Lasko FH500 User Manual - Page 2

Warning

Page 2 highlights

WARNING IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, these instructions and warnings should always be followed to reduce the risk of fire, electrical shock and injury to persons: Read all instructions before using this Heater. WARNING • PLUG UNIT DIRECTLY INTO A 120V WALL OUTLET/RECEPTACLE ONLY. NEVER USE WITH AN EXTENSION CORD. DO NOT PLUG UNIT INTO ANY OTHER CORD CONNECTED DEVICE, SUCH AS A POWER STRIP, SURGE PROTECTOR, MULTIPLE OUTLET ADAPTER, CORD REEL OR OUTLET-TYPE AIR FRESHENER. THE USE OF SUCH DEVICES MAY CREATE A FIRE HAZARD. DO NOT PLUG MULTIPLE DEVICES IN THE SAME OUTLET OR ON SAME CIRCUIT AS UNIT. • FAULTY WALL OUTLET CONNECTIONS MAY CAUSE THE WALL OUTLET TO OVERHEAT. BE SURE THAT UNIT PLUG FITS TIGHTLY INTO OUTLET BEFORE EACH USE. DURING USE, CHECK TO MAKE CERTAIN THE UNIT PLUG IS NOT OVERHEATING. IF NECESSARY HAVE A QUALIFIED ELECTRICIAN CHECK AND/OR REPLACE THE WALL OUTLET. DO NOT USE THIS UNIT WITH ANY SOLID STATE SPEED CONTROL DEVICES. • Make certain that the power source conforms to the electrical requirements of the Unit. • Extreme caution is necessary when any Unit is used by or near children or invalids. The Unit should not be left operating unattended. Never leave children unattended when the unit is on or plugged in. • This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature. • DO NOT use the Unit in areas where gasoline, paint, or flammable liquids are used or stored. DO NOT use Unit in locations where flammable or explosive chemicals are stored, or in wet atmospheres. • Do not operate any Unit with a damaged cord or plug or after the Unit malfunctions, or has been dropped or damaged in any manner. To disconnect Unit, turn the Unit OFF then remove the plug from the outlet. • Always unplug Unit when not in use. Unplug power cord before servicing or moving the Unit. • Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock, fire, or damage the Unit. Do not block or tamper with the Unit in any manner while it is in operation. • Do not block air intakes or exhaust in any manner. Do not place on soft surfaces, like a bed, where openings may become blocked. Do not depend on the on/off switch as the sole means of disconnecting power when servicing or moving the unit. Always unplug the power cord. CAUTION • Always place the Unit on a stable, flat, level surface when operating, to avoid the chance of the Unit overturning. Locate the Power Cord so the Unit or other objects are not resting on it. DO NOT run Power Cord under carpeting. DO NOT cover Power Cord with throw rugs, runners, or similar coverings as this may cause cord to overheat. Arrange Power Cord away from room traffic and where it will not be tripped over. • This Unit is HOT when in use. To avoid burns, do not let bare skin touch hot surfaces. Always use handle when moving this Unit. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet (0.9 m) from the front of the Unit and keep them at least 1 foot (0.3 m) from the sides and rear. • This Unit is not intended for use in wet or damp locations. This Unit is not intended for use in bathrooms, laundry areas and similar indoor locations. NEVER locate a Unit where it may fall into a bathtub or other water container. • DO NOT use Unit outdoors. • This Unit is not suitable for use in agricultural facilities including areas where livestock, poultry or other animals are confined. Please refer to National Electric Code (NEC) Article 547-7 (2008), or applicable state or local codes or standards relating to electrical requirements for Agricultural Buildings. THIS UNIT DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547-7 (2008). • This Unit is not suitable for use in hazardous locations. Please refer to National Electric Code (NEC) Article 500 or applicable state or local codes or standards relating to electrical requirements for Hazardous locations. THIS UNIT DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008). NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/ TV technician for help. The user is cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the user's authority to operate this equipment. Please contact Customer Service at 800-233-0268 Monday through Friday from 8am to 5pm EST for assistance. SAVE THESE INSTRUCTIONS NEW 7/18 2 FH500ES MODELO FH500 ENSAMBLAJE 1. Cuidadosamente retire el unidad de la bolsa y de la caja de cartón. Para facilitar el ensamblaje, apoye el unidad de modo tal que la parrilla frontal y el panel de control apunten hacia arriba. 