    & RSL12VH™ VEHICULAR SLIDE GATE OPERATOR INSTALLATION MANUAL CSASOEEPALCCAAESSBORRILESE. Your model may look different than the model illustrated in this manual. STOP IMPORTANT NOTE: The gate operation may be limited until the battery is fully charged. THIS PRODUCT IS TO BE INSTALLED AND SERVICED
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 2
    Mode Entrapment Protection Devices OPERATION AND MAINTENANCE Reset Switch Remote Control Sleep Mode Maintenance Battery Drive Chain TROUBLESHOOTING Diagnostic Error Codes Chart Troubleshooting Chart Wiring Diagram ACCESSORIES WARRANTY SAFETY » SAFETY SYMBOL AND SIGNAL WORD REVIEW When you see these
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 3
    GATE OPERATOR ENTRAPMENT PROTECTION UL325 Classification CLASS I CLASS II Slide Gate Operator Primary Type Secondary Type A B1 or B2 In order to complete a proper installation the open and close directions of gate travel. • Type A • Type B1 • Type B2 - Inherent (built into the operator)
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 4
    Posts • Guards for Exposed Rollers • Screen Mesh • Instructional and Precautionary Signage 4. Install the gate operator only when: a. The operator is appropriate for the construction and the usage class of the gate. b. All openings of a horizontal slide gate are guarded or screened from the bottom
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 5
    guide, refer to ASTM F2200 for panel types. 1.5 An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator. 3.2 The following provisions shall apply to Class IV vehicular horizontal slide gates: 1.6 A gate latch shall not be installed
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 6
    LSoaofepty Inside Property CONTACT SENSORS (EDGE SENSORS) Use edge sensor models G65MG0204, G65MG0205, G65MGR205, or G65MGS205 (2-wire, non-monitored). Edge sensor for open cycle Edge sensor for open cycle Edge sensor for open cycle Edge sensor for close cycle Edge sensor for close cycle
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 7
    access through openings anywhere the gate may travel. • Mount controls at least 6 feet (1.8 m) from the gate or ANY moving part of the gate. • Install Warning signs on EACH side of gate in PLAIN VIEW. Permanently secure each Warning sign in a suitable manner using fastening holes. • This operator is
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 8
    batteries. • SAVE THESE INSTRUCTIONS. • ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment. TROUBLESHOOTING To protect against fire and electrocution: • DISCONNECT power and battery BEFORE installing or servicing operator
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 9
    chain is required. 40 feet (Dual Gate) -20°C to 40°C (-4°F to 104°F) without Heater -40°C to 40°C (-40°F to 104°F) with Heater 16-3/5" 16-4/5" MOUNTING FOOTPRINT Control Board Fuse: 30 Amp (2) CARTON INVENTORY • Operator • Transformer • Documentation Packet • Battery 12 Vdc 7AH (1) .63" 7.49
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 10
    to check the following: • Gate is constructed and installed according to ASTM F2200 standards • Gate fits specifications of operator • National and local building codes • Earth ground rod • UL approved conduit for low and high voltage • Mounting considerations post or pad • Operator placement SAFETY
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 11
    » DOEPTEERRAMTOINREALTOTCAACTHIMONENFTOR CONCRETE PAD AND OPERATOR + CONCRETE PAD AND DETERMINE LOCATION FOR CONCRETE PAD AND OPERATOR 1 The gate operator should be installed near the front roller of the gate or near the back of the gate (in the OPEN position). The space between the gate and the
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 12
    not grounded properly the range of the remote 1controls will be reduced. Install the earth ground rod within 3 feet of the operator. 2 Attach the ground wire to the ground terminal on the control board. 11 2 4 5 3 2 OVLD AC PWR /SOLAR 2 12 gauge copper wire 1 Check national and local codes for
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 13
    or garage. Run low voltage wire between the transformer and the operator. 2 Connect the wires from the transformer to the AC PWR/SOLAR terminal located on the control board. 3 Plug the transformer into the external receptacle. CHGR OVLD CTRL 2 AC PWR /SOLAR 1 14.5 Vac COM 13.5 Vac 3 12
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 14
    WIRING » POWER WIRING + CONNECT BATTERIES POWER WIRING SOLAR PANEL (NOT PROVIDED. SEE ACCESSORIES.) 3 The solar panel(s) must be located in an open area clear of obstructions and shading for the entire day. The gate operator is not supported in northern climates where temperatures reach below
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 15
    WH YL BL RD GATE 2 2 PRIMARY OPERATOR GATE 1 BR GR WH YL BL RD ACCESSORY POWER 12 V BR GR WH YL BL RD GATE 2 7 ON OFF LOCK / BIPART DELAY Battery from secondary operator Battery from primary operator SECONDARY OPERATOR GATE 1 BR GR WH YL BL RD Gate 1 SECONDARY CONTROL BOARD NOT USED
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 16
    a combination of buttons on the control board. The specific buttons used for programming depends on which side of the gate the primary operator is installed and how many operators the installation includes. SET OPEN LIMIT GATE 1 SET CLOSE LIMIT LEARN LIMITS GATE 2 BEFORE programming the limits
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 17
