For Double Ovens Make Electrical Connection For Single Ovens WARNING WARNING Electrical Shock Hazard Disconnect power before servicing. Use 8 gauge copper wire. Electrically ground oven. Failure to follow these instructions can result in death, fire, or electrical shock. This oven is manufactured with a neutral (white) power supply wire and a cabinet-connected green (or bare) ground wire twisted together. 1. Disconnect power. 2. Feed the flexible conduit from the oven through the opening in the cabinet. 3. Remove junction box cover if it is present. 4. Install a UL Listed or CSA Approved conduit connector to the junction box. A Electrical Shock Hazard Disconnect power before servicing. Use 12 gauge copper wire. Electrically ground oven. Failure to follow these instructions can result in death, fire, or electrical shock. 4-Wire Cable from Home Power Supply IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local codes do not allow grounding through neutral, New Branch circuit installations (1996 NEC), mobile homes and recreational vehicles, new construction, and in Canada. A B E F G A. UL Listed or CSA Approved conduit connector 5. Route the flexible conduit from the oven to the junction box through a UL Listed or CSA Approved conduit connector. 6. Tighten screws on conduit connector. 7. See the "Electrical Connection Options Chart" to complete installation for your type of electrical connection. Electrical Connection Options Chart If your home has: 4-wire Go to section: 4-Wire Cable from Home Power Supply 3-wire ½" (1.3 cm) 3-Wire Cable from Home Power Supply ½" (1.3 cm) H C I D A. Cable from home power supply B. Black wires C. Red wires D. 4-wire flexible conduit from oven E. Junction box F. White wires G. UL Listed wire connectors H. Green (or bare) ground wires I. UL Listed or CSA Approved conduit connector 1. Connect the 2 black wires (B) together using a UL Listed wire connector. 2. Connect the 2 red wires (C) together using a UL Listed wire connector. 3. Untwist white wire from green (or bare) ground wire coming from the oven. 4. Connect the 2 white wires (F) together using a UL Listed wire connector. 5. Connect the green (or bare) ground wire (H) from the oven cable to the green (or bare) ground wire (in the junction box) using a UL Listed wire connector. 6. Install junction box cover. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

13
Make Electrical Connection
For Double Ovens
For Single Ovens
This oven is manufactured with a neutral (white) power
supply wire and a cabinet-connected green (or bare)
ground wire twisted together.
1.
Disconnect power.
2.
Feed the flexible conduit from the oven through
the opening in the cabinet.
3.
Remove junction box cover if it is present.
4.
Install a UL Listed or CSA Approved conduit connector
to the junction box.
5.
Route the flexible conduit from the oven to the junction box
through a UL Listed or CSA Approved conduit connector.
6.
Tighten screws on conduit connector.
7.
See the “Electrical Connection Options Chart” to complete
installation for your type of electrical connection.
Electrical Connection Options Chart
If your home has:
Go to section:
4-wire
4-Wire Cable from Home
Power Supply
3-wire
3-Wire Cable from Home
Power Supply
4-Wire Cable from Home Power Supply
IMPORTANT:
Use the 4-wire cable from home power
supply in the U.S. where local codes do not allow grounding
through neutral, New Branch circuit installations (1996 NEC),
mobile homes and recreational vehicles, new construction,
and in Canada.
1.
Connect the 2 black wires (B) together using
a UL Listed wire connector.
2.
Connect the 2 red wires (C) together using
a UL Listed wire connector.
3.
Untwist white wire from green (or bare)
ground wire coming from the oven.
4.
Connect the 2 white wires (F) together using
a UL Listed wire connector.
5.
Connect the green (or bare) ground wire (H) from
the oven cable to the green (or bare) ground wire
(in the junction box) using a UL Listed wire connector.
6.
Install junction box cover.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 12 gauge copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death,
fire, or electrical shock.
A
A. UL Listed or CSA Approved conduit connector
½"
(1.3 cm)
½"
(1.3 cm)
A
D
F
H
B
C
E
G
I
A. Cable from home power supply
B. Black wires
C. Red wires
D. 4-wire flexible conduit
from oven
E. Junction box
F. White wires
G. UL Listed wire connectors
H. Green (or bare) ground wires
I.
UL Listed or CSA Approved