Table 2-21, Job Control Continued, Long-Edge Offset Registration, Unit of Measure
View all Lexmark T430 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 84 highlights
2-72 PCL Table 2-21: Job Control (Continued) Command / Parameters l ESC& #U Function / Result Long-Edge Offset Registration # = number of Decipoints Also known as Left Offset. Range = -32767 to 32767 Adjusts placement of logical page along the width of the physical page. (1 Decipoint = 1/720 inch) Default = 0 l ESC& #Z Short-Edge Offset Registration # = number of Decipoints Also known as Top Offset. Range = -32767 to 32767 (1 Decipoint = 1/720 inch) Adjusts placement of logical page along the length of the physical page. Default = 0 ESC&u#D Unit of Measure Range = (96, 100, 120, 144, 150, 160, 180, 200, 225, 240, 288, 300, 360, 400, 450, 480, 600, 720, 800, 900, 1200, 1440, 1800, 2400, 3600, 7200) Default = 300 units per inch Sets the size for the PCL Unit (units per inch). The Unit of Measure defines the unit used in the following commands: • Horizontal Cursor Position by PCL Unit (ESC*p#X) • Vertical Cursor Position by PCL Unit (ESC*p#Y) • Horizontal Rectangle Size by PCL Unit (ESC*c#A) • Vertical Rectangle Size by PCL Unit (ESC*c#B) The Unit of Measure also affects the rounding of character escapements and the Horizontal Motion Index. Note: This command does not affect the interpretation of binary raster data for bitmapped fonts, raster graphics, or user defined fill patterns. ESC% - 12345X Universal Exit Language (UEL) / Start of PJL This command terminates the current printer language and allows switching into PJL. For more information, see "UNIVERSAL EXIT LANGUAGE Command" on page 3-2.