    Intel® Entry Server Chassis SC5275-E User Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products Order Number: C50277-001
  • Intel SC5275-E | User Guide - Page 2
    are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright © 2004, Intel Corporation. All Rights Reserved. Intel® Entry Server Chassis SC5275-E User Guide ii
  • Intel SC5275-E | User Guide - Page 3
    you may need, troubleshooting information, and instructions on how to add and replace components on the Intel® Entry Server Chassis SC5275-E. For the latest version of this manual, refer to http://support.intel.com/support/motherboards/server/chassis/SC5275E. Manual Organization Chapter 1 provides
  • Intel SC5275-E | User Guide - Page 4
    system tours and interactive repair information Intel® Server Chassis SC5275-E Technical Product Specification at http://support.intel.com/support/motherboards/server/chassis/ SC5275E. Intel® Entry Server Chassis SC5275-E Quick Start User's Guide in the product box http://support.intel.com/support
  • Intel SC5275-E | User Guide - Page 5
    ) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist Intel® Entry Server Chassis SC5275-E User Guide v
  • Intel SC5275-E | User Guide - Page 6
    before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http://support.intel.com/support/motherboards/server/safecert.htm. The power supply in this product contains no user-serviceable parts. There may be more than
  • Intel SC5275-E | User Guide - Page 7
    Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu IntelServerplatinen und -Servergehäusen unter http://support.intel.com/support/motherboards/server/safecert.htm. Intel® Entry Server Chassis SC5275-E User Guide vii
  • Intel SC5275-E | User Guide - Page 8
    anzubringen: 1. Vergewissern Sie sich, daß Sie keine Werkzeuge oder Teile im Innern des Systems zurückgelassen haben. 2. Überprüfen Sie alle Kabel, Zusatzkarten und andere Komponenten auf Batterie besteht Explosionsgefahr. Die Batterie darf nur Intel® Entry Server Chassis SC5275-E User Guide viii
  • Intel SC5275-E | User Guide - Page 9
    avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le site http://support.intel.com/support/motherboards/server/safecert.htm. Le bloc devez débrancher chaque câble d'alimentation de sa prise. Intel® Entry Server Chassis SC5275-E User Guide ix
  • Intel SC5275-E | User Guide - Page 10
    type ou d'un type équivalent recommandé par le fabricant. Disposez des piles usées selon les instructions du fabricant. Le système a été conçu pour fonctionner dans un cadre de travail normal. de surtension, et de débrancher toutes les lignes de Intel® Entry Server Chassis SC5275-E User Guide x
  • Intel SC5275-E | User Guide - Page 11
    Intel Server Boards and Server Chassis Safety Information en en http://support.intel.com/support/motherboards/server/ ello: 1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y Intel® Entry Server Chassis SC5275-E User Guide xi
  • Intel SC5275-E | User Guide - Page 12
    para funcionar en un entorno de trabajo normal. Escoja un lugar: Limpio y libre de partículas en suspensión (salvo el polvo normal). Bien ventilado y alejado de fuentes de alimentazione in c.a. dalle prese a muro o dall'alimentazione di corrente. Intel® Entry Server Chassis SC5275-E User Guide xii
  • Intel SC5275-E | User Guide - Page 13
    tipo. Scegliere una postazione che sia: Pulita e libera da particelle in sospensione (a parte la normale polvere presente nell'ambiente). Ben ventilata e lontana da fonti di calore, rappresentano il mezzo principale di scollegamento del sistema. Intel® Entry Server Chassis SC5275-E User Guide xiii
  • Intel SC5275-E | User Guide - Page 14
    Preface Intel® Entry Server Chassis SC5275-E User Guide xiv
  • Intel SC5275-E | User Guide - Page 15
    inch Hard Drive Bays 5 Optional 3.5-inch Hot Swap Drive Bay 5 Accessories and Order Codes 5 Power Supply ...6 Checking the Power Cord 6 Chassis Security ...6 Monitoring ...6 Mechanical Locks...7 2 Setting Up the Chassis 9 Tools and Supplies Needed ...9 Installation Safety Instructions 9 Safety
  • Intel SC5275-E | User Guide - Page 16
    Service 55 Telephone Support...55 Returning a Defective Product 55 Figures Figure 1. Screw Description...1 Figure 2. Mechanical Locks ...7 Figure 3. Removing the Access Cover 11 Figure 4. Removing the Front Bezel 12 Figure 5. Installing the I/O Shield 13 Intel® Entry Server Chassis SC5275
