Page 16 highlights
4 REPEATER AND DUPLEX OPERATION Auto Repeater function (For only the USA version of IC-V86) The USA version of IC-V86 automatically activates the repeater settings (DUP- or DUP+ and tone encoder ON/OFF), when the operating frequency falls within the general repeater output frequency range. It deactivates them when outside of the range. 1. Hold down [ ] for 1 second to turn OFF the power. 2. While holding down [Y] and [Z], turn ON the power to enter the Initial Set mode. 3. Push [Y] or [Z] to select the Auto Repeater item (RPt). 4. Rotate [VOL] to set the Auto Repeater function to "R1," "R2" or "OF." •• "RPt.OF":The Auto Repeater function is OFF. •• "RPt.R1": T he Auto Repeater function is ON (For only duplex). •• "RPt.R2": T he Auto Repeater function is ON (For duplex and tone encoder). 5. Push [# ENT] to exit the Initial Set mode. Frequency range and offset direction Frequency range Duplex direction 145.200-145.495 MHz 146.610-146.995 MHz "-" is displayed. 147.000-147.395 MHz "+" is displayed. The "Auto repeater" item in the Initial Set mode Auto Repeater function is OFF. Auto Repeater function is ON (For only duplex). Auto Repeater function is ON (For duplex and tone encoder). 4-4