Lexmark CX622 Forms and Bar Code Card P4.2 Technical Reference - Page 67
Arguments for one-dimensional bar codes, Intelligent Mail bar code descriptors
View all Lexmark CX622 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
Lexmark Confidential until announced PostScript emulation 67 Key /Units Range N/A Default value N/A Description Optional. The value is 1/600 in. Intelligent Mail bar code descriptors Key /Symbology /Units Type name name /Bars /Pitch /TrackerHeight /QuietZone /AscenderHeight int int int [int int] int /EmbedText name Range Default value Description N/A /IntelligentMail Identifies the bar code symbology. /300ths /600ths /1200ths /600ths The value is fixed. 38-63 dec 50 dec Sets the bar width in /Units. 20-24 dec 23 dec Sets the number of bars that print per inch. 100-160 dec 127 dec Sets the tracker height in /Units. [0-10000][0-10000] [150 150] The value is fixed. 100-210 135 Sets the ascender and descender offset in 1/100 mm. The total height of an ascender or descender is the sum of this field and the tracker height. /NoText /Under /Above /NoText Optional. Determines the HRT location printed with the bar code. Arguments for one-dimensional bar codes Key Type Default value Description /Symbology name N/A Required. For a list of valid values, see "Values for / Symbology key" on page 70. /Units N/A 1/600 in. Optional. Other valid values are 1/300, 1/1200, and 1/720 in., which also apply to height and width units for any one-dimensional symbology. 1 For the French Postal symbology, /Special and /PrintCheckChar are always set to true and cannot be changed to false.