LiftMaster 3900 3900PLD Manual - Page 16

Mounting And Wiring The Safety Reversing, Sensors, Aligning The Safety Reversing - door openers

Page 16 highlights

MOUNTING AND WIRING THE SAFETY REVERSING SENSORS • Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten safety reversing sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension (Figure 5). • Finger tighten the wing nuts. • Run the wires from both safety reversing sensors to the operator. Use insulated staples to secure wire to wall and ceiling. • Strip 7/16" (11 mm) of insulation from each set of wires. Separate white and white/black wires sufficiently to connect to the operator quick-connect terminals: white to white and white/black to grey (Figure 6). ALIGNING THE SAFETY REVERSING SENSORS • Plug in the operator. The indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct. The sending eye amber indicator light will glow regardless of alignment or obstruction. If the green indicator light in the receiving eye is off, dim, or flickering (and the invisible light beam path is not obstructed), alignment is required. • Loosen the sending eye wing nut and readjust, aiming directly at the receiving eye. Lock in place. • Loosen the receiving eye wing nut and adjust the safety reversing sensor until it receives the sender's beam. When the green indicator light glows steadily, tighten the wing nut. Figure 5 Wing Nut 1/4"-20 Carriage Bolt 1/4"-20x1/2" Lens TROUBLESHOOTING THE SAFETY REVERSING SENSORS 1. If the sending eye indicator light does not glow steadily after installation, check for: • Electric power to the operator. • A short in the white or white/black wires. These can occur at staples, or at operator connections. • Incorrect wiring between safety reversing sensors and operator. • A broken wire. 2. If the sending eye indicator light glows steadily but the receiving eye indicator light doesn't: • Check alignment. • Check for an open wire to the receiving eye. 3. If the receiving eye indicator light is dim, realign either sensor. NOTE: When the invisible beam path is obstructed or misaligned while the door is closing, the door will reverse. If the door is already open, it will not close. Figure 6 To CableTension Monitor Bell Wire Motor unit Bell Wire Connect Wire to Quick-Connect Terminals Sensor Connections WHT/RED WHT WHT/BLK WHT To Door Control Quick-Connect Terminals To insert or release wires, push in tab with screwdriver tip. Safety ReSvenrssionrg Sensor 16 Safety Reversing Sensor Sensor Invisible Light Beam Protection Area

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

16
Invisible Light Beam
Protection Area
Safety Reversing Sensor
Bell Wire
Bell Wire
Motor unit
Safety Reversing Sensor
Quick-Connect Terminals
WHT/BLK
WHT
WHT/RED
WHT
Sensor
Connections
To
CableT
ension Monitor
To
Door Control
Connect Wire to
Quick-Connect
Terminals
To insert or release wires, push
in tab with screwdriver tip.
Carriage Bolt
1/4"-20x1/2"
Lens
Wing Nut
1/4"-20
Figure 5
Figure 6
MOUNTING AND WIRING THE SAFETY REVERSING
SENSORS
Slide a 1/4"-20x1/2" carriage bolt head into the slot on
each sensor. Use wing nuts to fasten safety reversing
sensors to brackets, with lenses pointing toward each
other across the door. Be sure the lens is not obstructed
by a bracket extension (Figure 5).
Finger tighten the wing nuts.
Run the wires from both safety reversing sensors to the
operator. Use insulated staples to secure wire to wall
and ceiling.
Strip 7/16" (11 mm) of insulation from each set of wires.
Separate white and white/black wires sufficiently to
connect to the operator quick-connect terminals: white to
white and white/black to grey (Figure 6).
ALIGNING THE SAFETY REVERSING SENSORS
Plug in the operator. The indicator lights in both the
sending and receiving eyes will
glow
steadily
if wiring
connections and alignment are correct.
The
sending eye
amber indicator light will glow regardless
of alignment or obstruction. If the green indicator light in
the
receiving eye
is
off, dim, or flickering (and the invisible
light beam path is not
obstructed), alignment is required.
Loosen the
sending eye
wing nut and readjust, aiming
directly at the
receiving eye
. Lock in place.
Loosen the
receiving eye
wing nut and adjust the safety
reversing sensor until it receives the sender’s beam.
When the green indicator light
glows steadily
, tighten the
wing nut.
TROUBLESHOOTING THE SAFETY REVERSING
SENSORS
1. If the
sending eye
indicator light does not
glow steadily
after installation, check for:
Electric power to the operator.
A short in the white or white/black wires. These can
occur at staples, or at operator connections.
Incorrect wiring between safety reversing sensors and
operator.
A broken wire.
2.
If the sending eye indicator light
glows steadily
but the
receiving eye indicator light doesn’t:
Check alignment.
Check for an open wire to the
receiving eye
.
3.
If the
receiving eye
indicator light is dim, realign
either sensor.
NOTE:
When the invisible beam path is obstructed or
misaligned while the door is closing, the door will reverse.
If the door is already open, it will not close.