Cleaning the separation module, Push the separation module up to snap out and lift it out of position.
View all Konica Minolta Kodak i1320 Plus manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Cleaning the separation module The separation module should be removed from the scanner for best cleaning results. NOTE: When removing or cleaning the separation module, it may be easier to access the separation module if you remove the input tray. To remove the input tray, gently push the input tray to the left or right to release the pin from the slot, and lift it out of position. 1. Push the separation module up to snap out and lift it out of position. 2. Manually rotate and wipe the separation module tires with a roller cleaning pad. A-61560 January 2010 3. Inspect the separation module. If the separation module tires show signs of wear or damage, replace the tires or the separation module. See "Replacement procedures" for more information. 4-3