Husqvarna 536LiHD60X Owners Manual - Page 20
Troubleshooting schedule, Control Panel, Battery, Battery charger
View all Husqvarna 536LiHD60X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
MAINTENANCE Troubleshooting schedule Control Panel Troubleshooting takes place from the keypad. LED display Green activate LED flashing. Possible faults Low battery voltage. Overload. Error LED flashes. Temperature deviation The power trigger and the activate button are pressed at the same time. The machine does not run Dirt in battery connectors. Error LED is lit with red light. Service Possible action Charge the battery The cutting attachment is jammed. Release the cutting attachment. Allow the machine to cool down. Release the power trigger and the machine is active. Clean with compressed air or a soft brush. Contact your service agent. Troubleshooting the battery and/or the battery charger during charging. Battery LED display Green activate LED flashing. Error LED flashing Possible faults Low battery voltage. Temperature deviation Over voltage Error LED is lit Battery charger Cell difference too much (1V) Possible action Charge the battery Use the battery in surroundings where temperatures are between -10 °C (14 °F) and 40 °C (104 °F). Check that the mains voltage corresponds with that stated on the rating plate on the machine. Remove the battery from the battery charger. Contact your service agent. LED display Error LED flashing Error LED is lit Possible faults Temperature deviation Possible action Use the battery charger only when the surrounding temperature is between 5 °C (41 °F) and 40 °C (104 °F). Contact your service agent. 20 - English