Lexmark CX622 Forms and Bar Code Card P4.2 Technical Reference - Page 66
Range, Default value, Description, PostScript emulation
View all Lexmark CX622 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
Lexmark Confidential until announced PostScript emulation 66 Key /Units Range N/A Default value N/A Swiss Post bar code descriptors Key /Symbology Range N/A /HeightUnits 0-4 dec Description Optional. The value is 1/100 mm. Default value /SwissPostal 4 dec [int] /Height /WidthUnits /BarHeight must be: 653 dec • Greater than or equal to [int] 22 mm for module widths less than or equal to 0.45 mm (0.0177 in.) • Greater than or equal to 23 mm for module widths greater than 0.45 mm (0.0177 in.) 0-4 dec 2 dec [int] /Width /SpaceWidth /QuietZone 0.40-0.51 mm (0.0157-0.0200 in.) 0.40-0.51 mm (0.0157-0.0200 in.) [int int] 11 dec [int] 11 dec [int] [150 150] [array of integers] Description Identifies the bar code symbology. Specifies the units used for /BarHeight dimensions. 0-Use the default value. 1-1/300 in. units. 2-1/600 in. units. 3-1/1200 in. units. 4-1/720 in. units. Sets the bar height. Specifies the units used for /BarWidth and /SpaceWidth dimensions. 0-Use the default value. 1-1/300 in. units. 2-1/600 in. units. 3-1/1200 in. units. 4-1/720 in. units. If /WidthUnits is specified, then it takes precedence over /Units. Sets the bar width. The default value is 11/600 in. Sets the space width. The default value is 11/600 in. Optional. Sets the quiet zone in /Units.