  • Intel SC5275-E | User Guide - Page 17
    8. Feature Summary ...1 LED Description ...3 Accessories and Order Codes 5 Power Supply System Output Capability 39 Environmental Specifications 40 Power Usage Worksheet 1 43 Power Usage Worksheet 2 44 Product Certification Markings 46 Intel® Entry Server Chassis SC5275-E User Guide xvii
  • Intel SC5275-E | User Guide - Page 18
    Contents Intel® Entry Server Chassis SC5275-E User Guide xviii
  • Intel SC5275-E | User Guide - Page 19
    can be used; unused expansion slots must have a slot cover Covers installed over the external access. Power Supply 600 Watt PFC power supply. Cooling Two system fans inside the chassis and one power supply fan provide cooling and airflow. Intel® Entry Server Chassis SC5275-E User Guide 1
  • Intel SC5275-E | User Guide - Page 20
    Description Chassis Front View A B C D E F TP00053 A. Front panel controls and indicators B. 5.25-inch removable media drive bays C. 3.5-inch removable media drive bay D. Internal hard drive bay cage (behind door) E. Security lock F. USB port Intel® Entry Server Chassis SC5275-E User Guide 2
  • Intel SC5275-E | User Guide - Page 21
    drive activity Fault No activity System ready (not supported by all server boards) Processor or memory disabled Temperature or voltage critical fault; CPU/Terminator missing Power fault; Fan fault; Temperature or voltage non-critical fault Fatal error during POST Intel® Entry Server Chassis SC5275
  • Intel SC5275-E | User Guide - Page 22
    power connector D. Power supply E. Fan F. I/O ports* G. Expansion slot covers H. ICMB or external SCSI knockout I. Serial B port knockout J. Location to install padlock loop K. Chassis intrusion switch * Items shown may be different in your chassis. Intel® Entry Server Chassis SC5275-E User Guide
  • Intel SC5275-E | User Guide - Page 23
    Upgrade Kit* SATA Hot Swap Drive Bay Upgrade Kit* Intel® Workstation Cooling Kit ICMB Board Kit* External SCSI Adapter Cable* * Not available for use with all server boards. Order Code AXX6SCSIDB AXX6SATADB APT2WKTCOOLKIT AXX2ICMBKIT AXXEXTSCSICBL Intel® Entry Server Chassis SC5275-E User Guide 5
  • Intel SC5275-E | User Guide - Page 24
    management controller on the server board. Server management software can be programmed to respond to an intrusion in a number of ways. This feature is not supported on all server boards. See your server board documentation for more information. Intel® Entry Server Chassis SC5275-E User Guide 6
  • Intel SC5275-E | User Guide - Page 25
    hard drives and the interior of the chassis. A padlock loop is included with the chassis and can be installed at the rear of the chassis. A B A. Location to install padlock loop B. Front bezel locked position Figure 2. Mechanical Locks TP00055 Intel® Entry Server Chassis SC5275-E User Guide 7
  • Intel SC5275-E | User Guide - Page 26
    1 Chassis Description Intel® Entry Server Chassis SC5275-E User Guide 8
  • Intel SC5275-E | User Guide - Page 27
    lines connected to I/O connectors or ports on the back of the chassis. Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis ground-any unpainted metal surface-when handling components. Intel® Entry Server Chassis SC5275-E User Guide 9
  • Intel SC5275-E | User Guide - Page 28
    battery. Use a conductive foam pad if available. Do not slide board over any surface. For proper cooling and airflow, always install the access cover before turning on the server. Operating it without the cover in place can damage system parts. Intel® Entry Server Chassis SC5275-E User Guide 10
  • Intel SC5275-E | User Guide - Page 29
    the figure). 4. Pull the entire cover upward, straight away from the chassis, to disengage the rows of tabs from the notches in the top and bottom edges of the chassis. Set the cover aside. 2 1 1 3 2 TP00057 Figure 3. Removing the Access Cover Intel® Entry Server Chassis SC5275-E User Guide 11
  • Intel SC5275-E | User Guide - Page 30
    up in the following figure). See number 1 in the figure. 2. Remove the bezel from the tabs at the right side of the chassis (facing down in the following figure). See number 2 in the figure. 1 1 2 2 TP00086 Figure 4. Removing the Front Bezel Intel® Entry Server Chassis SC5275-E User Guide 12
  • Intel SC5275-E | User Guide - Page 31
