Lexmark E323 Technical Reference - Page 76
Table 2-25, Job Control Continued, Unit of Measure, Universal Exit Language UEL / Start of PJL
UPC - 734646384216
View all Lexmark E323 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
2-64 PCL Table 2-25: Job Control (Continued) Command / Parameters Function / Result ESC&u#D Unit of Measure Range = (96, 100, 120, 144, 150, 160, 180, 200, 225, 240, 288, 300, 360, 400, 450, 480, 600, 720, 800, 900, 1200, 1440, 1800, 2400, 3600, 7200) Default = 300 units per inch Sets the size for the PCL Unit (units per inch). The Unit of Measure defines the unit used in the following commands: • Horizontal Cursor Position by PCL Unit (ESC*p#X) • Vertical Cursor Position by PCL Unit (ESC*p#Y) • Horizontal Rectangle Size by PCL Unit (ESC*c#A) • Vertical Rectangle Size by PCL Unit (ESC*c#B) The Unit of Measure also affects the rounding of character escapements and the Horizontal Motion Index. Note: This command does not affect the interpretation of binary raster data for bitmapped fonts, raster graphics, or user defined fill patterns. ESC%-12345X Universal Exit Language (UEL) / Start of PJL This command terminates the current printer language and allows switching into PJL. For more information, see "UNIVERSAL EXIT LANGUAGE Command" on page 3-2.