    Intel® RAID Controller RS2WC040 Hardware User's Guide Intel Order Number: E64403-002
  • Intel RS2WC040 | Hardware User Guide - Page 2
    its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 2009-2010 by Intel Corporation. Portions Copyright 2005-2010 by LSI Corporation. All rights reserved. ii Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 3
    hardware guide for the Intel® RAID Controller RS2WC040, for use with the SAS and SATA disk drives. It contains installation instructions and specifications. For details on how to configure the storage adapters, and for an overview of the software drivers, see the Intel® RAID Software User's Guide on
  • Intel RS2WC040 | Hardware User Guide - Page 4
    iv Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 5
    SAS ...1 Intel® RAID Controller RS2WC040 2 Protocol Support ...2 Operating System Support 2 Usability ...3 SAS/SATA Features of the LSISAS2008 Controller 4 Chapter 2, Intel® RAID Controller RS2WC040 Hardware Installation 7 Requirements ...7 Installing the RAID Controller 7 Configuring the RAID
  • Intel RS2WC040 | Hardware User Guide - Page 6
    vi Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 7
    List of Figures Figure 1. Changing the bracket 8 Figure 2. Installing the Intel® RAID Controller RS2WC040 9 Figure 3. Connecting Cables between the RAID Controller and Drives/Backplane 10 Figure 4. Card Layout...13 Intel® RAID Controller RS2WC040 Hardware User's Guide vii
  • Intel RS2WC040 | Hardware User Guide - Page 8
    viii Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 9
    List of Tables Table 1. Jumper Description 13 Table 2. Technical Specifications 14 Table 3. Array Performance Features 14 Table 4. Fault Tolerance Features 15 Table 5. Electrical Characteristics 17 Intel® RAID Controller RS2WC040 Hardware User's Guide ix
  • Intel RS2WC040 | Hardware User Guide - Page 10
    x Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 11
    1 Overview The Intel® RAID Controller RS2WC040 is an intelligent PCI Express* 2.0-compliant SAS/SATA II RAID controller that offers reliability, good performance, and fault-tolerant disk subsystem management. This is a RAID solution that meets the internal storage needs of workgroup, department, or
  • Intel RS2WC040 | Hardware User Guide - Page 12
    Intel® RAID Controller RS2WC040 The Intel® RAID Controller RS2WC040 is a PCI* Express 2.0, half-size, low profile RAID controller based on the LSISAS2008 PCI Express-SAS/SATA I/O Processor chip, providing both a SAS controller and RAID engine. With four independent ports supporting 6 Gb/s and 3 Gb/s
  • Intel RS2WC040 | Hardware User Guide - Page 13
    System List for the Intel® RAID Controller RS2WC040. Usability • The card ships with both a standard and a low-profile bracket. • Small, thin cabling with up to 6.0 Gb/s serial, point-to-point data transfer rates • Support for non-disk devices and mixed capacity drives • Support for intelligent XOR
  • Intel RS2WC040 | Hardware User Guide - Page 14
    of the LSISAS2008 Controller • Provides eight independent phys, each supporting 6 Gb/s and 3 Gb/s SAS data transfers per PHY, only four phys are utilized by the RAID adapter. • Supports SSP to enable communication with other SAS devices. 4 Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 15
    disk in an array. • Migration and OCE cannot be done on Spanned Arrays (RAID 10 and 50). • Migrations supported are RAID 1 to RAID 0, RAID 5 to RAID 0 • With OCE, migrations supported are RAID 0 to RAID 1, RAID 0 to RAID 5, and RAID 1 to RAID 5. Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 16
    6 Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 17
    Intel® RAID Controller RS2WC040 with the provided cable • A host system with an available x8 or x16 PCI-Express* slot • The Resource CD, which contains drivers and documentation • SAS or SATA 3.0 hard drives Note: SATA II is the only type of SATA supported by this RAID Controller. In addition, Intel
  • Intel RS2WC040 | Hardware User Guide - Page 18
    the bracket 4. Install the RAID controller into an available server system x8 or x16 PCI-Express* slot (see Figure 2). To locate an appropriate slot and for instructions on installing an add-in card, see your server system documentation. 8 Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 19
    foot if you are using a backplane. ✧ Do not use cross-over cables. ✧ Only connect to a SATA drive, SAS or SATA backplane, or an expander device. ✧ Route the cables carefully. ✧ Check that the controller and cables are all properly attached. Intel® RAID Controller RS2WC040 Hardware User's Guide 9
  • Intel RS2WC040 | Hardware User Guide - Page 20
    C B Ports 0-3 C AF003351 Figure 3. Connecting Cables between the RAID Controller and Drives/Backplane 6. Install the server system cover and connect the power cords. For instructions, see your server system documentation. 10 Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 21
    then display the Intel® RAID Controller RS2WC040 number and firmware version. The numbering of the RAID controller follows the PCI slot scanning order used by the server board. 3. See the Quick Start User's Guide and the Software User's Guide for instructions to configure the RAID controller and to
  • Intel RS2WC040 | Hardware User Guide - Page 22
    12 Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 23
    3 Intel® RAID Controller RS2WC040 Characteristics Figure 4. Card Layout Table 1. Jumper Description Jumper Type J1 16-pin header (Not populated) J2 10-pin header (Not populated) J3 4-pin connector J4 x4 Mini-SAS (SFF-8087) J6 PCI* Express Gen 2 x8 board edge connector J7 3-pin
  • Intel RS2WC040 | Hardware User Guide - Page 24
