Lenovo ThinkCentre M57 Korean (User guide) - Page 52

MNP/V.42/V.42bis/V.44

Page 52 highlights

mIn &V &W_ %E_ +MS? +MS=? +MS=a,b,c,e,f &T6 &T7 &T8 &V0 &V1 &W0 &W1 %E0 %E1 bI Perform a Remote Digital Loopback Test Perform a Remote Digital Loopback Test and Self-Test Perform Local Analog Loopback Test and Self-Test Displays Active and Stored Profiles Display Last Connection Statistics Stores the active profile as Profile 0 Stores the active profile as Profile 1 Disable auto-retrain Enable auto-retrain Displays the current Select Modulation settings Displays a list of supported Select Modulation options Select modulation where: a=0, 1, 2, 3, 9, 10, 11, 12, 56, 64, 69; b=0-1; c=300-56000; d=300- 56000; e=0-1; and f=0-1. A, b, c, d, e, f default=12, 1, 300, 56000, 0, 0. Parameter "a" specifies the modulation protocol desired where: 0=V.21, 1=V.22, 2=V.22bis, 3=V.23, 9=V.32, 10=V.32bis, 11=V.34, 12=V.90,K56Flex,V.34......,56=K 56Flex, V.90,V.34......, 64=Bell 103, and 69=Bell 212. Parameter "b" specifies automode operations where: 0=automode disabled, 1= automode enabled with V.8/V.32 Annex A. Parameter "c" specifies the minimum connection data rate (300- 56000). Parameter "d" specifies the maximum connection rate (300-56000); Parameter "e" specifies the codec type (0= Law, and 1=A-Law). Parameter "f" specifies "robbed bit" signaling detection (0=detection disabled 1=detection enabled) MNP/V.42/V.42bis/V.44 mIn mIn %C_ &Q_ +DS44=0, 0 +DS44=3, 0 %C0 %C1 %C2 %C3 &Q0 &Q5 &Q6 44 gk 3m- bI Disable MNP Class 5 and V.42bis data compression Enable MNP Class 5 data compression only Enable V.42bis data compression only Enable MNP Class 5 and V.42bis data compression Direct data link only (same as \N1) V.42 data link with fallback options Normal data link only (same as \N0) Disable V.44 Enable V.44

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

´
µ
³
²
±
&T6
Perform a Remote Digital Loopback Test
&T7
Perform a Remote Digital Loopback Test and
Self-Test
&T8
Perform Local Analog Loopback Test and Self-Test
&V
&V0
Displays Active and Stored Profiles
&V1
Display Last Connection Statistics
&W_
&W0
Stores the active profile as Profile 0
&W1
Stores the active profile as Profile 1
%E_
%E0
Disable auto-retrain
%E1
Enable auto-retrain
+MS?
Displays the current Select Modulation settings
+MS=?
Displays a list of supported Select Modulation
options
+MS=a,b,c,e,f
Select modulation where:
a
=0, 1, 2, 3, 9, 10, 11,
12, 56, 64, 69;
b
=0-1;
c
=300-56000;
d
=300- 56000;
e
=0-1; and
f
=0-1.
A, b, c, d, e, f
default=
12, 1,
300, 56000, 0, 0.
Parameter
“a”
specifies the
modulation protocol desired where: 0=V.21, 1=V.22,
2=V.22bis, 3=V.23, 9=V.32, 10=V.32bis, 11=V.34,
12=V.90,K56Flex,V.34
......
,56=K
56Flex,
V.90,V.34
......
, 64=Bell 103, and 69=Bell 212.
Parameter “b” specifies automode operations where:
0=automode disabled, 1= automode enabled with
V.8/V.32 Annex A. Parameter
“c”
specifies the
minimum connection data rate (300- 56000).
Parameter
“d”
specifies the maximum connection
rate (300-56000); Parameter
“e”
specifies the codec
type (0= Law, and 1=A-Law). Parameter
“f”
specifies
“robbed
bit”
signaling
detection
(0=detection disabled 1=detection enabled)
MNP/V.42/V.42bis/V.44
µ
¸
³
´
µ
³
²
±
%C_
%C0
Disable MNP Class 5 and V.42bis data compression
%C1
Enable MNP Class 5 data compression only
%C2
Enable V.42bis data compression only
%C3
Enable MNP Class 5 and V.42bis data compression
&Q_
&Q0
Direct data link only (same as \N1)
&Q5
V.42 data link with fallback options
&Q6
Normal data link only (same as \N0)
+DS44=0, 0
Disable V.44
+DS44=3, 0
Enable V.44
44
±
²
±
±
²