2. Introduzca el Cable Eléctrico a través del orificio grande en el ensamblaje de la Base. NOTA: El Canal para el Cable en la parte inferior de la base debe quedar hacia la parte trasera del unidad. (Figura 1) 3. Ensamble la Base al encajar el Lado A y el Lado B. (Figura 1) 4. Conecte la Base a la parte inferior del unidad Mediante el uso de 4 Tornillos de Apriete Manual, fije la Base al unidad. (Figura 2) Cable Eléctrico Base Lado A Base Canal para el Cable Figura 1 Tornillos de Base Lado B Figura 2 Apriete Manual FUNCIONAMIENTO 1. Coloque el Unidad sobre una superficie firme y plana. Los tacos de plástico o hule, tales como las patas de esta unidad, pueden pegarse a la superficie de los muebles y/o a los pisos de madera. La unidad podría dejar un residuo capaz de oscurecer, manchar o dejar marcas permanentes en el acabado de ciertas superficies de muebles, incluyendo superficies de madera y/o pisos de madera. 2. Conecte el cable a un tomacorriente de 120 Vca. Asegúrese que el enchufe encaje firmemente en el tomacorriente. Cuando los enchufes quedan flojos dentro de los tomacorrientes, podrían deslizarse parcial o completamente fuera del tomacorriente con el menor movimiento del cable adosado. Los tomacorrientes en este estado podrían sobrecalentarse y representar un peligro de incendio grave; si queda cubierto por una cortina o tela, el peligro de incendio es todavía mayor. 3. Cuando el unidad se conecte por primera vez, se oirá un "bip" y la Luz de Encendido se encenderá indicando que hay electricidad en la unidad. La Luz de Encendido permanecerá encendida hasta que el unidad sea desconectado del tomacorriente eléctrico. 4. ENCIENDA el Calefactor oprimiendo el Botón de Encendido del Calefactor ( ). 5. Al encender el Calefactor, la unidad estará en calor Alto (H3) (1 500 Watts). (Figura 3) 6. Presione el Botón de Modo de Calor ( ) para activar el calor Medio (H2). Presione nuevamente para activar el calor Bajo (H1). Presione una tercera vez para el Modo de Ventilador Calefactor (HF). Esto activa la configuración de calor alto (H3) y la velocidad de ventilador superbaja (F1) simultáneamente. Presione una cuarta vez para volver a activar el calor Alto (H3). 7. Para APAGAR el Calefactor, presione el Botón de Encendido del Calefactor ( ) y desconecte el Calefactor del tomacorriente eléctrico. 8. ENCIENDA el Ventilador oprimiendo el Botón de Encendido del Ventilador ( ). 9. Al encender el Ventilador, la unidad estará en Velocidad Alta (F4). 10. Presione el Botón de Modo de Ventilador ( ) para activar el Velacidad Media (F3). Presione nuevamente para activar el Bajo Velacidad (F2). Presione una tercera vez para Súper Baja Velocidad (F1). Presione una cuarta vez para volver a activar el Velocidad Alta (F4). 11. Para APAGAR el Ventilador, presione el Botón de Encendido del Ventilador ( ) y desconecte el unidad del tomacorriente eléctrico. AUTO ECO™ THERMOSTAT (Figura 3) Al presionar los botones ( ) o ( ) mientras está en cualquier función o velocidad del Calefactor, se activará la función Auto Eco™. 1. Para fijar una temperatura específica en la habitación, presione los bot- ones ( ) o ( ) hasta la temperatura deseada. La pantalla ahora reflejará el símbolo de Auto Eco™ y la temperatura destellará. El Calefactor está ahora en modo Auto Eco™. 2. Cuando se alcance la temperatura en la cual desea establecer la unidad, la temperatura fijada destellará varias veces y luego la pantalla volverá a indicar la temperatura ambiente actual y cambiará gradualmente a medida que cambie la temperatura ambiente. NOTA: La pantalla de la temperatura no indica la temperatura del aire caliente que emite el Calefactor. 