    programming and troubleshooting instructions inside cover of operator. inside the Electrical Box Right Hand Wall Mounted Operator 0Bracket Shelf Mounted Operator OPTIONAL Mounting Bracket P/N 08-9098 00 • Optimum Distance 0 12-15" C Optimum Distance 12-15" OAlign Sprockets Manual Operation
  • LiftMaster H | J-Quick Start Guide for L3 Manual - Page 2
    LED AFollow ALL local electrical codes 0 0 FAILSAFE B2 C2 D1 E2 ON-FAILSAFE Push and Release to Open (without Mid Stop programming) 0 0 Mid Stop - Programmable Open Override - Available When Photo Eyes or Edge Sensor are triggered, the Door will Reverse and Fully Open. Push and Holdto
  • 1
  • 2

i
ckStart
for the Riedel
H/J
door
operatorELITETm
SERIES
LOGIC
3.0
IMPORTANT:
This
QuickStart
is
intended
to
highlight
a
typical
installation.
These
instructions
are
not
intended
to
be
comprehensive.
Because
each
application
is
unique,
it
is
the
responsibility
of
the
purchaser,
designer,
installer
and
end
user
to
ensure
that
the
total
door
system
is
safe
for
its
intended
use.
Please
consult
the
manual
and/or
a
qualified
technician
for
further
information.
Operator
Mounting
Wall
Mount:
The
operator
should
generally
be
installed
below
the
door
shaft,
and
as
close
to
the
door
as
possible.
Bracket
Shelf
Mounting:
The
operator
may
be
mounted
either
above
or
below
the
door
shaft.
NOTE:
The
optimum
distance
between
the
door
shaft
and
operator
drive
shaft
is
between
12"-
15".
0
Place
door
sprocket
on
the
door
shaft.
Do
not
insert
the
key
at
this
time.
Place
drive
sprocket
on
the
appropriate
side
of
the
operator.
Do
not
insert
the
key
at
this
time.
0
Wrap
chain
drive
around
door
sprocket
and
join
roller
chain
ends
together
with
master
link.
0
Raise
operator
to
approximate
mounting
position
and
position
chain
over
operator
sprocket.
Raise
or
lower
operator
until
the
chain
is
taut
(not
tight).
Make
sure
the
operator
output
shaft
is
parallel
to
door
shaft
and
sprockets
are
aligned.
When
in
position,
secure
the
operator
to
wall
or
mounting
bracket.
0
Align
sprockets,
insert
key
into
keyway,
and
secure.
0
Place
hand
chain
around
hand
chain
wheel
.
0
Run
the
power
wires
through
the
power
wiring
conduit
hole
in
the
electrical
box
enclosure.
Connect
the
power
to
the
operator.
Connect
the
earth
ground
to
the
chassis
ground
screw
in
the
electrical
box
enclosure.
Follow
ALL
local
electrical
codes.
D
Adjust
the
limit
switches
to
open
and
close
door
properly.
Make
sure
the
limit
nuts
are
positioned
between
the
limit
switches
before
proceeding
with
adjustments.
Remove
cotter
pin
from
nut
on
the
clutch
shaft.
Back
off
clutch
nut
until
there
is
very
little
tension
on
the
clutch
spring.
Tighten
clutch
nut
gradually
until
there
is
just
enough
tension
to
permit
the
operator
to
move
the
door
smoothly
but
to
allow
the
clutch
to
slip
if
the
door
is
obstructed.
When
the
clutch
is
properly
adjusted,
it
should
generally
be
possible
to
stop
the
door
by
hand
during
travel
.
Reinstall
cotter
pin
when
finished.
e
Radio
programming
and
troubleshooting
instructions
inside
cover
of
operator.
Right
Hand
Wall
Mounted
Operator
0
C
inside
the
Electrical
Box
0115
V
PH.
1
Power
Connection
NEG
I
L1
L2
Chassis
Ground
Follow
ALL
local
electrical
codes.
Power
wiring
ONLY!
Limit
Switches
©
Retainin
©
°
Qos
4
.
0
ate
Limit
Nuts
ovo
°
osts
CLOSE
OPEN
Push
Direction
Limit
Nut
Will
Move
During
Travel
Optimum
Distance
12-15"
0
Bracket
Shelf
Mounted
Operator
OPTIONAL
Mounting
Bracket
P/N
08-9098
00
OAlign
Sprockets
Optimum
Distance
12-15"
Be
sure
door
sprocket
is
properly
aligned
with
drive
before
securing
to
the
shaft.
Chain
Keeper
(4"
above
floor)
Manual
Operation
e
This
operator
has
provisions
for
manually
operating
the
door
in
case
of
emergency
or
power
failure.
This
includes
both
a
floor
level
disconnect
chain
to
disconnect
the
door
from
the
door
operator
and
a
disconnect
chain
with
manual
hoist
to
electrically
disable
the
operator
controls.
Turn
off
power
to
the
operator
BEFORE
manually
operating
your
door.
0
To
operate
the
hoist,
pull
the
disconnect
chain
(small
chain)
to
engage
the
hoist
mechanism.
The
disconnect
chain
may
be
locked
in
position
by
slipping
the
end
through
the
keyhole
of
the
chain
keeper
mounted
on
the
wall
.
Operate
the
door
in
the
desired
direction
by
pulling
on
one
side
or
the
other
of
the
continuous
loop
hoist
chain
(large
chain).
The
disconnect
chain
must
be
released
from
the
chain
keeper
before
the
door
will
operate
again
electrically.
0
For
manual
operation,
pull
the
floor
level
disconnect
chain
and
secure
in
the
disengaged
position
by
slipping
the
end
through
the
keyhole
bracket
mounted
on
the
wall.
If
an
emergency
egress
device
is
used,
pull
handle
to
disengage
operator
from
door.
The
door
may
now
be
pushed
up
or
pulled
down
manually.
Release
the
disconnect
chain
to
operate
the
door
again
electrically.
Turn
off
power
to
the
operator
BEFORE
manually
operating
your
door.
°Electrical
Interlock
with
Hoist
0
Chain
Keeper
(with
pad
locking
provisions)
Mount
Chain
Keeper
4'
above
floor
°Manual
Disconnect
Keyhole
Bracket
14
AWG
Minimum