LG WM2277HW Service Manual - Page 29

Heating Without Water, Drain Malfunction - hose

Page 29 highlights

HEATING WITHOUT WATER When pressing SPIN SPEED and SOIL LEVEL at the same time after draining, is the water level frequency 255? When pressing SPIN SPEED and SOIL LEVEL buttons NO at the same time while washing, is the water level frequency between 230 - 243 ? YES Replace the SENSOR SWITCH ASSEMBLY. Check the voltage between two pins while pressing the POWER button. Is the voltage 120 V AC? YES Replace the MAIN PWB ASSEMBLY. DRAIN MALFUNCTION Is the drain hose twisted or frozen? NO Is the impeller of the drain pump clogged? NO Is the connector disconnected, disassembled? NO Is the coil of the drain pump too high or low? (resistance of the coil is 10-20 Ω) NO YES Repair the DRAIN HOSE ASSEMBLY. YES Remove foreign material. YES Reconnect or repair the connector YES Replace the DRAIN PUMP ASSEMBLY. When checking voltage between connectors during NO spin, is the voltage 120 V AC as in the figure? Replace the MAIN PWB ASSEMBLY. 28

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

28
Replace the
SENSOR SWITCH
ASSEMBLY.
Replace the MAIN PWB
ASSEMBLY.
Repair the DRAIN HOSE
ASSEMBLY.
Remove foreign material.
Reconnect or repair the
connector
Replace the DRAIN
PUMP ASSEMBLY.
Replace the MAIN PWB
ASSEMBLY.
When
pressing SPIN SPEED and SOIL LEVEL at the
same time after draining, is
the water level frequency
255?
When pressing
SPIN SPEED and SOIL LEVEL
buttons
at the same time while washing, is the water level
frequency between 230 - 243 ?
Check the voltage between two pins while pressing
the POWER button. Is the voltage
120 V AC?
Is the drain hose twisted or frozen?
Is the impeller of the drain pump clogged?
Is the connector disconnected, disassembled?
Is the coil of the drain pump too high or low?
(resistance of the coil is 10-20 Ω)
When checking voltage between connectors during
spin, is the voltage 120 V AC as in the figure?
HEATING WITHOUT WATER
DRAIN MALFUNCTION