Chapter 6 Permanent Parameters Table 6.2. Interface-independent Parameters (Sheet 8 of 8) Environment Parameter Value Factory setting Default operation for Y5 PDF direct printing 0: Enlarges or reduces the image to fit in the 0 current paper size. Loads paper from the current paper cassette. 1: Through the image. Loads paper which is the same size as the image. 2: Enlarges or reduces the image to fit in the current paper size. Loads Letter, A4 or A3 size paper depending on the image size. 3: Through the image. Loads Letter, A4 or A3 size paper depending on the image size. 8: Through the image. Loads paper from the current paper cassette. 9: Through the image. Loads Letter, Ledger or Legal size paper depending on the image size. 10: Enlarges or reduces the image to fit in the current paper size. Loads Letter, Ledger or Legal size paper depending on the image size. e-MPS error Y6 0: Does not print the error report and display 3 the error message. 1: Prints the error report. 2: Displays the error message. 3: Prints the error report and displays the error message. a Supported only by FS-1500 series, FS-1600 series, FS-3400 series, and FS-3600 series. b I0-Name of the partition in memory card The FRPO I0 specifies a memory card partition name to be automatically read at power up. Only one partition may be specified. The data read from the named partition at power up will be available to users accessing the currently-active interface. The command uses the following format: FRPO I0, 'partition-name'; Note that a comma must be placed after the I0 parameter. The partition name should not exceed 15 printable ASCII characters (20H through 7EH) and be enclosed by single or double quotation marks. Partition names are case-sensitive so the correct upper and lowercase characters must be used in the FRPO I0 string. The FRPO M2 parameter enables the printing system to read the partition name into a port apart from the currently active one. For instance, if the active port were the parallel port but the M2 parameter specified the serial port, then the memory card data would be available to users accessing the serial interface. c M1-Status send control The FRPO M1 parameter enables the user to receive printing system status information. By sending CTRL-T (Hex 14) from the host computer to the printing system. d M3-Host buffer mode The M3 parameter determines the automatic or fixed host buffer mode. If the M3 value is 0 (automatic), the first data arriving from the computer go into buffer #1, regardless of which interface they arrive on. While buffer #1 is in use, if data also begin to arrive on a second interface they are stored in buffer #2. The printing system will print these data after it has finished printing the job received through buffer #1. The general rule is that data go to the available buffer. If the M3 value is 1 (fixed), buffer #1 is fixed to receive only the data arriving in the parallel interface; and buffer #2 is fixed in the option interface (if installed). The first data arriving on one of the interfaces go into its fixed, dedicated buffer and the printing system begins printing these data and continues as above. The factory setting of the total host buffer size is 60 kilobytes or 500 kilobytes depending on the model. This can be altered by the FRPO H8 command. If you alter the buffer size, you must reset the printing system to bring the change in effect. e M5/M6/M7/M8-Host buffer size The printing system utilizes each one buffer for its interfaces. This enables simultaneous receiving of data from the different host computers. The FRPO M5, M6, M7, and M8 parameters determine the ratio among the sizes allocated to these buffers. Parameters M6 and M7 are provided for option interfaces. For example, to allocate the buffers with size ratio of 5:1, use the following format: !R! FRPO M3, 1; FRPO M5, 5; FRPO M6, 1; EXIT; f Ignored in some emulation modes. g Models of low-end category only. h A3/ledger models only. 6-12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260

Chapter 6 Permanent Parameters
6-12
Default operation for
PDF direct printing
Y5
0:
Enlarges or reduces the image to fit in the
current paper size. Loads paper from the
current paper cassette.
1:
Through the image. Loads paper which is the
same size as the image.
2:
Enlarges or reduces the image to fit in the
current paper size. Loads Letter, A4 or A3
size paper depending on the image size.
3:
Through the image. Loads Letter, A4 or A3
size paper depending on the image size.
8:
Through the image. Loads paper from the
current paper cassette.
9:
Through the image. Loads Letter, Ledger or
Legal size paper depending on the image
size.
10:
Enlarges or reduces the image to fit in the
current paper size. Loads Letter, Ledger or
Legal size paper depending on the image
size.
0
e-MPS error
Y6
0:
Does not print the error report and display
the error message.
1:
Prints the error report.
2:
Displays the error message.
3:
Prints the error report and displays the error
message.
3
a
Supported only by FS-1500 series, FS-1600 series, FS-3400 series, and FS-3600 series.
b
I0—Name of the partition in memory card
The FRPO I0 specifies a memory card partition name to be automatically read at power up. Only one
partition may be specified. The data read from the named partition at power up will be available to
users accessing the currently-active interface.
The command uses the following format:
FRPO I0, ’
partition-name
’;
Note that a comma must be placed after the I0 parameter. The partition name should not exceed 15
printable ASCII characters (20H through 7EH) and be enclosed by single or double quotation marks.
Partition names are case-sensitive so the correct upper and lowercase characters must be used in the
FRPO I0 string.
The FRPO M2 parameter enables the printing system to read the partition name into a port apart from
the currently active one. For instance, if the active port were the parallel port but the M2 parameter
specified the serial port, then the memory card data would be available to users accessing the serial
interface.
c
M1—Status send control
The FRPO M1 parameter enables the user to receive printing system status information. By sending
CTRL-T (Hex 14) from the host computer to the printing system.
d
M3—Host buffer mode
The M3 parameter determines the automatic or fixed host buffer mode.
If the M3 value is 0 (automatic), the first data arriving from the computer go into buffer #1, regardless
of which interface they arrive on. While buffer #1 is in use, if data also begin to arrive on a second
interface they are stored in buffer #2. The printing system will print these data after it has finished
printing the job received through buffer #1. The general rule is that data go to the available buffer.
If the M3 value is 1 (fixed), buffer #1 is fixed to receive only the data arriving in the parallel interface;
and buffer #2 is fixed in the option interface (if installed). The first data arriving on one of the
interfaces go into its fixed, dedicated buffer and the printing system begins printing these data and
continues as above.
The factory setting of the total host buffer size is 60 kilobytes or 500 kilobytes depending on the
model. This can be altered by the FRPO H8 command. If you alter the buffer size, you must reset the
printing system to bring the change in effect.
e
M5/M6/M7/M8—Host buffer size
The printing system utilizes each one buffer for its interfaces. This enables simultaneous receiving
of data from the different host computers. The FRPO M5, M6, M7, and M8 parameters determine
the ratio among the sizes allocated to these buffers. Parameters M6 and M7 are provided for option
interfaces.
For example, to allocate the buffers with size ratio of 5:1, use the following format:
!R! FRPO M3, 1; FRPO M5, 5; FRPO M6, 1; EXIT;
f
Ignored in some emulation modes.
g
Models of low-end category only.
h
A3/ledger models only.
Table 6.2.
Interface-independent Parameters (Sheet 8 of 8)
Environment
Parameter
Value
Factory setting