    the lip of the shield rests on the inner chassis wall. 4. Hold the shield in place, and push it firmly into the opening until it is seated. Make sure the I/O shield snaps into place all the way around. Figure 5. Installing the I/O Shield TP00074 Intel® Entry Server Chassis SC5275-E User Guide 13
  • Intel SC5275-E | User Guide - Page 32
    the 3.5-inch floppy drive from its protective wrapper and place it on an anti-static surface. 6. Record the drive model and serial numbers in your equipment log. 7. Set any jumpers or switches according to the drive manufacturer's instructions. Intel® Entry Server Chassis SC5275-E User Guide 14
  • Intel SC5275-E | User Guide - Page 33
    of devices you can install depends on: The number supported by the bus on your server board The number of physical drive bays available The combination of SCSI and IDE devices The amount of power required by other components in your chassis. Intel® Entry Server Chassis SC5275-E User Guide 15
  • Intel SC5275-E | User Guide - Page 34
    same bay. 1. Remove the EMI shield by using the finger-slots to grasp it and pull it straight out. Save the shield in case you later remove the peripheral. 2. Remove the plastic filler panel from the bezel. TP00061 Figure 8. Removing EMI Shields Intel® Entry Server Chassis SC5275-E User Guide 16
  • Intel SC5275-E | User Guide - Page 35
    that the left and right rails mirror each other. The rails must be installed with the metal flange with the screw holes to the front of the drive and the flap with the screw holes must point away from the drive. B Figure 9. Slide Rails TP00081 Intel® Entry Server Chassis SC5275-E User Guide 17
  • Intel SC5275-E | User Guide - Page 36
    screws for each slide rail to attach the device at the front of the chassis. 9. Connect the data and power cables to the drive. The connectors are keyed and can be inserted in only one way. TP00065 Figure 10. Installing a Removable Media Device Intel® Entry Server Chassis SC5275-E User Guide 18
  • Intel SC5275-E | User Guide - Page 37
    the drive cage out of the chassis. You may need to push the cage out from the inside of the chassis. TP00062 Figure 11. Removing a Drive Cage 3. For additional information, read and follow the instructions provided with the server board Quick Start User's Guide. These instructions will guide you
  • Intel SC5275-E | User Guide - Page 38
    Remove the drive from its protective wrapper and place it on an antistatic surface. 4. Record the drive model and serial numbers in your equipment log. 5. Set any jumpers or switches on the drive according to the drive manufacturer's instructions. Intel® Entry Server Chassis SC5275-E User Guide 20
  • Intel SC5275-E | User Guide - Page 39
    the drive. 9. Use four screws (screw A), attach the drive to the cage. A A B TP00063 A. Screw tabs. Point up when installing drives. B. Airflow baffles (one at top of cage, the other at the bottom of cage) Figure 12. Attaching a Hard Drive to a Cage Intel® Entry Server Chassis SC5275-E User Guide
  • Intel SC5275-E | User Guide - Page 40
    the chassis. 11. Insert and tighten the four screws removed in Step 1. 12. Attach data and power cables to the drive(s). A B TP00066 A. Data and power cables B. Screw tabs. Point toward top of chassis. Figure 13. Installing the Hard Drive Bay Cage Intel® Entry Server Chassis SC5275-E User Guide
  • Intel SC5275-E | User Guide - Page 41
    the chassis intrusion cable to the server board. 8. If desired, connect the serial port cable to the server board and mount it on the rear of the chassis. ✏ NOTE Use caution in routing cables to ensure they do not obstruct the airflow from the fans. Intel® Entry Server Chassis SC5275-E User Guide
  • Intel SC5275-E | User Guide - Page 42
    the threaded hole, and tighten it firmly. Attach cables if necessary. ✏ NOTE When removing a full-length add-in card, you must pull back on the latch on the plastic card guide at the front of the chassis to release the card from the card guide. Intel® Entry Server Chassis SC5275-E User Guide 24
  • Intel SC5275-E | User Guide - Page 43
    2 Setting Up the Chassis A B C A. Snap-in slot cover B. Tapered foot C. Slot Figure 14. Installing an Add-in Board OM11961 Intel® Entry Server Chassis SC5275-E User Guide 25
  • Intel SC5275-E | User Guide - Page 44
