Konica Minolta AccurioPress 6120 EF-105 AccurioPress 6136/6136P/6120 User Guid - Page 13
CAUTION, correct position.
View all Konica Minolta AccurioPress 6120 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
2.2 Installation Procedures 2 5 Loosen the lock screw (purple) [1] by turning in the direction of the arrow. 6 Slide the fusing unit [3] in the direction indicated by the ar- row while holding both the front side [1] and the rear side [2] handles, then pull up and remove it. 7CAUTION - Fusing unit would be very hot, please be careful when handling it. 7 Holding the handle of the front side [1] and the rear side [2] with both hands then set the Fusing Unit EF-105 [3] to the correct position. Slide the Fusing Unit EF-105 in the direction of the arrow until it reaches to the rear end. 8 Push the lock screw (purple) [1], then tighten by rotating in the direction of the arrow. AccurioPress 6136/6136P/6120 2-4
AccurioPress 6136/6136P/6120
2-4
2.2
Installation Procedures
2
5
Loosen the lock screw (purple) [1] by turning in the direction
of the arrow.
6
Slide the fusing unit [3] in the direction indicated by the ar-
row while holding both the front side [1] and the rear side [2]
handles, then pull up and remove it.
7
CAUTION
-
Fusing unit would be very hot, please be careful when handling it.
7
Holding the handle of the front side [1] and the rear side [2]
with both hands then set the Fusing Unit EF-105 [3] to the
correct position.
Slide the Fusing Unit EF-105 in the direction of the arrow un-
til it reaches to the rear end.
8
Push the lock screw (purple) [1], then tighten by rotating in
the direction of the arrow.