Husqvarna 536LiHD60X Owners Manual - Page 20

Troubleshooting schedule, Control Panel, Battery, Battery charger

Page 20 highlights

MAINTENANCE Troubleshooting schedule Control Panel Troubleshooting takes place from the keypad. LED display Green activate LED flashing. Possible faults Low battery voltage. Overload. Error LED flashes. Temperature deviation The power trigger and the activate button are pressed at the same time. The machine does not run Dirt in battery connectors. Error LED is lit with red light. Service Possible action Charge the battery The cutting attachment is jammed. Release the cutting attachment. Allow the machine to cool down. Release the power trigger and the machine is active. Clean with compressed air or a soft brush. Contact your service agent. Troubleshooting the battery and/or the battery charger during charging. Battery LED display Green activate LED flashing. Error LED flashing Possible faults Low battery voltage. Temperature deviation Over voltage Error LED is lit Battery charger Cell difference too much (1V) Possible action Charge the battery Use the battery in surroundings where temperatures are between -10 °C (14 °F) and 40 °C (104 °F). Check that the mains voltage corresponds with that stated on the rating plate on the machine. Remove the battery from the battery charger. Contact your service agent. LED display Error LED flashing Error LED is lit Possible faults Temperature deviation Possible action Use the battery charger only when the surrounding temperature is between 5 °C (41 °F) and 40 °C (104 °F). Contact your service agent. 20 - English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

20 – English
MAINTENANCE
Troubleshooting schedule
Control Panel
Troubleshooting takes place from the keypad.
Troubleshooting the battery and/or the battery charger during charging.
Battery
Battery charger
LED display
Possible faults
Possible action
Green activate LED flashing.
Low battery voltage.
Charge the battery
Error LED flashes.
Overload.
The cutting attachment is jammed.
Release the cutting attachment.
Temperature deviation
Allow the machine to cool down.
The power trigger and the activate
button are pressed at the same time.
Release the power trigger and the
machine is active.
The machine does not run
Dirt in battery connectors.
Clean with compressed air or a soft
brush.
Error LED is lit with red light.
Service
Contact your service agent.
LED display
Possible faults
Possible action
Green activate LED flashing.
Low battery voltage.
Charge the battery
Error LED flashing
Temperature deviation
Use the battery in surroundings where
temperatures are between -10
°
C (14
°
F) and 40
°
C (104
°
F).
Over voltage
Check that the mains voltage
corresponds with that stated on the
rating plate on the machine.
Remove the battery from the battery
charger.
Error LED is lit
Cell difference too much (1V)
Contact your service agent.
LED display
Possible faults
Possible action
Error LED flashing
Temperature deviation
Use the battery charger only when
the surrounding temperature is
between 5
°
C (41
°
F) and 40
°
C
(104
°
F).
Error LED is lit