LG LP1220GSR Owners Manual - Page 12
Window Vent Panel and Extensions
View all LG LP1220GSR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
12 INSTALLATION Window Vent Panel and Extensions The window installation kit allows you to install the air conditioner in most vertical-sliding windows 18″ to 50″ wide, or horizontal-sliding windows from 18″ to 50″ high. Panel A B C D Fig. Window opening 18″ 9″ 17″ 17″ 18″ √ a 19″ - 26″ √√ b 27″ - 34″ √ √c 35″ - 50″ √ √√d Panel B (9″) 1. Select the panels required based on the window opening, as shown above. 2. For longer window openings, assemble and adjust the panels to fit the window opening. Use type A screws (included) to fix the panels together at the proper length. Screw A Panel A (18″) Panel C (17″) Panel D (17″) 1 Window Vent Panel 3 Extension Panels Window Installation Kit (Includes 1 window vent panel and 3 extension panels) 18″ 19″ - 25″ 18″ For an 18″ window opening, use the window vent panel (Panel A) by itself. Fig. a Panel D 27″ - 34″ Panel D Panel A 27″ - 34″ For window openings from 27″ to 34″, use the window vent panel (Panel A) and extension Panel D. Fig. c 19″ - 25″ For window openings from 19″ to 25″, use the window vent panel (Panel A) and extension Panel B. Fig. b Panel C 35″ - 50″ Panel D Panel C Panel D 35″ - 50″ For window openings from 35″ to 50″, use the window vent panel (Panel A) and extension Panel C and Panel D. Fig. d