Step 7 Dual Gates Only, Dual Gates Only

Page 16 highlights

INSTALLATION STEP 7 DUAL GATES ONLY There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and wireless communication simultaneously. Wired dual gate applications will have a longer battery standby time than wireless applications. WIRELESS DUAL GATES TO ACTIVATE THE WIRELESS FEATURE: 1. Choose an operator to be the network primary operator. All wireless accessories will need to be programmed to the primary operator. NOTE: We recommend that all accessories and board configurations are set on the primary operator. 2. Press and release the LEARN RADIO button on the primary operator. The green XMITTER LED will light. 3. Press and release the LEARN RADIO button again on the primary operator. The yellow NETWORK LED will light. 4. Press and release the OPEN test button to assign this operator as network primary. 5. Press and release the LEARN RADIO button on the second operator. The green XMITTER LED will light. AC & BATT FAIL 6. Press and release the LEARN RADIO button again on the second BACKDRIVE operator. The yellow NETWORK LED will light. 7. Press and release the CLOSE test button to assign this operator as network second. Both operators will beep and the yellow NETWORK LEDs will turn off indicating programming is successful. COM LINK BA TO DEACTIVATE THE WIRELESS FEATURE: 1. Press and release the LEARN RADIO button on either operator. The green XMITTER LED will light. 2. Press and release the LEARN RADIO button again on the same operator. The yellow NETWORK LED will light. 3. Press and hold the LEARN RADIO button for 5 seconds. The yellow NETWORK LED will blink (operator will beep) then turn off indicating successful deactivation. Repeat the steps for the other operator. 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

15
INSTALLATION
STEP 7
DUAL GATES ONLY
There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and
wireless communication simultaneously.
Wired dual gate applications will have a longer battery standby time than wireless applications.
WIRELESS DUAL GATES
TO ACTIVATE THE WIRELESS FEATURE:
1.
Choose an operator to be the network primary operator. All wireless
accessories will need to be programmed to the primary operator.
NOTE:
We recommend that all accessories and board configurations
are set on the primary operator.
2.
Press and release the LEARN RADIO button on the primary operator.
The green XMITTER LED will light.
3.
Press and release the LEARN RADIO button again on the primary
operator. The yellow NETWORK LED will light.
4.
Press and release the OPEN test button to assign this operator as
network primary.
5.
Press and release the LEARN RADIO button on the second operator.
The green XMITTER LED will light.
6.
Press and release the LEARN RADIO button again on the second
operator. The yellow NETWORK LED will light.
7.
Press and release the CLOSE test button to assign this operator as
network second.
Both operators will beep and the yellow NETWORK LEDs will turn off
indicating programming is successful.
TO DEACTIVATE THE WIRELESS FEATURE:
1.
Press and release the LEARN RADIO button on either operator. The
green XMITTER LED will light.
2.
Press and release the LEARN RADIO button again on the same
operator. The yellow NETWORK LED will light.
3.
Press and hold the LEARN RADIO button for 5 seconds. The yellow
NETWORK LED will blink (operator will beep) then turn off indicating
successful deactivation.
Repeat the steps for the other operator.
AC & BATT FAIL
BACKDRIVE
COM
LINK
B