    The control board will beep and the SET CLOSE LIMITS LED will stop blinking. Programming is now complete. If the SET OPEN LIMIT LED continues to blink, repeat programming. If the problem continues, see below. Test the limits by pressing the SINGLE BUTTON to open and close the gate. 1 ProInpseirdtye
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 18
    needed. 6 When gate is in the desired CLOSED position, press and release the LEARN LIMITS button. The control board will beep and the SET CLOSE LIMITS LED will stop blinking. Programming is now complete. If the SET OPEN LIMIT LED continues to blink, repeat programming. If the problem continues, see
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 19
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 20
    button to move the left operator to the desired OPEN position. When the gate is in the desired position, release the button. NOTE: The GATE 2 right and left buttons can be used to jog the gate back and forth as needed. 5 Press and release the LEARN LIMITS button. The control board will beep and the
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 21
    to open and close the gate. 2 If the gate stops or reverses before reaching the fully open or closed position increase the force by turning the force control slightly. On dual gate applications the force will require a higher setting because it is affecting two motors instead of one. 3 Run operator
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 22
    + ALTERNATE RADIO RECEIVER INSTALLATION A combined total of 50 remote controls and keyless entry PINs can be programmed to the operator. For highest level of security, we recommend the Security✚® line of products. Refer to Accessories. TO ADD OR REPROGRAM A REMOTE CONTROL (NOT PROVIDED) 1 Press
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 23
    batteries BEFORE servicing the operator. PARTY MODE If the Timer-to-Close feature is enabled and you would like the gate to remain open, open the gate fully, then toggle the reset switch. The next command given by a LiftMaster remote control or SINGLE BUTTON on the control board will close the gate
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 24
    to be reset before it will resume normal operation. NON-CONTACT SENSORS (12 VDC PHOTOELECTRIC SENSORS) Photoelectric sensor model 50-220. 1 Connect the non-contact sensor wires to either the OPEN PHOTO or CLOSE PHOTO terminal on the control board. It is best to use failsafe photoelectric sensors
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 25
    on the primary operator. E REMOTE CONTROL Once the remote control has been programmed operator will operate as follows: When gate is in the closed position, activation of the remote control button will open the gate. During the open cycle another activation of the remote control will stop the
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 26
    MAINTENANCE Disconnect all power to the operator before servicing. DESCRIPTION External Entrapment Protection System Photoelectric Sensors Warning Signs Manual Disconnect Drive Chain Sprockets and Pulleys Gate Accessories Electrical Chassis Mounting Bolts Operator Batteries TASK Check and test for
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 27
    sure the jumper wire is connected between the COM and STOP input on the control board. Stop is an NC (normally closed) input. Battery voltage is below the recommended operating level. • Battery may not be properly charged. Disconnect all batteries and make sure AC power or solar power is connected
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 28
    . Disconnect the operator(s) and verify that the gate(s) slide easily. • Check the brown and green wires on J17 to ensure they are properly connected. If this did not solve the problem the RPM Module or control board may need to be replaced. Contact technical support. • Battery not connected. At
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 29
    » TROUBLESHOOTING CHART OPERATOR DOES NOT RESPOND TO COMMAND. GATE STOPS AND REVERSES IMMEDIATELY AFTER IT STARTS MOVING. • Antenna not connected. Verify the antenna and coaxial cable are properly connected to the control board. • Remote control not programmed. Refer to Programming Remote Control
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 30
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 31
    to the operator application. Model 29-NP712 (7 AMP-Hour Battery, 12 Vdc) Model A12330SGLPK (33 AMP-Hour Battery with Harness, 12 Vdc. Ideal for solar applications and extended battery backup) BATTERY HARNESS Required when a second 7AH battery is installed. Model K94-35225 SOLENOID GATE LOCK (LOW
  • LiftMaster RSL12V | RSL12V Installation Manual - Page 32
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

RSL12V
&
RSL12VH
VEHICULAR SLIDE GATE OPERATOR
INSTALLATION MANUAL
This model is for use on vehicular
passage gates ONLY and not intended
for use on pedestrian passage gates.
This model is intended for use in
Class I and Class II vehicular slide
gate applications.
UL325
compliant
UL991
compliant
THIS PRODUCT IS TO BE
INSTALLED AND SERVICED BY
A TRAINED GATE SYSTEMS
TECHNICIAN ONLY.
Visit www.liftmaster.com to
locate a professional installing
dealer in your area.
Your model may look different than the model illustrated in this manual.
SOLAR
CAPABLE
SEE ACCESSORIES.
SOLAR
CAPABLE
IMPORTANT NOTE:
The gate operation may be
limited until the battery is fully charged.
STOP