Abnormal state Command : z, ISM modeCommand: j p, z][ ][Set ID][ ][OK][Data][x] - stand
UPC - 719192185456
View all LG M4224C-BA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
L RS-232C Controlling the Multiple Product Transmission / Receiving Protocol 16. Abnormal state (Command : z) Abnormal State : Used to Read the power off status when Stand-by mode. Transmission [k][z][ ][Set ID][ ][Data][Cr] Data FF : Read 0 : Normal (Power on and signal exist) 1 : No signal (Power on) 2 : Turn the monitor off by remote control 3 : Turn the monitor off by sleep time function 4 : Turn the monitor off by RS-232C function 8 : Turn the monitor off by off time function 9 : Turn the monitor off by auto off function Acknowledgement [z][ ][Set ID][ ][OK][Data][x] 17. ISM mode(Command: j p) Used to select the afterimage preventing function. Transmission [j][p][ ][Set ID][ ][Data][Cr] Data 1H : Inversion 2H : Orbiter 4H : White Wash 8H : Normal 10H : Dot Wash Acknowledgement [p][ ][Set ID][ ][OK][Data][x] A12 L