Maintenance And Cleaning

Page 66 highlights

8 MAINTENANCE AND CLEANING Mechanical Inspection and Maintenance Electrical Inspection and Maintenance ❑ Inspect all bolts and rivets to ensure that they are securely tightened ❑ Check all functions: and functioning properly. 1. Head raises and lowers properly. ❑ Check sleep surfaces to ensure all slats are intact. 2. Foot raises and lowers properly. ❑ Check casters to ensure they lock, if applicable, and roll properly. 3. Bed ends raise and lower properly. Pass/Fail ❑ PASS: Bed and all components have passed all of the above inspection criteria and the bed is ready for placement into a client's home. ❑ FAIL: Bed, or any component, has failed any of the above inspection criteria. Tag the bed or component with a complete description of the failure(s) and have the bed serviced. 8.2 Cleaning the Beds WARNING! Risk of Injury or Damage To avoid injury or damage from liquid ingress during maintenance: - DO NOT spray water into any power supply connection ports. - The electronic motors, power supply and pendants are protected against the entrance of dust and water when properly attached. - Before disassembling or washing an electric bed, disconnect the power supply from the electrical outlet. Part No 1180159-E 65 Invacare® G5510 Bed

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

8
MAINTENANCE AND CLEANING
Part No 1180159-E
65
Invacare
®
G5510 Bed
Pass/Fail
PASS: Bed and all components have passed all of the above inspection criteria and the bed is ready for placement into a client’s home.
FAIL: Bed, or any component, has failed any of the above inspection criteria. Tag the bed or component with a complete description of the
failure(s) and have the bed serviced.
8.2
Cleaning the Beds
Mechanical Inspection and Maintenance
Electrical Inspection and Maintenance
Inspect all bolts and rivets to ensure that they are securely tightened
and functioning properly.
Check all functions:
1.
Head raises and lowers properly.
Check sleep surfaces to ensure all slats are intact.
2.
Foot raises and lowers properly.
Check casters to ensure they lock, if applicable, and roll properly.
3.
Bed ends raise and lower properly.
WARNING!
Risk of Injury or Damage
To avoid injury or damage from liquid ingress during maintenance:
- DO NOT spray water into any power supply connection ports.
- The electronic motors, power supply and pendants are protected against the entrance of dust and water when properly
attached.
- Before disassembling or washing an electric bed, disconnect the power supply from the electrical outlet.