    Operating voltage Card size Array interface to host SAS/SATA bus speed SAS/SATA ports Physical and virtual drive support Firmware Compatible devices Cabling Redundant configuration Enclosure management Enclosure support Intel® RAID Controller RS2WC040 LSI*SAS2008 PCI*Express-SAS/SATA I/O Processor
  • Intel RS2WC040 | Hardware User Guide - Page 25
    Specification Self Monitoring Analysis and Reporting Technology (SMART) support Drive Replacement Drive Rebuild Using Hot Spares Intel® RAID Controller RS2WC040 • Detects up to 70% of predictable disk drive failures • Monitors the internal performance of all motors, heads, and drive electronics
  • Intel RS2WC040 | Hardware User Guide - Page 26
    support Error Checking and Indication Intel® RAID Controller RS2WC040 • Detects up to 70% of predictable disk drive failures • Monitors the internal performance retries • Logs in NVRAM, event log, CIM, S.M.A.R.T, Intel® RAID Web Console 2 16 Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 27
    flammability rating 94 V0. Each bare board is marked with the supplier name or trademark, type, and UL flammability rating. For the boards installed in a PCI bus slot, all voltages are lower than the SELV 42.4 V limit. Intel® RAID Controller RS2WC040 Hardware User's Guide 17
  • Intel RS2WC040 | Hardware User Guide - Page 28
    18 Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 29
    the server board or disconnecting a peripheral device from the computer. • To help service the computer system yourself, except as explained in this guide and elsewhere in Intel documentation. Always follow installation and service instructions Intel® RAID Controller RS2WC040 Hardware User's Guide 19
  • Intel RS2WC040 | Hardware User Guide - Page 30
    You can do so by touching an unpainted metal surface, such as the metal around the card-slot openings at the back of the computer. • As you continue to work inside the computer area. If possible, use antistatic floor pads and workbench pads. 20 Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 31
    performing any of the instructions. See also Intel® Server Boards and Server Chassis Safety Information on the Resource CD and/or at http://support.intel.com/support off all peripheral devices connected to , add-in cards, and other components Intel® RAID Controller RS2WC040 Hardware User's Guide 21
  • Intel RS2WC040 | Hardware User Guide - Page 32
    and heat sink may be hot if the system has been auch die Sicherheitshinweise zu Intel-Serverplatinen und -Servergehäusen auf der Ressourcen-CD oder unter http://support.intel.com/support/motherboards/server/sb/cs äß montiertes Gehäuse ein. 22 Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 33
    ce document avant de suivre toute instruction. Consultez Intel® Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site http://support.intel.com/support/motherboards/server/sb/cs-010770.htm Intel® RAID Controller RS2WC040 Hardware User's Guide 23
  • Intel RS2WC040 | Hardware User Guide - Page 34
    ème. Pour mettre le système hors tension, vous devez débrancher chaque câble d'alimentation de sa prise. C'est le câble d'alimentation qui est considéré comme le moyen de se déconnecter du d'alimentation c. a. et câbles externes au système. 24 Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 35
    de las instrucciones. Vea Intel® Server Boards and Server Chassis Safety Information en el CD Resource y/o en http://support.intel.com/support/motherboards/server/sb/cs-010770 guarde todos los tornillos de las tapas.Extraiga las tapas. Intel® RAID Controller RS2WC040 Hardware User's Guide 25
  • Intel RS2WC040 | Hardware User Guide - Page 36
    dispositivo d'interruzione dell'alimentazione principale (in c.a.). La presa alla quale si collega il sistema deve essere installata vicino all'unità e deve essere facilmente accessibile. 26 Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 37
    dissipatore di calore potrebbero essere surriscaldati. Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. Intel® RAID Controller RS2WC040 Hardware User's Guide 27
  • Intel RS2WC040 | Hardware User Guide - Page 38
    28 Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 39
    on the backplane to change the targets. For instructions to instructions, see your server system documentation. 7. Plug in and power on the system. The controller detects the RAID configuration from the configuration data on the drives (COD). Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 40
    Install the server system cover. For instructions, see your server system documentation. 10. Plug in and power on the system. When you start the system, the controller detects the RAID configuration from the configuration data on the drives. 30 Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 41
    Appendix C: Regulatory and Certification Information This RAID Controller Card complies with the following safety and electromagnetic compatibility (EMC) regulations. Product Safety Compliance • (Canada) • CE Mark (Europe) • KCC Mark (Korea) Intel® RAID Controller RS2WC040 Hardware User's Guide 31
  • Intel RS2WC040 | Hardware User Guide - Page 42
    of this device is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept Tick Mark Australia Note: This controller is EU RoHS compliant as per EU Directive 2002/95/EC. 32 Intel® RAID Controller RS2WC040 Hardware User's Guide
  • Intel RS2WC040 | Hardware User Guide - Page 43
    Compatibility Notices FCC Verification Statement (USA) : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device /95/EC) Intel® RAID Controller RS2WC040 Hardware User's Guide 33
  • Intel RS2WC040 | Hardware User Guide - Page 44
    and EMC Directive (2004/108/EC). The product has been marked with the CE Mark to illustrate its compliance. 34 Intel® RAID Controller RS2WC040 Hardware User's Guide
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

Intel
®
RAID Controller RS2WC040
Hardware User’s Guide
Intel Order Number: E64403-002