LiftMaster CAPXM Installation Manual - English French Spanish Manufactured Pri - Page 6

Door Board Overview, INPUT/OUTPUT, USED FOR, Relay Output 1, Wiegand Output 1, Supervised Input 1

Page 6 highlights

INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL Door Board Overview ThINe TCARPOXDMUhCasTaIOcoNmbinationPoRf aEc-cIeNssScToAnLtrLol inputs/outpuItNs oSnTtAheLDLoor Board that wNoErkTiWn cOoRnjKunction toAcoCnCtrEolSuSp tCo O2 NTROL access points. INTRODUCTION DOOR BOARD PRIMARY RELAY PRE-INSTALLAUXILIARY WIEGAND RELAY OUTPUT STIANTUSSTALL REQUEST TO EXIT Door 1 NETWORK ACCESS CONTROL INTRODUCTION PRE-INSTALL INSTALL NETWORK WIEGAND INPUT ACCESS CONTROL INTRODUCTION PRE-INSTALL INSTALL WINIPEUGTANND ETWORK ACCESS CONTROL STATUS AUXILIARY RELAY REQUEST TO EXIT PRIMARY RELAY Door 2 See page 17 for wiring diagram. INPUT/OUTPUT Relay Output 1 Relay Output 2 Wiegand Output 1 Wiegand Output 2 Supervised Input 1 Supervised Input 2 USED FOR Gated Operator, Door Strikes, Maglocks, Lights (for control-only power to be provided by external power supply), Alarm Shunt Standard 26-bit, 30-bit Wiegand, HID 37-bit with Facility Code, Transcore 37-bit, 32-bit MiFare Closed Door Sensor (Supervised EOL or unsupervised), Closed Limit Gate Sensor (Supervised EOL or unsupervised), Open Limit Gate Sensor (Supervised EOL or unsupervised) NOTE: Only the 26-bit Wiegand protocol is compatible in UL installations. 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

6
PRE-INSTALL
NETWORK
INSTALL
ACCESS CONTROL
INTRODUCTION
Door Board Overview
The CAPXM has a combination of access control inputs/outputs on the Door Board that work in conjunction to control up to 2
access points.
See page 17 for wiring diagram.
INPUT/OUTPUT
USED FOR
Relay Output 1
Gated Operator, Door Strikes, Maglocks, Lights (for control-only power to be provided by external
power supply), Alarm Shunt
Relay Output 2
Wiegand Output 1
Standard 26-bit, 30-bit Wiegand, HID 37-bit with Facility Code, Transcore 37-bit, 32-bit MiFare
Wiegand Output 2
Supervised Input 1
Closed Door Sensor (Supervised EOL or unsupervised), Closed Limit Gate Sensor (Supervised EOL
or unsupervised), Open Limit Gate Sensor (Supervised EOL or unsupervised)
Supervised Input 2
NOTE:
Only the 26-bit Wiegand protocol is compatible in UL installations.
DOOR BOARD
Door 1
Door 2
PRIMARY
RELAY
AUXILIARY
RELAY
WIEGAND
OUTPUT
WIEGAND
INPUT
WIEGAND
INPUT
REQUEST
TO EXIT
PRIMARY
RELAY
AUXILIARY
RELAY
STATUS
REQUEST
TO EXIT
STATUS