTA user number does not have to be assigned to the partition to which the access point belongs to be granted access, but if not they will be denied access while the partition is armed when an armed restriction has been programmed. - 10 -