Konica Minolta Kodak i750 User Guide - Page 51
Replacement procedures, Replacing the feed module or feed module tires
View all Konica Minolta Kodak i750 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
Replacement procedures Replacing the feed module or feed module tires This section provides procedures for replacing the following parts. Use the list below as a guideline for frequency of replacement. • Feed Module tires and Separation Roller tires - tire life will vary depending upon paper types, environment and cleanliness. Nominal tire life will be approximately 500,000 documents; results will vary. Degradation of feeder performance, multiple feeds, stoppages, etc. indicate a need to change tires. Change all the tires on the feed module and separation roller at the same time. • Feed Module and Separation Roller - it is recommended that you install a new feed module and separation roller approximately every 4th tire change. Install a new feed module and separation roller at the same time. • Pre-separation Pad - it is recommended that you change the preseparation pad approximately every 500,000 documents. • Imaging Guides - replace when the imaging guides are heavily scratched and defects show in the image. To replace the feed module or feed module tires: 1. Remove the output tray. 2. Lift up the printer access cover. 3. Open the pod. 5-12 A-61500 May 2010