Icom IC-V3500 Advanced Manual - Page 69
Using the Initial Set mode, Initial Set mode items, Key-touch beep, Time-out timer, Auto Repeater
View all Icom IC-V3500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
8. SET MODES Using the Initial Set mode The initial Set mode can be accessed when the transceiver is turned ON, and allows you to set seldom-changed settings. In this way, you can "customize" the transceiver to suit your preference and operating style. 1. While holding down [SET LOCK], hold down [ ] for 1 second to enter the Initial Set mode. 2. Repeatedly push [SET LOCK] or [MONI ANM PA] to select the desired item. 3. Rotate [DIAL] to select an option or value. 4. Push [ ] to save and exit the Initial Set mode. Initial Set mode items NOTE: The default settings may differ, depending on the transceiver version. Key-touch beep (Default: ON) Turns the confirmation beeps ON or OFF. •• OF: No beep sounds. •• ON: A beep sounds when a key is pushed. AO AO MUTE MUTE NAR NAR MID MID LOW LOW LOCK ANM LOCK ANM SET MONI SET MONI Auto Power OFF (Default: OF) Selects whether or not to automatically turn OFF the transceiver after inactivity for this set period of time. LLWhen the function is ON, "AO" is displayed in the function display. LLBeeps sound when turning OFF the transceiver. If you operate the transceiver during this period of time, the Auto Power OFF timer is reset. •• OF: Does not turn OFF the transceiver. •• 30/1H/2H: Turns OFF the transceiver after inactivity for this set period of time (30 minutes, 1 hour, or 2 hours). Time-out timer (Default: OF) To prevent an accidental prolonged transmission, the transceiver has a Time-out Timer function. The function inhibits continuous transmissions longer than this set period of time. •• OF: Turns OFF the function. •• 1 ~ 30: Transmission is cut OFF after the set period of time ends (1 to 30 minutes). Approximately 10 seconds before the Time-out timer is activated, the transceiver sounds a beep tone as a warning. AO MUTE NAR MID LOW LOCK ANM SET MONI AO MUTE NAR MID LOW LOCK ANM SET MONI Repeater Lockout (Default: OF) Sets the transmit lockout (temporary transmission inhibit) capability. •• OF: Turns OFF the function. •• RP: Transmit capability is inhibited when a signal with an unmatched subaudible tone is received. •• BU: Transmit capability is inhibited when a signal is received. AO MUTE NAR MID LOW LOCK ANM SET MONI Auto Repeater (Default: R1) The Auto Repeater function automatically turns the duplex settings and the tone encoder ON or OFF. LLThis item is displayed in only the USA version. LLThe frequency offset and the Repeater Tone frequency are not changed by this function. Reset these frequencies, if necessary. •• OF: Turns OFF the function. •• R1: Turns ON the duplex settings only. •• R2: Turns ON the duplex settings and the tone encoder. Squelch delay (Default: S) Sets the squelch delay to short or long. The delay prevents the squelch from repeatedly opening and closing when receiving the same signal. •• S: Short squelch delay. •• L: Long squelch delay. AO MUTE NAR MID LOW LOCK ANM SET MONI MUTE NAR MID LOW LOCK SET ANM MONI DUP LOW DIGITAL PRIO AO BUSY T-SCAN TONE PRIO M/CALL SCAN V/ MHz MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz 8-5