LiftMaster CSW24V CSW24V Manual - Page 41

b Check operation of CLOSE EYES/Interrupt Loop detector, Quick Close not, working correctly.

Page 41 highlights

TROUBLESHOOTING FAULT Quick Close not working correctly. Anti-Tailgating not working correctly. AUX Relay not working correctly. POSSIBLE CAUSES a) Quick Close setting incorrect b) CLOSE EYES/Interrupt loop detector or loop wire defective c) Defective Expansion board a) Anti-Tail setting incorrect b) CLOSE EYES/Interrupt loop detector or loop wire defective c) Defective Expansion board a) AUX Relay setting incorrect b) AUX Relay wiring incorrect c) Defective Expansion board TROUBLESHOOTING CHART CORRECTIONS a) Check that Quick Close setting is ON b) Check operation of CLOSE EYES/Interrupt Loop detector c) Replace defective Expansion board a) Check that Anti-Tail setting is ON b) Check operation of CLOSE EYES/Interrupt Loop detector c) Replace defective Expansion board a) Check AUX Relay switches settings b) Check that wiring is connected to either N.O. and COM or to N.C. and COM. c) Set AUX Relay to another setting and test. Replace defective expansion board. 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

39
TROUBLESHOOTING CHART
TROUBLESHOOTING
FAULT
POSSIBLE CAUSES
CORRECTIONS
Quick Close not
working correctly.
a) Quick Close setting incorrect
b)
CLOSE EYES/Interrupt loop detector or loop
wire defective
c) Defective Expansion board
a) Check that Quick Close setting is ON
b) Check operation of CLOSE EYES/Interrupt Loop detector
c) Replace defective Expansion board
Anti-Tailgating not
working correctly.
a) Anti-Tail setting incorrect
b)
CLOSE EYES/Interrupt loop detector or loop
wire defective
c) Defective Expansion board
a) Check that Anti-Tail setting is ON
b) Check operation of CLOSE EYES/Interrupt Loop detector
c) Replace defective Expansion board
AUX Relay not
working correctly.
a) AUX Relay setting incorrect
b) AUX Relay wiring incorrect
c) Defective Expansion board
a) Check AUX Relay switches settings
b) Check that wiring is connected to either N.O. and COM or to N.C. and COM.
c) Set AUX Relay to another setting and test. Replace defective expansion board.