3. Una vez que la temperatura ambiente alcance 2 grados por encima de la temperatura fijada, el calefactor se apagará. El Calefactor continuará operando durante 15 segundos después de que el elemento se ha apagado. 4. Si la temperatura ambiente es igual a la temperatura FIJADA, el calefactor operará en calor BAJO. 5. Si la temperatura ambiente es menos de la temperatura FIJADA en más de 3 grados, el calefactor operará en calor ALTO. Todo esto ocurre automáticamente con la tecnología Auto Eco™ de Lasko. Para desactivar la función Auto Eco™, apague el calefactor o presione el botón ( ). NOTA: En el modo Auto Eco™, el Calentador mostrará la temperatura am- biente actual en grados Fahrenheit. Presione los botones ( ) y ( ) al mismo tiempo para mostrar los grados Celsius. Presione los mismos dos botones juntos nuevamente para volver a mostrar los grados Fahrenheit. Figura 4 OSCILACIÓN Con el unidad encendido, oprima el Botón de Oscilación ( ) para activar y desactivar la función de oscilación. La función de oscilación puede utilizarse con cualquier modo de velocidad y/o de temporizador. FUNCIÓN DE TEMPORIZADOR (Figura 5) La función de temporizador puede ser activada cuando la pantalla del unidad está en cualquier función o velocidad. Esta función le permite fijar la cantidad de tiempo que el unidad estará funcionando antes de apagarse automáticamente, de 1 hora a 8 horas. Presionar el Botón de Temporizador ( ) aumentará la cantidad de tiempo en 1 hora cada vez que dicho botón sea oprimido. Después que la pantalla refleje 8 horas, si presiona el Botón de Temporizador ( ) una vez más, se reiniciará el unidad para función continua. La unidad se puede volver a encender presionando cualquiera de los Botones de Encendido ( ). Figura 3 NEW 7/18 Figura 5 SISTEMA DE FILTRO EZCLICK™ Pulse el botón del Filtro EZclick™ para liberar la cubierta del filtro permanente. Limpie el filtro con una aspiradora con cepillo, cada dos semanas; de esa manera, ayudará a mantener el desempeño óptimo del filtro. Recuerde limpiar el filtro antes de guardar la unidad al final de la temporada. 7 FH500ES

  • 1
  • 2
  • 3
  • 4

NEW 7/18
2
FH500ES
SAVE THESE INSTRUCTIONS
PLUG UNIT DIRECTLY INTO A 120V WALL OUTLET/RECEPTACLE ONLY. NEVER USE WITH AN EXTENSION CORD. DO NOT PLUG UNIT
INTO ANY OTHER CORD CONNECTED DEVICE, SUCH AS A POWER STRIP, SURGE PROTECTOR, MULTIPLE OUTLET ADAPTER, CORD
REEL OR OUTLET-TYPE AIR FRESHENER. THE USE OF SUCH DEVICES MAY CREATE
A FIRE HAZARD. DO NOT PLUG MULTIPLE
DEVICES IN THE SAME OUTLET OR ON SAME CIRCUIT AS UNIT.
• FAULTY WALL OUTLET CONNECTIONS MAY CAUSE THE WALL OUTLET TO OVERHEAT. BE SURE THAT UNIT PLUG FITS TIGHTLY
INTO OUTLET BEFORE EACH USE. DURING USE, CHECK TO MAKE CERTAIN THE UNIT PLUG IS NOT OVERHEATING. IF NECESSARY
HAVE A QUALIFIED ELECTRICIAN CHECK AND/OR REPLACE THE WALL OUTLET. DO NOT USE THIS UNIT WITH ANY SOLID STATE
SPEED CONTROL DEVICES.
• Make certain that the power source conforms to the electrical requirements of the Unit.
• Extreme caution is necessary when any Unit is used by or near children or invalids. The Unit should not be left operating unattended. Never
leave children unattended when the unit is on or plugged in.
• This appliance has a polarized plug (one blade is wider than the other).
To reduce the risk of electric shock, this plug is intended to fit in a
polarized outlet only one way.
If the plug does not fit fully in the outlet, reverse the plug.
If it still does not fit, contact a qualified electrician.
Do not attempt to defeat this safety feature.
DO NOT use the Unit in areas where gasoline, paint, or flammable liquids are used or stored. DO NOT use Unit in locations where flammable
or explosive chemicals are stored, or in wet atmospheres.
• Do not operate any Unit with a damaged cord or plug or after the Unit malfunctions, or has been dropped or damaged in any manner.
To
disconnect Unit, turn the Unit OFF then remove the plug from the outlet.
• Always unplug Unit when not in use. Unplug power cord before servicing or moving the Unit.
Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock, fire, or damage
the Unit.
Do not block or tamper with the Unit in any manner while it is in operation.
• Do not block air intakes or exhaust in any manner.
