Lowrance Elite-4x CHIRP Ice Machine Elite-x Series Operation Manual - EN - Page 19

Sensitivity, Colorline, Auto Sensitivity, Range, Custom Range - Upper and Lower Limits

Page 19 highlights

Sensitivity Controls the level of detail shown on the display. Too much detail will clutter the screen. If Sensitivity is set too low, desired echoes may not be displayed. NOTE: You can make minor (+/-40%) changes to sensitivity with Auto Sensitivity turned on. You will have to turn it off to make significant adjustments. Colorline Helps distinguish fish or structure from the bottom by showing hard returns as light colors and soft returns as darker colors. A lower colorline setting will display only the hardest returns, shown in light colors. Auto Sensitivity Keeps sensitivity at a level that works well under most conditions, reducing the needs for adjustments. Auto Sensitivity is turned on by default. Range Selects the deepest range shown on the display. Range settings display the section of the water column from the water surface to the selected depth range. If you select too shallow a depth range, the unit will not be able to lock onto the bottom. Custom Range - Upper and Lower Limits Used to select the upper limit and lower limit of a section of the water column. That allows you to view a section of the water column that does not include the water surface or the bottom. Upper and lower limits must be at least 6.5 ft (2m) apart. Sonar Operation | Elite X series 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

16
Sonar Operation |
Elite X series
Sensitivity
Controls the level of detail shown on the display.
Too much detail will clutter the screen. If Sensitivity
is set too low, desired echoes may not be displayed.
Colorline
Helps distinguish fish or structure from the
bottom by showing hard returns as light colors
and soft returns as darker colors. A lower colorline
setting will display only the hardest returns,
shown in light colors.
Auto Sensitivity
Keeps sensitivity at a level that works well under
most conditions, reducing the needs for adjust-
ments. Auto Sensitivity is turned on by default.
NOTE:
You can make minor (+/-40%)
changes to sensitivity with Auto Sensitivity
turned on. You will have to turn it off to
make significant adjustments.
Range
Selects the deepest range shown on
the display. Range settings display the
section of the water column from the
water surface to the selected depth
range.
If you select too shallow a depth range, the unit will
not be able to lock onto the bottom.
Custom Range — Upper and Lower Limits
Used to select the upper limit and lower limit of
a section of the water column. That allows you to
view a section of the water column that does not
include the water surface or the bottom. Upper