LiftMaster H J- LOGIC 3 Manual - Page 17
Failsafe Wiring Types, Self-monitoring Safety Device Options
View all LiftMaster H manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
PROGRAMMING FAILSAFE WIRING TYPES TYPE TS Momentary contact to open, close, and stop with open override and Timer To Close. Every device that causes door to open, including a reversing device, activates the Timer To Close. Auxiliary controls can be connected to open input to activate the Timer To Close. If the timer has been activated, the open button and radio control can recycle the timer. The stop button will deactivate the Timer To Close until the next command input. The Timer To Close will function from the programmable mid stop with this wiring type. Compatible with 3-Button Station, 1-Button Station and 1- and 3-Button Remote Controls. (NOTE: Requires Optional self monitoring photo eyes to operate.) T Momentary contact to open, close, and stop, with open override and Timer To Close. Every device that causes the door to open, except a reversing device, activates the Timer To Close. Auxiliary controls can be connected to open input to activate the Timer To Close. If the Timer To Close has been activated, the open button and radio control can recycle the timer. The stop button will deactivate the timer until the next command input. The Timer to Close will function from the programmable mid stop with this wiring type. Compatible with 3-Button Station, 1-Button Station and 1- and 3-Button Remote Controls. (NOTE: Requires Optional self monitoring photo eyes to operate.) FSTS Momentary button contact for open, close and stop programming. Radio controls allowing open, close and stop. User set mid stop. User set Timer To Close. The single button station opens the door to the full open limit bypassing the mid stop and activates the Timer To Close, putting the operator in TS mode until the door reaches the down limit, or is stopped in travel. At which time the operator enters the B2 mode. Compatible with 3-Button Station, 1-Button Station and 1- and 3-Button Remote Controls. (NOTE: Requires Optional self monitoring photo eyes to operate this feature/wire type.) B2 Failsafe Same functions as B2. Self Monitoring safety device must be installed to operate door for each of the following failsafe wiring types. See Self Monitoring Safety Device Options. Compatible with 3-Button Station, 1-Button Station and 1- and 3-Button Remote Controls. D1 Failsafe Same functions as D1. Self Monitoring safety device must be installed to operate door for each of the following failsafe wiring types. See Self Monitoring Safety Device Options. Compatible with 2-Button Station and 2-Button Remote Control. E2 Failsafe Same functions as E2. Self Monitoring safety device must be installed to operate door for each of the following failsafe wiring types. See Self Monitoring Safety Device Options. Compatible with 3-Button Station and 3-Button Remote Control. SELF-MONITORING SAFETY DEVICE OPTIONS To use the operator in any of the Failsafe wiring modes, or Timer To Close wiring modes (TS, T, FSTS), a self monitoring safety device or CPS3 card with photo eyes or safety edges must be installed. RECOMMENDED SELF-MONITORING SAFETY DEVICES: CPS-L NEMA 1 Direct Connect Eyes CPS-LN4 NEMA 4 Direct Connect Eyes IMPORTANT NOTES: 1. External interlocks may be used with all functional modes. 2. Auxiliary devices are any devices that have only dry contacts. Examples: photocell, loop detector, pneumatic or electrical treadles, radio controls, one button stations, pull cords, etc. 3. Open override means that the door may be reversed while closing by activating an opening device without the need to use the stop button first. C2 Failsafe Same functions as C2. Self Monitoring safety device must be installed to operate door for each of the following failsafe wiring types. See Self Monitoring Safety Device Options. Compatible with 3-Button Station, 1-Button Station and 1- and 3-Button Remote Controls. 17