Do not place on soft surfaces, like a bed, where openings may become blocked. Do not
depend on the on/off
switch as the sole means of disconnecting power when servicing or moving the unit. Always unplug the power cord.
Read all instructions before using this Heater.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, these instructions and warnings should always be
followed to reduce the risk of fire, electrical shock and injury to persons:
WARNING
CAUTION
• Always place the Unit on a stable, flat, level surface when operating, to avoid the chance of the Unit overturning.
Locate the Power Cord so the Unit or
other objects are not resting on it.
DO NOT run Power Cord under carpeting.
DO NOT cover Power Cord with throw rugs, runners, or similar coverings
as this may cause cord to overheat. Arrange Power Cord away from room traffic and where it will not be tripped over.
• This Unit is HOT when in use.
To avoid burns, do not let bare skin touch hot surfaces.
Always use handle when moving this Unit. Keep combustible
materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet (0.9 m) from the front of the Unit and keep them at least 1 foot
(0.3 m) from the sides and rear.
• This Unit is not intended for use in wet or damp locations. This Unit is not intended for use in bathrooms, laundry areas and similar indoor locations.
NEVER locate a Unit where it may fall into a bathtub or other water container.
• DO NOT use Unit outdoors.
• This Unit is not suitable for use in agricultural facilities including areas where livestock, poultry or other animals are confined. Please refer to National
Electric Code (NEC) Article 547-7 (2008), or applicable state or local codes or standards relating to electrical requirements for Agricultural Buildings.
THIS UNIT DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547-7 (2008).
• This Unit is not suitable for use in hazardous locations. Please refer to National Electric Code (NEC) Article 500 or applicable state or local codes or
standards relating to electrical requirements for Hazardous locations.
THIS UNIT DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 500
(2008).
NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communi-
cations. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/
TV technician for help. The user is cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the
user’s authority to operate this equipment.
Please contact Customer Service at 800-233-0268 Monday through Friday from 8am to 5pm EST for assistance.
WARNING
NEW 7/18
7
FH500ES
MODELO FH500
AUTO ECO
THERMOSTAT
(Figura 3)
Al presionar los botones (
) o (
) mientras está en cualquier función o
velocidad del Calefactor, se activará la función Auto Eco
.
1.
Para fijar una temperatura específica en la habitación, presione los bot-
ones (
) o (
) hasta la temperatura deseada. La pantalla ahora reflejará
el símbolo de Auto Eco
y la temperatura destellará. El Calefactor está
ahora en modo Auto Eco
.
2.
Cuando se alcance la temperatura en la cual desea establecer la uni-
dad, la temperatura fijada destellará varias veces y luego la pantalla
volverá a indicar la temperatura ambiente actual y cambiará grad-
ualmente a medida que cambie la temperatura ambiente. NOTA: La
pantalla de la temperatura no indica la temperatura del aire caliente
que emite el Calefactor.
3.
Una vez que la temperatura ambiente alcance 2 grados por encima de la
temperatura fijada, el calefactor se apagará. El Calefactor continuará op-
erando durante 15 segundos después de que el elemento se ha apagado.
4.
Si la temperatura ambiente es igual a la temperatura FIJADA, el calefactor
operará en calor BAJO.
5.
Si la temperatura ambiente es menos de la temperatura FIJADA en más
de 3 grados, el calefactor operará en calor ALTO.
Todo esto ocurre automáticamente con la tecnología Auto Eco
de Lasko.
Para desactivar la función Auto Eco
, apague el calefactor o presione el
botón (
).
NOTA: En el modo Auto Eco
, el Calentador mostrará la temperatura am-
biente actual en grados Fahrenheit. Presione los botones (
) y (
)
al mismo tiempo para mostrar los grados Celsius. Presione los
mismos dos botones juntos nuevamente para volver a mostrar los
grados Fahrenheit.
OSCILACIÓN
Con el unidad encendido, oprima el Botón de Oscilación (
) para activar y
desactivar la función de oscilación. La función de oscilación puede utilizarse
con cualquier modo de velocidad y/o de temporizador.
FUNCIÓN DE TEMPORIZADOR
(Figura 5)
La función de temporizador puede ser activada cuando la pantalla del
unidad está en cualquier función o velocidad.
