LG DLEX5101V Owner's Manual - Page 10
Installation Location Requirements - review
UPC - 048231010696
View all LG DLEX5101V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
IMPORTANT: Follow the operating and care instructions in this manual and your dryer will provide many years of reliable service. It is important that you review this entire manual before installing and using your dryer. Detailed instructions concerning electrical connections, gas connections, and exhaust requirements are provided on the following pages. INSTALLATION LOCATION REQUIREMENTS A location that allows for proper exhaust installation. A gas dryer must be exhausted to the outdoors. See Venting Requirements. A grounded electrical outlet located within 2 ft. (61 cm) of either side of the dryer. See Electrical Requirements. A sturdy floor to support the total dryer weight of 200 lbs (90.7 kg). The combined weight of a companion appliance should also be considered. A level floor with a maximum slope of 1 inch (2.5 cm) under entire dryer. If slope is greater than 1 inch (2.5 cm), install Extended Dryer Feet Kit. Clothes may not tumble properly, and automatic sensor cycles may not operate correctly if dryer is not level. For a garage installation, you will need to place the dryer at least 18 inches (46 cm) above the floor. If using a pedestal, you will need 18 inches (46 cm) to the bottom of the dryer. Do not operate your dryer at temperatures below 45º F (7º C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector. NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer. CLEARANCES 21 1⁄4" (54 cm) 14" max.* (35.6 cm) 45 7⁄16" (115.3 cm) 28 15⁄16" (73.4 cm) 50 1⁄4" (127.5 cm) 5"** (12.7 cm) Closet Door Vent Requirements Installation spacing for recessed area or closet installation The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0 inches (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons: Additional spacing should be considered for ease of installation and servicing. Additional clearances might be required for wall, door and floor moldings. Additional spacing should be considered on all sides of the dryer to reduce noise transfer. For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. Companion appliance spacing should also be considered. Suggestion: There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer of vibration from one to the other. Too much vibration could cause them to make noise or touch each other, causing paint damage and making even more noise. 10