    in the figure below) over the side of the chassis to engage the two tabs. See number 3 in the figure. The installation of the chassis access cover will prevent the bezel from being removed. 3 3 1 2 2 TP00056 Figure 15. Installing the Front Bezel Intel® Entry Server Chassis SC5275-E User Guide 26
  • Intel SC5275-E | User Guide - Page 45
    latches to the right to the "lock" position (letter B in figure). For additional security, you can also replace the shipping screws if desired. B A B TP00067 Figure 16. Installing the Access Cover Intel® Entry Server Chassis SC5275-E User Guide 27
  • Intel SC5275-E | User Guide - Page 46
  • Intel SC5275-E | User Guide - Page 47
    , personal injury or equipment damage can result. Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servicing should be done by technically qualified personnel. Intel® Entry Server Chassis SC5275-E User Guide 29
  • Intel SC5275-E | User Guide - Page 48
    pad if available but not the board wrapper. Do not slide board over any surface. For proper cooling and airflow, always install the access cover before turning on the server. Operating the server without the cover in place can damage system parts. Intel® Entry Server Chassis SC5275-E User Guide 30
  • Intel SC5275-E | User Guide - Page 49
    push the cage out from the back. 7. Use a flat-head screwdriver to pry up the four nylon rivets that hold the fan in place. 8. Slide the fan out through the fan opening. TP00078 Figure 17. Replacing the Front System Fan in a Standard Drive Cage Intel® Entry Server Chassis SC5275-E User Guide 31
  • Intel SC5275-E | User Guide - Page 50
    hard drive bay cage. 11. Replace the hard drive bay cage in the chassis. Make sure the fan opening faces the bottom of the chassis. 12. Connect the fan cable to the server board and reconnect the hard drives. 13. Replace the bezel. 14. Replace the access cover. Replacing a Rear System Fan 1. Remove
  • Intel SC5275-E | User Guide - Page 51
    the chassis). 9. Connect the power cables to the server board and peripherals. 10. Replace the access cover. 11. Connect the A/C power to the power supply. A A A A A A A. Screw locations Figure 18. Replacing the AC Power Supply TP00068 Intel® Entry Server Chassis SC5275-E User Guide 33
  • Intel SC5275-E | User Guide - Page 52
    to the chassis. See number 1 in the figure below 7. Remove the front panel board through the access hole. See number 2 in the figure below 2 A 1 B TP00064 A. Right side of chassis B. Front of chassis Figure 20. Removing the Front Panel Board Intel® Entry Server Chassis SC5275-E User Guide 34
  • Intel SC5275-E | User Guide - Page 53
    the new front panel board in the chassis. 10. Insert and tighten the three screws removed earlier. TP00083 Figure 22. Inserting the Front Panel Board 11. Replace the right access cover. 12. Replace the bezel. 13. Replace the left access cover. Intel® Entry Server Chassis SC5275-E User Guide 35
  • Intel SC5275-E | User Guide - Page 54
    USB cable to the server board. A 3 1 2 1 TP00079 Figure 23. Installing the USB Cable 12. Install the bracket over the USB port at the front of the chassis. 13. Reinstall all add-in cards. 14. Replace the bezel. 15. Replace the access cover. Intel® Entry Server Chassis SC5275-E User Guide 36
  • Intel SC5275-E | User Guide - Page 55
    3 Maintaining Your Server Intel® Entry Server Chassis SC5275-E User Guide 37
  • Intel SC5275-E | User Guide - Page 56
  • Intel SC5275-E | User Guide - Page 57
    overload the power subsystem and may cause the power supplies to overheat and malfunction. The expansion slots on the server board are rated for no more than 25 Watts for any one slot. The average current usage per slot should not exceed 13 Watts. Intel® Entry Server Chassis SC5275-E User Guide 39
  • Intel SC5275-E | User Guide - Page 58
    System Environmental Specifications Table 5. Environmental Specifications Temperature Non-operating Operating -40 ° to 70 °C. 5 ° to 35 °C; derated 0.5 °C for every 1000 ft (305 m) to a maximum of 10 to 15 kilovolts (kV); no component damage. Intel® Entry Server Chassis SC5275-E User Guide 40
  • Intel SC5275-E | User Guide - Page 59
    Processor Speed and Cache Memory Video Display Keyboard Mouse Diskette Drive A CD-ROM Drive Additional 5.25" Peripheral Hard Disk Drive Hard Disk Drive Hard Disk Drive Hard Disk Drive Hard Disk Drive Hard Disk Drive Hard Disk Drive continued Intel® Entry Server Chassis SC5275-E User Guide 41