Esta función le permite fijar
la cantidad de tiempo que el unidad estará funcionando antes de apagarse
automáticamente, de 1 hora a 8 horas. Presionar el
Botón de Temporizador
(
) aumentará la cantidad de tiempo en 1 hora cada vez que dicho botón
sea oprimido. Después que la pantalla refleje 8 horas, si presiona el
Botón
de Temporizador
(
) una vez más, se reiniciará el unidad para función
continua. La unidad se puede volver a encender presionando cualquiera
de los
Botones de Encendido
(
).
SISTEMA DE FILTRO EZCLICK™
Pulse el botón del Filtro EZclick™ para liberar la cubierta del filtro permanente.
Limpie el filtro con una aspiradora con cepillo, cada dos semanas; de esa
manera, ayudará a mantener el desempeño óptimo del filtro. Recuerde limpiar
el filtro antes de guardar la unidad al final de la temporada.
ENSAMBLAJE
1.
Cuidadosamente retire el unidad de la bolsa y de la caja de cartón. Para
facilitar el ensamblaje, apoye el unidad de modo tal que la parrilla frontal
y el panel de control apunten hacia arriba.
2. Introduzca el
Cable Eléctrico
a través del orificio grande en el ensam-
blaje de la
Base
. NOTA: El
Canal para el Cable
en la parte inferior de
la base debe quedar hacia la parte trasera del unidad.
(Figura 1)
3. Ensamble la
Base
al encajar el
Lado A y el Lado B
.
(Figura 1)
4. Conecte la
Base
a la parte inferior del unidad Mediante el uso de 4
Tornillos de Apriete Manual
, fije la
Base
al unidad.
(Figura 2)
Cable
Eléctrico
Canal
para el
Cable
Base Lado A
Base Lado B
Figura 1
Base
Tornillos de
Apriete Manual
Figura 2
FUNCIONAMIENTO
1. Coloque el Unidad sobre una superficie firme y plana. Los tacos de
plástico o hule, tales como las patas de esta unidad, pueden pegarse
a la superficie de los muebles y/o a los pisos de madera. La unidad
podría dejar un residuo capaz de oscurecer, manchar o dejar marcas
permanentes en el acabado de ciertas superficies de muebles,
incluyendo superficies de madera y/o pisos de madera.
2.
Conecte el cable a un tomacorriente de 120 Vca.
Asegúrese que el enchufe encaje
firmemente en el tomacorriente.
Cuando los enchufes quedan flojos dentro de los
tomacorrientes, podrían deslizarse parcial o completamente
fuera del tomacorriente con el menor movimiento del cable
adosado. Los tomacorrientes en este estado podrían
sobrecalentarse y representar un peligro de incendio grave;
si queda cubierto por una cortina o tela, el peligro de
incendio es todavía mayor.
3.
Cuando el unidad se conecte por primera vez, se oirá un “bip” y la
Luz
de Encendido
se encenderá indicando que hay electricidad en la unidad.
La
Luz de Encendido
permanecerá encendida hasta que el unidad sea
desconectado del tomacorriente eléctrico.
4. ENCIENDA el Calefactor oprimiendo el
Botón de Encendido del
Calefactor
(
).
5.
Al encender el Calefactor, la unidad estará en calor Alto (H3) (1 500 Watts).
(Figura 3)
6. Presione el
Botón de Modo de Calor
(
) para activar el calor Medio
(H2). Presione nuevamente para activar el calor Bajo (H1). Presione una
tercera vez para el Modo de Ventilador Calefactor (HF). Esto activa la
configuración de calor alto (H3) y la velocidad de ventilador superbaja
(F1) simultáneamente. Presione una cuarta vez para volver a activar el
calor Alto (H3).
7. Para APAGAR el Calefactor, presione el
Botón de Encendido del
Calefactor
(
) y desconecte el Calefactor del tomacorriente eléctrico.
8. ENCIENDA el Ventilador oprimiendo el
Botón de Encendido del
Ventilador
(
).
9.
Al encender el Ventilador, la unidad estará en Velocidad Alta (F4).
10. Presione el
Botón de Modo de Ventilador
(
) para activar el Velacidad
Media (F3). Presione nuevamente para activar el Bajo Velacidad (F2).
Presione una tercera vez para Súper Baja Velocidad (F1). Presione una
cuarta vez para volver a activar el Velocidad Alta (F4).
11. Para APAGAR el Ventilador, presione el
Botón de Encendido del
Ventilador
(
) y desconecte el unidad del tomacorriente eléctrico.
Figura 3
Figura 4
Figura 5