Lexmark C540 Technical Reference - Page 18
Electrical specifications, Power requirements, Lexmark C54x nominal average power requirements - fuser
View all Lexmark C540 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Electrical specifications Printer model Electrical specification C54x low voltage models* C54x 100 volt model 100-127 V at 47-63 Hz, nominal 90-137 V, extreme 100 V at 47-63 Hz, nominal 90-110 V, extreme C54x high voltage models X546dtn MFP low voltage models X546dtn MFP high voltage models 220-240 V at 47-63 Hz (not available in all countries) 198-259 V, extreme 100-110 V (Japan) at 50-60 Hz, nominal 100-127 V at 50-60 Hz, nominal 90-110 V (Japan), extreme 90-137 V, extreme 220-240 V at 50-60 Hz, nominal (not available in all countries) 198-264 V, extreme * Using a 220-110 power converter with 110 V printer is not recommended. Warning-Potential Damage: Lexmark recommends that you do not use voltage converters with printers. Power requirements The following tables list the nominal average power requirements (including fuser power). Lexmark C54x nominal average power requirements Printing states C540n, C543dn Average power while printing continuously 1-sided (simplex) 2-sided (duplex) 480 W 340 W C544n, C544dn, C544dw, C544dtn 500 W 340 W Average power while idle Power Saver on Ready mode 18 W 34 W 18 W 36 W Max current while printing 100-110 V 110-127 V 220-240 V 8.7 A 7.6 A 4.1 A 8.7 A 7.6 A 4.1 A Note: Automatic duplex is not supported on the C540n and C544n. Printer specifications 18