Lexmark E312L Service Manual - Page 97
Connector Locations, Controller Board (model E310/E312)
View all Lexmark E312L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
4044-XXX 5. Connector Locations Controller Board (model E310/E312) Connector J1 Printhead U5 Operator Panel (signals at idle) J7 Engine/LVPS Board Pin No. Signal 1 N/A 2 Ground 1 Ground 2 +5 V dc 3 +5 V dc 4 N/A 5 +5 V dc 6 Ground 1 +5 V dc 2 +5 V dc 3 +5 V dc 4 +5 V dc 5 +5 V dc 6 +5 V dc 7 Ground 8 +5 V dc 9 +5 V dc 10 +5 V dc 11 Ground 12 +5 V dc 13 +5 V dc 14 +5 V dc Connector Locations 5-1
Connector Locations
5-1
4044-XXX
5.
Connector Locations
Controller Board (model E310/E312)
Connector
Pin No.
Signal
J1 Printhead
1
N/A
2
Ground
U5 Operator Panel
(signals at idle)
1
Ground
2
+5 V dc
3
+5 V dc
4
N/A
5
+5 V dc
6
Ground
J7 Engine/LVPS Board
1
+5 V dc
2
+5 V dc
3
+5 V dc
4
+5 V dc
5
+5 V dc
6
+5 V dc
7
Ground
8
+5 V dc
9
+5 V dc
10
+5 V dc
11
Ground
12
+5 V dc
13
+5 V dc
14
+5 V dc