  • Intel SC5275-E | User Guide - Page 60
    Equipment Log and Worksheets Equipment Log (continued) Item Manufacturer Name and Model Number Serial Number Date Installed Intel® Entry Server Chassis SC5275-E User Guide 42
  • Intel SC5275-E | User Guide - Page 61
    Drive 3rd Hard Drive 4th Hard Drive 5th Hard Drive 6th Hard Drive Expansion Board 1 Expansion Board 2 Expansion Board 3 Expansion Board 4 Expansion Board 5 Expansion Board 6 Expansion Board 7 +3.3 V +5 V -5 V +12 V -12 V Total Current 5 V Standby Intel® Entry Server Chassis SC5275-E User Guide
  • Intel SC5275-E | User Guide - Page 62
    W (5 V standby) X (______ A) ________ W Total Combined Wattage ________ W CAUTION Do not exceed a combined power output of 120 Watts for the +5 V and +3.3 V outputs. Exceeding a combined 120 Watts will overload the power subsystem and Intel® Entry Server Chassis SC5275-E User Guide 44
  • Intel SC5275-E | User Guide - Page 63
    A Compliance The Entry Server Chassis SC5275-E has been has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed a compatible Intel® host system. For information on compatible host system(s) refer to Intel's Server Builder Web site
  • Intel SC5275-E | User Guide - Page 64
    Country Marking cULus Listing Marks USA/Canada GS Mark Germany CE Mark Europe FCC Marking (Class A) USA EMC Marking (Class A) VCCI Marking (Class A) Canada Japan Intel® Entry Server Chassis SC5275-E User Guide 46
  • Intel SC5275-E | User Guide - Page 65
    Korea China Electromagnetic Compatibility Notices FCC (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two , contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124 1-800-628-8686 Intel® Entry Server Chassis SC5275-E User Guide 47
  • Intel SC5275-E | User Guide - Page 66
    the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, compliance. Intel® Entry Server Chassis SC5275-E User Guide 48
  • Intel SC5275-E | User Guide - Page 67
    to the instruction manual. BSMI ( Intel representative 3. Name of Certification Recipient: Intel Corporation 4. Date of Manufacturer: Refer to date code on product 5. Manufacturer/Nation: Intel Corporation/Refer to country of origin marked on product Intel® Entry Server Chassis SC5275-E User Guide
  • Intel SC5275-E | User Guide - Page 68
    . Peripheral Storage Devicesmust be UL recognized or UL listed accessory and TUV or VDE licensed. Maximum power rating of any one device is 19 watts. Total server configuration is not to exceed the maximum loading conditions of the power supply. Intel® Entry Server Chassis SC5275-E User Guide 50
  • Intel SC5275-E | User Guide - Page 69
    support.intel.com/support/motherboards/server/chassis/SC5275E Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel -2-6830 3634 (manual toll free. 38 Intel® Entry Server Chassis SC5275-E User Guide 51
  • Intel SC5275-E | User Guide - Page 70
    -0-114- 114; once connected, dial 800-843-4481 Panama contact AT&T USA by dialing 00-800-001- 0109; once connected, dial 800-843-4481 Chile (Easter Island) contact AT an updated support contact list, see http://www.intel.com/support/9089.htm/ Intel® Entry Server Chassis SC5275-E User Guide 52
  • Intel SC5275-E | User Guide - Page 71
    Warranty does not cover damages due to external causes, including accident, problems with electrical power, usage not in accordance with product instructions, misuse, neglect, alteration, repair, improper installation, or improper testing. Intel® Entry Server Platform SR1325TP1-E User Guide 53
  • Intel SC5275-E | User Guide - Page 72
    system containing this product. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This limited warranty gives you specific shall control. Intel® Entry Server Chassis SC5275-E User Guide 54
  • Intel SC5275-E | User Guide - Page 73
    www.intel.com/), call your local distributor or an Intel Customer Support representative. See "Getting Help" for telephone numbers. Returning a Defective Product Before returning any product, call your authorized dealer/distribution authority. Intel® Entry Server Platform SR1325TP1-E User Guide 55
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

IntelĀ® Entry Server Chassis SC5275-E
User Guide
A Guide for Technically Qualified Assemblers of IntelĀ® Identified
Subassemblies/Products
Order Number:
C50277-001